Abstract

Ambient mass spectrometry is a powerful approach for rapid, high-throughput, and direct sample analysis. Due to the open-air desorption and ionization processes, random fluctuations of ambient conditions can lead to large variances in mass-spectral signals over time. The mass-spectral data also can be further complicated due to multiple analytes present in the sample, background-ion signals stemming from the desorption/ionization source itself, and other laboratory-specific conditions (e.g., ambient laboratory air, nearby hardware). Thus, background removal and analyte-ion recognition can be quite difficult, particularly in non-targeted analyses. Here, we demonstrate the use of a cross-correlation-based approach to exploit chemical information encoded in the time domain to group/categorize mass-spectral peaks from a single analysis dataset. Ions that originate from ambient (or other) background species were readily flagged and removed from spectra; the result was a decrease in mass-spectral complexity by over 70% due to the removal of these background ions. Meanwhile, analyte ions were differentiated and categorized based on their time-domain profiles. With sufficient mass resolving-power and mass-spectral acquisition rate, isolated mass spectra containing ions from the same species in a sample could be extracted, leading to a reduction in mass-spectral complexity by more than 98% in some cases. The cross-correlation approach was tested with different ionization sources as well as reproducible and irreproducible sample introduction. Software built in-house enabled fully automated data processing, which can be performed within a few seconds. Ultimately, this approach provides an additional dimension of analyte separation in ambient mass-spectrometric analyses with information that is already recorded throughout the analysis.

Keywords

Ambient desorption/ionization Data processing DART FAPA MS/MS Cross-correlation 

Notes

Acknowledgements

We sincerely appreciate Dr. Leah Shriver and coworkers at the University of Akron for the kind donation of the γ-aminobutyric acid (GABA) standard used in this work.

Supplementary material

13361_2019_2246_MOESM1_ESM.docx (907 kb)
ESM 1 (DOCX 906 kb)

