Advertisement

Development of readout electronics for bunch arrival-time monitor system at SXFEL

  • Jin-Guo Wang
  • Bo LiuEmail author
Article
  • 20 Downloads

Abstract

A bunch arrival-time monitor (BAM) system, based on electro-optical intensity modulation scheme, is under study at Shanghai Soft X-ray Free Electron Laser. The aim of the study is to achieve high-precision time measurement for minimizing bunch fluctuations. A readout electronics is developed to fulfill the requirements of the BAM system. The readout electronics is mainly composed of a signal conditioning circuit, field-programmable gate array (FPGA), mezzanine card (FMC150), and powerful FPGA carrier board. The signal conditioning circuit converts the laser pulses into electrical pulse signals using a photodiode. Thereafter, it performs splitting and low-noise amplification to achieve the best voltage sampling performance of the dual-channel analog-to-digital converter (ADC) in FMC150. The FMC150 ADC daughter card includes a 14-bit 250 Msps dual-channel high-speed ADC, a clock configuration, and a management module. The powerful FPGA carrier board is a commercial high-performance Xilinx Kintex-7 FPGA evaluation board. To achieve clock and data alignment for ADC data capture at a high sampling rate, we used ISERDES, IDELAY, and dedicated carry-in resources in the Kintex-7 FPGA. This paper presents a detailed development of the readout electronics in the BAM system and its performance.

Keywords

Bunch arrival-time monitor (BAM) Shanghai Soft X-ray Free Electron Laser (SXFEL) Field-programmable gate array (FPGA) Signal conditioning High-speed analog-to-digital converter (ADC) 

