Advertisement

Asian Journal of Civil Engineering

, Volume 20, Issue 2, pp 187–196 | Cite as

Parametric study on cylindrical water tanks by varying their aspect ratios

  • Abhyuday TitikshEmail author
Original Paper
  • 14 Downloads

Abstract

Safe drinking water is one of the basic elements for humans to sustain healthy life. Reinforced concrete overhead water tanks are widely used to provide safe drinking water. Most water supply systems in developing countries, such as India, where urbanizing is increasing day by day, rely on overhead storage tanks and hence there is need to construct more number of water tanks. Earlier design of water tanks was done using the working stress method given in IS: 3370 1965. This method leads to thicker and heavily reinforced sections. The use of limit state method of design was then adopted in the revised code IS 3370: 2009 and provision for checking the crack width was included in the code. This study is carried out to analyze the cost of overhead water tanks of a fixed capacity, having different heights and diameters so as to determine the most economical height to diameter (H/D) ratio to be adopted in the design of the tank. To optimize the results and check the accuracy of design, six circular water tanks of 350 kL, with top and bottom dome pattern, were designed by varying H/D ratio from 0.50 to 0.75 in STAAD.Pro. After assuring the safety of all the structures, further analysis is done to calculate the cost-effectiveness of the structures by comparing the approximate total cost of materials. It was found that the aspect ratio (H/D) of 0.60 led to the most efficient design.

Keywords

STAAD.Pro Water tank Aspect ratio Cost analysis Design 

Notes

Funding

No funding sources are available. The work reported here is an original independent research and has not been reported anywhere else. Plagiarism has been prevented to the best of the author’s knowledge and, whenever needed, necessary citations have been provided.

Compliance with ethical standards

Conflict of interest

The author states that there is no conflict of interest.

References

  1. ACI 350.3. (2001). Seismic design of liquid-containing concrete structures and commentary, ACI Committee 350. Farmington Hills, MI: American Concrete Institute.Google Scholar
  2. Falguni, A., & Vanza, M. G. (2012). Structural control system for elevated water tank. International Journal of Advanced Engineering Research and Studies, I(III), 325–328.Google Scholar
  3. Godoy, L. A. (2002). Damage due to buckling in above ground storage tank. Mayaguez: University of Puerto Rico.Google Scholar
  4. IS:1893 (Part I). (2002). Criteria for earthquake resistant design of structures. New Delhi: Bureau of Indian Standard.Google Scholar
  5. IS:3370 (Part I). (2009). General requirements, code of practice for concrete structures for the storage of liquids. New Delhi: Bureau of Indian Standard.Google Scholar
  6. IS:3370 (Part IV). (1967). Design tables, code of practice for concrete structures for the storage of liquids. New Delhi: Bureau of Indian Standard.Google Scholar
  7. IS:456. (2000). Plain and reinforced concrete—Code for practice. New Delhi: Bureau of Indian Standard.Google Scholar
  8. IS:875. (2002). Code of practice for design load. New Delhi: Bureau of Indian Standard.Google Scholar
  9. Jabar, A. M., & Patel, H. S. (2012). Seismic behavior of RC elevated water tank under different staging pattern and earthquake characteristics. International Journal of Advanced Engineering Research and Studies, I(III), 293–296.Google Scholar
  10. Jain, S. K., & Medhekar, M. S. (1993). Proposed provisions for a seismic design of liquid storage tanks: Part I—Codal provisions. Journal of Structural Engineering, 20(3), 119–128.Google Scholar
  11. Jain, S. K., & Medhekar, M. S. (1994). Proposed provisions for a seismic design of liquid storage tanks: Part II—Commentary and examples. Journal of Structural Engineering, 20(4), 167–175.Google Scholar
  12. Jain, S. K., & Sameer, U. S. (1990). Seismic design of frame staging for elevated water tank. 9th Symposium on Earthquake Engineering (9SEE-90), Roorkey, December 14–16 (Vol. 1).Google Scholar
  13. Jaiswal, O. R., Rai, D. C., & Jain, S. K. (2004a). Codal provisions on design seismic forces for liquid storage tanks: A review. Report No. IITK-GSDMA-EQ-01-V1.0. Kanpur: Indian Institute of Technology Kanpur.Google Scholar
  14. Jaiswal, O. R., Rai, D. C., & Jain, S. K. (2004b). Codal provisions on seismic analysis of liquid storage tanks: A review. Report No. IITK-GSDMA-EQ-04-V1.0. Kanpur: Indian Institute of Technology Kanpur.Google Scholar
  15. Kumar, A. (2006). Ductility analysis of R.C.C.(O.H.T) design as per IS:3370 (Part-II). M-Tech Thesis.Google Scholar
  16. Lodhi, R. S., & Garg, V. (2014). Design of Intze Tank in perspective of revision of IS: 3370. International Journal of Scientific Engineering and Technology (IJSET), 3(9), 1193–1197.Google Scholar
  17. Mohammed, H. J. (2011). Economical design of water concrete tanks. European Journal of Scientific Research, 49(4), 510–520.Google Scholar
  18. Rai, D. C. (2003). Performance of elevated tanks in Mw 7.7 Bhuj earthquake of January 26th, 2001. In International Journal of Advanced Engineering Research, Proc. Indian Acad. Sci. (Earth Planet. Sci.) (Vol. 112, No. 3, pp. 421–429).Google Scholar
  19. Rai, D. C., & Singh, B. (2004). Seismic design of concrete pedestal supported tanks. 13th World Conference on Earthquake Engineering, Vancouver, B.C, Canada August 1–6, 2004.Google Scholar
  20. STAAD Pro v8i. (2012). SELECT Series 4 User Manual.Google Scholar