References

  1. 1.
    Cooks, R.G., Ouyang, Z., Takats, Z., Wiseman, J.M.: Ambient mass spectrometry. Science. 311(5767), 1566–1570 (2006)Google Scholar
  2. 2.
    Monge, M.E., Harris, G.A., Dwivedi, P., Fernández, F.M.: Mass spectrometry: recent advances in direct open air surface sampling/ionization. Chem. Rev. 113(4), 2269–2308 (2013)Google Scholar
  3. 3.
    Nounou, P.: Mass spectrometry of aromatic compounds. 3. Ionization and dissociation of PHENANTHRENE and METHYLPHENANTHRENE molecules by electron impact. J. Chim. Phys. 65(4), 700 (1968)Google Scholar
  4. 4.
    Munson, M.S., Field, F.-H.: Chemical ionization mass spectrometry. I. General introduction. J. Am. Chem. Soc. 88(12), 2621–2630 (1966)Google Scholar
  5. 5.
    Chen, T.-C., Ouyang, Z.: Synchronized discharge ionization for analysis of volatile organic compounds using a hand-held ion trap mass spectrometer. Anal. Chem. 85(3), 1767–1772 (2013)Google Scholar
  6. 6.
    Takats, Z., Wiseman, J.M., Gologan, B., Cooks, R.G.: Mass spectrometry sampling under ambient conditions with desorption electrospray ionization. Science. 306(5695), 471–473 (2004)Google Scholar
  7. 7.
    Venter, A., Nefliu, M., Cooks, R.G.: Ambient desorption ionization mass spectrometry. TrAC Trends Anal. Chem. 27(4), 284–290 (2008)Google Scholar
  8. 8.
    Cody, R.B., Laramée, J.A., Durst, H.D.: Versatile new ion source for the analysis of materials in open air under ambient conditions. Anal. Chem. 77(8), 2297–2302 (2005)Google Scholar
  9. 9.
    Cody, R.B., Laramée, J.A., Nilles, J.M., Durst, H.D.: Direct analysis in real time (DARTtm) mass spectrometry. JEOL news. 40(1), 8–12 (2005)Google Scholar
  10. 10.
    Andrade, F.J., Shelley, J.T., Wetzel, W.C., Webb, M.R., Gamez, G., Ray, S.J., Hieftje, G.M.: Atmospheric pressure chemical ionization source. 1. Ionization of compounds in the gas phase. Anal. Chem. 80(8), 2646–2653 (2008)Google Scholar
  11. 11.
    Shelley, J.T., Wiley, J.S., Hieftje, G.M.: Ultrasensitive ambient mass spectrometric analysis with a pin-to-capillary flowing atmospheric-pressure afterglow source. Anal. Chem. 83(14), 5741–5748 (2011)Google Scholar
  12. 12.
    Badal, S.P., Michalak, S.D., Chan, G.C.-Y., You, Y., Shelley, J.T.: Tunable ionization modes of a flowing atmospheric-pressure afterglow (FAPA) ambient ionization source. Anal. Chem. 88(7), 3494–3503 (2016)Google Scholar
  13. 13.
    Schwartz, A.J., Shelley, J.T., Walton, C.L., Williams, K.L., Hieftje, G.M.: Atmospheric-pressure ionization and fragmentation of peptides by solution-cathode glow discharge. Chem. Sci. 7(10), 6440–6449 (2016)Google Scholar
  14. 14.
    Nilles, J.M., Connell, T.R., Stokes, S.T., Dupont Durst, H.: Explosives detection using direct analysis in real time (DART) mass spectrometry. Propellants Explos. Pyrotech. 35(5), 446–451 (2010)Google Scholar
  15. 15.
    Vaclavik, L., Rosmus, J., Popping, B., Hajslova, J.: Rapid determination of melamine and cyanuric acid in milk powder using direct analysis in real time-time-of-flight mass spectrometry. J. Chromatogr. A. 1217(25), 4204–4211 (2010)Google Scholar
  16. 16.
    Crawford, E., Musselman, B.: Evaluating a direct swabbing method for screening pesticides on fruit and vegetable surfaces using direct analysis in real time (DART) coupled to an Exactive benchtop orbitrap mass spectrometer. Anal. Bioanal. Chem. 403(10), 2807–2812 (2012)Google Scholar
  17. 17.
    Schilling, G.D., Shelley, J.T., Barnes, J.H., Sperline, R.P., Denton, M.B., Barinaga, C.J., Koppenaal, D.W., Hieftje, G.M.: Detection of positive and negative ions from a flowing atmospheric pressure afterglow using a Mattauch-Herzog mass spectrograph equipped with a faraday-strip array detector. J. Am. Soc. Mass Spectrom. 21(1), 97–103 (2010)Google Scholar
  18. 18.
    Cajka, T., Riddellova, K., Tomaniova, M., Hajslova, J.: Ambient mass spectrometry employing a DART ion source for metabolomic fingerprinting/profiling: a powerful tool for beer origin recognition. Metabolomics. 7(4), 500–508 (2011)Google Scholar
  19. 19.
    Pan, Z., Li, Y., Deng, X., Xiao, S.: Non-targeted metabolomic analysis of orange (Citrus sinensis [L.] Osbeck) wild type and bud mutant fruits by direct analysis in real-time and HPLC-electrospray mass spectrometry. Metabolomics. 10(3), 508–523 (2014)Google Scholar
  20. 20.
    Windig, W., Phalp, J.M., Payne, A.W.: A noise and background reduction method for component detection in liquid chromatography/mass spectrometry. Anal. Chem. 68(20), 3602–3606 (1996)Google Scholar
  21. 21.
    Zhu, P.J., Ding, W., Tong, W., Ghosal, A., Alton, K., Chowdhury, S.: A retention-time-shift-tolerant background subtraction and noise reduction algorithm (BgS-NoRA) for extraction of drug metabolites in liquid chromatography/mass spectrometry data from biological matrices. Rapid Commun. Mass Spectrom. 23(11), 1563–1572 (2009)Google Scholar
  22. 22.
    Shelley, J.T., Wiley, J.S., Chan, G.C., Schilling, G.D., Ray, S.J., Hieftje, G.M.: Characterization of direct-current atmospheric-pressure discharges useful for ambient desorption/ionization mass spectrometry. J. Am. Soc. Mass Spectrom. 20(5), 837–844 (2009)Google Scholar
  23. 23.
    Zhang, Y., Ma, X., Zhang, S., Yang, C., Ouyang, Z., Zhang, X.: Direct detection of explosives on solid surfaces by low temperature plasma desorption mass spectrometry. Analyst. 134(1), 176–181 (2009)Google Scholar