References

  1. 1.
    M.W. Guetg, A.A. Lutman, Y. Ding et al., Generation of high-power high-intensity short X-ray free-electron-laser pulses. Phys. Rev. Lett. 120, 014801 (2018).  https://doi.org/10.1103/physrevlett.120.014801 CrossRefGoogle Scholar
  2. 2.
    M. Dunne, X-ray free-electron lasers light up materials science. Nat. Rev. Mater. 3, 290–292 (2018).  https://doi.org/10.1038/s41578-018-0048-1 CrossRefGoogle Scholar
  3. 3.
    Z.T. Zhao, C. Feng, K.Q. Zhang, Two-stage EEHG for coherent hard X-ray generation based on a superconducting linac. Nucl. Sci. Tech. 28, 117 (2017).  https://doi.org/10.1007/s41365-017-0258-z CrossRefGoogle Scholar
  4. 4.
    Z.T. Zhao, D. Wang, L.X. Yin et al., Shanghai soft X-ray free-electron laser facility. Chin. J. Lasers 46(1), 0100004 (2019).  https://doi.org/10.3788/cjl201946.0100004. (in Chinese) CrossRefGoogle Scholar
  5. 5.
    Z. Wang, C. Feng, Q. Gu et al., Generation of double pulses at the Shanghai soft X-ray free electron laser facility. Nucl. Sci. Tech. 28, 28 (2017).  https://doi.org/10.1007/s41365-017-0188-9 CrossRefGoogle Scholar
  6. 6.
    M.H. Song, C. Feng, D.Z. Huang et al., Wakefields studies for the SXFEL user facility. Nucl. Sci. Tech. 28, 90 (2017).  https://doi.org/10.1007/s41365-017-0242-7 CrossRefGoogle Scholar
  7. 7.
    M. Altarelli, R. Brinkmann, M. Chergui et al., XFEL: The European X-ray free-electron laser-technical design report. DESY 2006-097. 097. 1-557. http://xfel.desy.de/localfsExplorer_read?currentPath=/afs/desy.de/group/xfel/wof/EPT/TDR/XFEL-TDR-final.pdf
  8. 8.
    N. Hartmann, G. Hartmann, R. Heider, Attosecond time–energy structure of X-ray free-electron laser pulses. Nat. Photonics 12, 215 (2018).  https://doi.org/10.1038/s41566-018-0107-6 CrossRefGoogle Scholar
  9. 9.
    Linac Coherent Light Source II (LCLS-II) Conceptual Design Report, SLAC, Design Report, 2011. https://portal.slac.stanford.edu/sites/lcls_public/lcls_ii/Published_Documents/CDR%20Index.pdf
  10. 10.
    R. Ganter, R. Abela, H. Braun et al., SwissFEL Conceptual Design Report, PSI, Design Report, 2010. http://www.lib4ri.ch/archive/nebis/PSI_Berichte_000478272/PSI-Bericht_10-04.pdf
  11. 11.
    R. Abela, P. Beaud, J.A. Bokhoven et al., Perspective: opportunities for ultrafast science at SwissFEL. Struct. Dyn. 4, 061602 (2018).  https://doi.org/10.1063/1.4997222 CrossRefGoogle Scholar
  12. 12.
    Z.Q. Geng, Beam-based optimization of SwissFEL low-level RF system. Nucl. Sci. Tech. 29, 128 (2018).  https://doi.org/10.1007/s41365-018-0460-7 CrossRefGoogle Scholar
  13. 13.
    C. J. Bocchetta, A. Abrami, E. Allaria et al., FERMI@Elettra Conceptual Design Report, Elettra, Design Report, 2007. https://www.elettra.trieste.it/files/Documents/FERMI%20Machine/Machine/CDR/FERMI_CDR_Ch01.pdf
  14. 14.
    S. B. Habib, D. Sikora, J. Szewinski et al., Development of uTCA hardware for BAM system at FLASH and XFEL. In Proceedings of MIXDES, Warsaw, Poland, 24–26 May 2012. http://accnet.web.cern.ch/accnet/Literature/2012/RFTECH_Paper_Samer_Habib.pdf
  15. 15.
    F. Löhl, V. Arsov, M. Felber et al., Electron bunch timing with femtosecond precision in a superconducting free-electron laser. Phys. Rev. Lett. (2010).  https://doi.org/10.1103/physrevlett.104.144801 CrossRefGoogle Scholar
  16. 16.
    V. Arsov, M. Dehler, S. Hunziker et al., MOAL4: First results from the bunch arrival-time monitor at the SwissFEL test injector, in Proceedings of IBIC, Oxford, UK, 16–19 September 2013. http://accelconf.web.cern.ch/AccelConf/ibic2013/papers/moal4.pdf
  17. 17.
    L. Pavlovic, A. O. Borga, M. Ferianis et al., TUPSM086: Bunch arrival monitor at fermi@ elettra, in Proceedings of BIW, Santa Fe, US, 2–6 May 2010. http://accelconf.web.cern.ch/AccelConf/BIW2010/papers/tupsm086.pdf
  18. 18.
    J. G. Wang, B. Liu. THPML065: Preliminary results of the bunch arrival-time monitor at SXFEL, in Proceedings of IPAC, Vancouver, Canada, April 29 to May 4, 2018.  https://doi.org/10.18429/jacow-ipac2018-thpml065
  19. 19.
    H. Schlarb. TOAD001: Techniques for Pump-Probe Synchronisation of Fsec Radiation Pulses, in Proceedings of 2005 Particle Accelerator Conference, Knoxville, Tennessee, USA, 16–20 MAY 2005. https://accelconf.web.cern.ch/accelconf/p05/PAPERS/TOAD001.PDF
  20. 20.
    P. Craievich, S.D. Mitri, M. Milloch et al., Modeling and experimental study to identify arrival-time jitter sources in the presence of a magnetic chicane. Phys. Rev. ST Accel. Beams 16, 090401 (2013).  https://doi.org/10.1103/physrevstab.16.090401 CrossRefGoogle Scholar
  21. 21.
    J.G. Wang, X.Q. Liu, L. Feng et al., Analysis of electro-optical intensity modulator for bunch arrival-time monitor at SXFEL. Nucl. Sci. Tech. 30, 3 (2019).  https://doi.org/10.1007/s41365-018-0524-8 CrossRefGoogle Scholar
  22. 22.
  23. 23.
    M. K. Bock. Measuring the electron bunch timing with fs resolution at FLASH. Ph.D. Thesis, University Hamburg, Hamburg, Germany (2013)Google Scholar
  24. 24.
    Xilinx, KC705 Evaluation Board for the Kintex-7 FPGA (2018). https://www.xilinx.com/support/documentation/boards_and_kits/kc705/ug810_KC705_Eval_Bd.pdf
  25. 25.
  26. 26.
    Xilinx, 7 Series FPGAs SelectIO Resources User Guide (2018) https://www.Xilinx.com/support/documentation/user_guides/ug471_7Series_SelectIO.pdf
  27. 27.
  28. 28.

Copyright information

© China Science Publishing & Media Ltd. (Science Press), Shanghai Institute of Applied Physics, the Chinese Academy of Sciences, Chinese Nuclear Society and Springer Nature Singapore Pte Ltd. 2019

Authors and Affiliations

  1. 1.Shanghai Institute of Applied PhysicsChinese Academy of ScienceShanghaiChina
  2. 2.University of the Chinese Academy of ScienceBeijingChina

Personalised recommendations