Advertisement

Toxicology and Environmental Health Sciences

, Volume 11, Issue 4, pp 278–282 | Cite as

Assessment of the Cellphone Radiations Effects on Anti-oxidative and Renal Parameters in Rat

  • Elham Eslami
  • Soheil FatahianEmail author
  • Kahin Shahanipour
Original article
  • 4 Downloads

Abstract

Objective: In the present study an attempt is to assess the cellphones waves effects on the stress oxida-tive activities as well as renal parameters in rat.

Methods:30 mature male Wister rats were divided into 3 groups of 10. Group 1 (control) was kept in normal laboratory conditions. Groups 2 and 3 were exposed with two and four cellphones in opposite sides of the cage, respectively. Blood samples were collected directly from the rat’s heart 15 and 30 days post exposure and the activity of anti-oxidative factors including Glutathione Peroxidase, Superoxide Dis-mutase, Catalase, Glutathione Peroxidase, Paraoxo-nase and Malondialdehyde as well as renal parameters (Urea, Uric acid and Creatinine) were measured.

Results: Activity of catalase, superoxide dismutase and paraoxonase enzymes in all treated groups, 15 and 30 days post cellphone exposure were significantly increased in comparison with control. The activity of glutathione peroxidase enzyme in all treated groups, 15 and 30 days post cellphone exposure was decreased in comparison with control. Malondialde-hyde and creatinine activity did not show any significant changes. Uric acid and urea were significantly increased in the group just exposed with four cellphones, 30 days post exposure.

Conclusion: According to the results, many changes were seen in biochemical parameters due to the cellphone exposure during a month. Therefore it can be concluded that radio frequency devices could be destructive and have many negative effects on the tissues and enzyme function.

Keywords

Cell phone Antioxidant Oxidative Rat Biochemical parameters 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Notes

Acknowledgments

All of the results presented in this paper are based on the dataset of a MSc. thesis, which is done at the Islamic Azad University, Falavarjan branch. There is no financial support and all of expenses are paid by the author. The authors intend to thank from the staff of the Islamic Azad University, Falavarjan branch for their cooperation.

References

  1. 1.
    Hardell, L. & Sage, C. Biological Effects from Electromagnetic Field Exposure and Public Exposure Standards. Biomed. Pharmacother. 62, 104–109 (2008).CrossRefGoogle Scholar
  2. 2.
    Ryu, J.-C. & Ahn, J.-Y. Special Issue: Abstracts of the 10th International Conference on Environmental Health Science. Toxicol. Environ. Health Sci. 9, 1–81 (2017).Google Scholar
  3. 3.
    Parivar, K., Nabiuni, M., Golestanian, N. & Amini, E. Effect of Low Frequency Electromagnetic Fields on the Spermatogenesis and Blood Serum Protein of Balb/c Mice. J. Cell & Tissue. 2, 47–56 (2011).Google Scholar
  4. 4.
    Neužilová, B., Ondrák, L., Čuba, V. & Múčka, V. Influence of the Dose Rate of Gamma Irradiation and Some Other Conditions on the Radiation Protection of Microbial Cells by Scavenging of OH Radicals. J. Radioanal. Nucl. Chem.318, 2449–2453(2018).CrossRefGoogle Scholar
  5. 5.
    Múčka, V., Červenák, J., Čuba, V. & Bláha, P. Determination of the Survival of Yeast and Bacteria Under the Influence of Gamma or UV Radiation in the Presence of Some Scavengers of OH Radicals. J. Radioanal. Nucl. Chem.304, 237–244(2015).CrossRefGoogle Scholar
  6. 6.
    Khadrawy, K. H., Ahmed, N., Aboulezz, H. & Radwan, N. M. Effect of Electromagnetic Radiation From Mobile Phone on the Levels of Cortical Amino Acid Neu-rotransmitters in Adult and Young Rats. Romanian J. Biophys. 19, 295–305 (2009).Google Scholar
  7. 7.
    Lee, J. S., Ahn, S. S., Jung, K. C., Kirn, Y. W. & Lee, S. K. Effects of 60Hz Electromagnetic Field Exposure on Testicular Germ Cell Apoptosis in Mice. Asian J. Androl. 6, 29–34 (2004).PubMedGoogle Scholar
  8. 8.
    Gharamaleki, H., Soleimani, R. J., Roshangar, L., Vatanhah, A. M. & Valipour. A. Effect of Extremely Low-frequency Electromagnetic Field Exposure on Bio-markers of Oxidative Stress in Pregnant Rats. J. Laboratory & Diagnosis6, 31–35 (2014).Google Scholar
  9. 9.
    Ireland, D. & Abbosh, A. Modeling Human at Microwave Frequencies Using Optimized Debye Models and FDTD Method. IEEE. Transactions on Antennas and Propagation61, 2352–2355 (2013).CrossRefGoogle Scholar
  10. 10.
    Lazebnik, M., Okoniewski, M., Booske, J. H. & Hagness, S. C. Highly Accurate Debye Models for Normal and Malignant Breast Tissue Dielectric Properties at Microwave Frequencies, IEEE. Microwave and Wireless Components Lett. 17, 822–824 (2007).CrossRefGoogle Scholar
  11. 11.
    Frey, A. H. Electromagnetic Field Interaction with Biological Systems. FASEB. J. 7, 272–281 (1993).CrossRefGoogle Scholar
  12. 12.
    Kesari, K. K., Kumar, S. & Behari, J. 900-MHz Microwave Radiation Promotes Oxidation in Rat Brain. Ele-ctromag. Biology Med. 30, 19–34 (2011).Google Scholar
  13. 13.
    Canseven, A. G., Coskun, S. & Seyhan, N. Effects of Various Extremely low Frequency Magnetic Fields on the Free Radical Processes, Natural Antioxidant System and Respiratory Burst System Activities in the Heart and Liver Tissues. Indian J. Biochem & Biophys. 45, 326–331 (2008).Google Scholar
  14. 14.
    Ozgur, E., Öytürk, G. G. & Seyhan, N. Regenerative Effects of (-)-epigallocatechin-gallate Against Hepatic Oxidative Stress Resulted by Mobile Phone Exposure. 11th Mediterranean Con. Med. Biomed. Eng. Comput. 16, 214–217 (2007).Google Scholar
  15. 15.
    Awad, S. M. & Hassan, N. S. Health Risks of Electromagnetic Radiation from Mobile Phone on Brain of Rat. J. Appl. Sci. Res. 4, 1994–2000 (2008).Google Scholar
  16. 16.
    Asgari, M., Ahmadi, R. & Gohari, A. The Effects of Mobile Phone Radiation on Serum Levels of Creati-nine in Male Rats. Int. Con. Earth, Environ. Life Sci. 23–24, Dubai (2014).Google Scholar
  17. 17.
    Lotfi, S. A. Effect of Electromagnetic Radiation Emitted from a Mobile Phone Station on Biochemical and Histological Structure of Some Rat Organs. Isotope & Radia. Res. 43, 95–103 (2011).Google Scholar
  18. 18.
    Hangzhou Eastbiopharm Co., LTD. http://www.east-biopharm.com/english/Products_list_8 (2009).
  19. 19.
    Taligene Pars Co., ISTT. http://taligene.com/?lang=en (2011).

Copyright information

© The Korean Society of Environmental Risk Assessment and Health Science and Springer 2019

Authors and Affiliations

  • Elham Eslami
    • 1
  • Soheil Fatahian
    • 1
    Email author
  • Kahin Shahanipour
    • 1
  1. 1.Falavarjan branchIslamic Azad UniversityIsfahanIran

Personalised recommendations