Advertisement

Experimental analysis of vibration isolation using hybrid magnet and magnetorheological fluid damper

  • Easu Dakshnamoorthy
  • Siddharthan Arjunan
  • Amrutha Radhakrishnan
Technical Paper
  • 87 Downloads

Abstract

This work analyzes the effect of magnetic field strengths of actuators on the performance of vibration isolation of quarter car model. Hybrid magnet and magnetorheological fluid damper with the nano- and micron-sized iron oxide particles are employed as actuators in parallel with the conventional elements of the car model. Experimental work has been carried out on a laboratory scale model of a two degree of freedom quarter car with the help of electrodynamic shaker, accelerometers, data acquisition card and LabVIEW software. The performance is evaluated based on suspension deflection, tire deflection and transmissibility ratio. The improvement in the performance of the combined effect of actuators is better than the conventional and individual elements.

Keywords

Hybrid magnet Magnetorheological fluid damper Suspension deflection Tire deflection Transmissibility ratio 

References

  1. 1.
    Rajamani R (2006) Vehicle dynamics and control. Springer, BerlinzbMATHGoogle Scholar
  2. 2.
    Suciu CV, Tobiishi T, Mouri R (2012) Modeling and simulation of a vehicle suspension with variable damping versus the excitation frequency. J Telecommun Inf Technol 1:83–89Google Scholar
  3. 3.
    Prabu K, Jancirani J (2012) Performance of electromagnetic based suspension system for automobiles. Int J Veh Struct Syst (IJVSS) 4(2):43–47Google Scholar
  4. 4.
    Kumar MS, Vijayarangan S (2007) Analytical and experimental studies on active suspension system of light passenger vehicle to improve ride comfort. Mechanika 65:34–40Google Scholar
  5. 5.
    Thite A (2012) Development of a refined quarter car model for the analysis of discomfort due to vibration. Adv Acoust Vib.  https://doi.org/10.1155/2012/863061 Google Scholar
  6. 6.
    Mache AR, Joshi SG (2007) Theoretical and experimental dynamic response analysis of a road vehicle suspension system using an electromagnetic damper, SAE International, (SP-2146) 2007-01-4271Google Scholar
  7. 7.
    Nagai M, Tananka S (1992) Study on the dynamic stability of repulsive magnetic levitation systems. JSME Int J 33(1):102–108Google Scholar
  8. 8.
    Nagaya K, Hata H, Sakamoto N, Nojiri A, Murakami I (2008) Vibration isolation system using spring actuator with iron particle layers stacked with permanent magnet and electromagnet under disturbance cancellation control. J Optoelectron Adv Mater 10(5):1222–1227Google Scholar
  9. 9.
    Van der Sande TPJ, Gysen BLJ, Besselink IJM, Paulides JJH, Lomonova EA, Nijmeijer H (2013) Robust control of an electromagnetic active suspension system: simulations and measurements. Mechatronics 23:204–212CrossRefGoogle Scholar
  10. 10.
    Lei S, Palazzolo A (2008) Control of flexible rotor systems with acive magnetic bearings. J Sound Vib 314:19–38CrossRefGoogle Scholar
  11. 11.
    Hreinsson E (2011) Durability of a magnetorheological fluid in a prosthetic knee joint, M.Sc. Thesis, University of IcelandGoogle Scholar
  12. 12.
    Janocha H (2001) Application potential of magnetic field driven new actuators. Sens Actuators A91:126–132CrossRefGoogle Scholar
  13. 13.
    Jagadish Kori G, Jangid RS (2009) Semi-active MR dampers for seismic control of structures. Bull N Z Soc Earthq Eng 42(3):157–166Google Scholar
  14. 14.
    Switonski E, Mezyk A, Duda S, Kciuk S (2007) Prototype magnetorheological fluid damper for active vibration control system. J Achiev Mater Manuf Eng 21(1):71–74Google Scholar
  15. 15.
    Symans MD, Constantinou MC (1999) Semi-active control systems for seismic protection of structures: a state-of-the-art review. Eng Struct 21:469–487CrossRefGoogle Scholar
  16. 16.
    Rosenfeld N, Wereley NM, Radakrishnan R, Sudarshan TS (2002) Behavior of magnetorheological fluids utilizing nanopowder iron. Int J Mod Phys B.  https://doi.org/10.1142/S0217979202012414 Google Scholar
  17. 17.
    Lee H-J, Moonb S-J, Jung H-J (2008) Integrated design method of MR damper and electromagnetic induction system for structural control. Proc SPIE 6932:69320S-1CrossRefGoogle Scholar
  18. 18.
    Kciuk S, Mężyk A, Klein W (2011) The numerical and experimental studies of the prototype MR damper. In: Active noise and vibration control methods, Krakow-Wojanow, Poland, June 06–08Google Scholar
  19. 19.
    Pranoto T, Nagaya K, Ebara Y, Long QQ (2007) Vibration suppression device using permanent-electromagnet. J Mater Process Technol 181:235–240CrossRefGoogle Scholar
  20. 20.
    Mallik AK (1990) Principles of vibration control. Affiliated East-West Press (P) Ltd, New DelhiGoogle Scholar

Copyright information

© The Brazilian Society of Mechanical Sciences and Engineering 2018

Authors and Affiliations

  1. 1.Department of Mechanical EngineeringKCG College of TechnologyChennaiIndia
  2. 2.Department of Production TechnologyMIT Campus, Anna UniversityChennaiIndia
  3. 3.Department of Science and HumanitiesKCG College of TechnologyChennaiIndia