  24. 24.
    Chipuk, J.E., Brodbelt, J.S.: Transmission mode desorption electrospray ionization. J. Am. Soc. Mass Spectrom. 19(11), 1612–1620 (2008)Google Scholar
  25. 25.
    Evans-Nguyen, K.M., Quinto, A., Hargraves, T., Brown, H., Speer, J., Glatter, D.: Transmission mode desorption electrospray ionization (TM-DESI) for simultaneous analysis of potential inorganic and organic components of radiological dispersion devices (RDDs). Anal. Chem. 85(24), 11826–11834 (2013)Google Scholar
  26. 26.
    Jones, C.M., Fernández, F.M.: Transmission mode direct analysis in real time mass spectrometry for fast untargeted metabolic fingerprinting. Rapid Commun. Mass Spectrom. 27(12), 1311–1318 (2013)Google Scholar
  27. 27.
    Chipuk, J.E., Gelb, M.H., Brodbelt, J.S.: Rapid and selective screening for sulfhydryl analytes in plasma and urine using surface-enhanced transmission mode desorption electrospray ionization mass spectrometry. Anal. Chem. 82(10), 4130–4139 (2010)Google Scholar
  28. 28.
    Schilling, G.D., Shelley, J.T., Broekaert, J.A.C., Sperline, R.P., Denton, M.B., Barinaga, C.J., Koppenaal, D.W., Hieftje, G.M.: Use of an ambient ionization flowing atmospheric-pressure afterglow source for elemental analysis through hydride generation. J. Anal. At. Spectrom. 24(1), 34–40 (2009)Google Scholar
  29. 29.
    Allen, J., Berkley, D., Blauert, J.: Multimicrophone signal-processing technique to remove room reverberation from speech signals. J Acoust Soc Am. 62(4), 912–915 (1977)Google Scholar
  30. 30.
    Owens, K.G.: Application of correlation analysis techniques to mass spectral data. Appl. Spectrosc. Rev. 27(1), 1–49 (1992)Google Scholar
  31. 31.
    Meehan, T. K.: Multipath noise reduction for spread spectrum signals. Google Patents. Retrieved from https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/19950007215.pdf. (1994)
  32. 32.
    Powell, L.A., Hieftje, G.: Computer identification of infrared spectra by correlation-based file searching. Anal. Chim. Acta. 100, 313–327 (1978)Google Scholar
  33. 33.
    Stein, S.E., Scott, D.R.: Optimization and testing of mass spectral library search algorithms for compound identification. J. Am. Soc. Mass Spectrom. 5(9), 859–866 (1994)Google Scholar
  34. 34.
    Mueller, C., Weinmann, W., Dresen, S., Schreiber, A., Gergov, M.: Development of a multi-target screening analysis for 301 drugs using a QTrap liquid chromatography/tandem mass spectrometry system and automated library searching. Rapid Commun. Mass Spectrom. 19(10), 1332–1338 (2005)Google Scholar
  35. 35.
    Eng, J.K., McCormack, A.L., Yates, J.R.: An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein database. J. Am. Soc. Mass Spectrom. 5(11), 976–989 (1994)Google Scholar
  36. 36.
    Yates III, J.R., Eng, J.K., McCormack, A.L., Schieltz, D.: Method to correlate tandem mass spectra of modified peptides to amino acid sequences in the protein database. Anal. Chem. 67(8), 1426–1436 (1995)Google Scholar
  37. 37.
    Tabb, D. L.; Eng, J. K.; Yates III, J. R.: Protein identification by SEQUEST. In Proteome Research: Mass Spectrometry, pp. 125–142. Springer (2001)Google Scholar
  38. 38.
    Eng, J.K., Fischer, B., Grossmann, J., MacCoss, M.J.: A fast SEQUEST cross correlation algorithm. J. Proteome Res. 7(10), 4598–4602 (2008)Google Scholar
  39. 39.
    Chernetsova, E.S., Crawford, E.A., Shikov, A.N., Pozharitskaya, O.N., Makarov, V.G., Morlock, G.E.: ID-CUBE direct analysis in real time high-resolution mass spectrometry and its capabilities in the identification of phenolic components from the green leaves of Bergenia crassifolia L. Rapid Commun. Mass Spectrom. 26(11), 1329–1337 (2012)Google Scholar
  40. 40.
    Yu, S., Crawford, E., Tice, J., Musselman, B., Wu, J.-T.: Bioanalysis without sample cleanup or chromatography: the evaluation and initial implementation of direct analysis in real time ionization mass spectrometry for the quantification of drugs in biological matrixes. Anal. Chem. 81(1), 193–202 (2008)Google Scholar
  41. 41.
    Gross, J.H.: Direct analysis in real time—a critical review on DART-MS. Anal. Bioanal. Chem. 406(1), 63–80 (2014)Google Scholar
  42. 42.
    Husen, P., Tarasov, K., Katafiasz, M., Sokol, E., Vogt, J., Baumgart, J., Nitsch, R., Ekroos, K., Ejsing, C.S.: Analysis of lipid experiments (ALEX): a software framework for analysis of high-resolution shotgun lipidomics data. PLoS One. 8(11), e79736 (2013)Google Scholar
  43. 43.
    Tyanova, S., Mann, M., Cox, J.: MaxQuant for in-depth analysis of large SILAC datasets.In: Warscheid B. (ed) Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC). Methods in Molecular Biology (Methods and Protocols), vol 1188. Humana Press, New York, NY 351–364 (2014)Google Scholar
  44. 44.
    Guo, X., Bruins, A.P., Covey, T.R.: Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry. Rapid Commun. Mass Spec.: An International Journal Devoted to the Rapid Dissemination of Up-to-the-Minute Research in Mass Spectrometry. 20(20), 3145–3150 (2006)Google Scholar
  45. 45.
    Kaiser, J., Reed, W.: Data smoothing using low-pass digital filters. Rev. Sci. Instrum. 48(11), 1447–1457 (1977)Google Scholar
  46. 46.
    Smith CA, O'Maille G, Want EJ, Qin C, