Inflammatory reactions after vascular prosthesis implantation: A comparison of gelatin-sealed and unsealed dacron prostheses

  • Original Articles
  • Published:
Surgery Today Aims and scope Submit manuscript

Abstract

Despite widespread use of the gelatin-sealed knitted Dacron prosthesis (GDP) in clinical practice owing to its zero porosity, the biological impacts of this graft are still controversial. We conducted a randomized controlled study on 50 patients undergoing abdominal aortic aneurysm repair to evaluate the inflammatory reaction to GDP (n=25) and unsealed knitted Dacron prostheses (UDP, n=25). There were no significant differences in the mean age, size of the aneurysm, operative time, blood loss, or transfusion requirements between the GDP and UDP groups. During the first 7 postoperative days (PODs), slight fever and leukocytosis were noticed in both groups. Significant differences in maximum body temperature, leukocyte count, and plasma C-reactive protein concentration were observed between the GDP and VDP groups on POD 14: 37.2±0.5°C vs 36.9±0.3°C (P=0.019), 8,151±1,788/μl vs 6,914±1,501/μl (P=0.015), and 32.6±27.5mg/l vs 19.0±15.8mg/l (P=0.048), respectively. By POD 21, however, there were no detectable differences in these variables. Thus, we concluded that GDP caused an inflammatory reaction in the 2nd week after implantation, but ultimately there were no significant differences from UDP by the 3rd week.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Vohra R, Drury JK, Dhapiro D, Shenkin A, Pollock JG (1987) Sealed versus unsealed knitted Dacron prostheses: a comparison of the acute phase protein response. Ann Vasc Surg 1:548–551

    Google Scholar 

  2. Drury JK, Ashton TR, Cunningham JD, Maini R, Pollock JG (1987) Experimental and clinical experience with a gelatin-impregnated Dacron prosthesis. Ann Vasc Surg 5:542–547

    Google Scholar 

  3. Ohshima N, Yamada T, Nakahara H, Tanabe S, Irie Y, Katayama Y, Sano E, Nagasawa S, Kiyama H, Murai N, Yokoyama M (1994) Sealed versus unsealed Dacron knitted prosthesis: comparison of intraoperative blood loss and inflammatory response (in Japanese with English abstract). Jinko Zoki (Jpn J Artif Organs) 23:825–828

    Google Scholar 

  4. Nishina T, Okabayashi H, Shimada I, Ohno N, Minatoya K, Kameyama T, Soga Y (1994) Experience of gelseal triaxial for abdominal aortic aneurysm (in Japanese with English abstract). Jinko Zoki (Jpn J Artif Organs) 23:829–831

    Google Scholar 

  5. Nonami Y, Sakamoto H, Satoh K, Nishimori H, Ogoshi S (1994) Clinical experience with a gelatin-sealed Dacron prosthesis in the axillobifemoral bypass and their perioperative problems (in Japanese with English abstract). Jinko Zoki (Jpn J Artif Organs) 23:821–824

    Google Scholar 

  6. Pepys MB, Baltz ML (1983) Acute phase proteins with special reference to C-reactive protein and related proteins and serum amyloid A protein. Adv Immunol 34:141–212

    Google Scholar 

  7. Pollock JG, Drury JK, Cuscheri RJ, Guidion R, Maini R (1986) New knitted Dacron prosthesis: Experimental and clinical results. Rev Bras Angiol 16:113–121

    Google Scholar 

  8. Guidoin R, Marceau D, Rao TJ, King M, Merhi Y, Roy P, Martin L, Duval M (1987) In vitro and in vivo characterization of an impervious polyester arterial prosthesis: the gelseal triaxial graft. Biomaterials 8:433–441

    Google Scholar 

  9. Reid DB, Pollock JG (1991) A prospective study of 100 gelatin-sealed aortic grafts. Ann Vasc Surg 5:320–324

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Utoh, J., Miyauchi, Y., Goto, H. et al. Inflammatory reactions after vascular prosthesis implantation: A comparison of gelatin-sealed and unsealed dacron prostheses. Surg Today 26, 258–261 (1996). https://doi.org/10.1007/BF00311584

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00311584

Key Words

Navigation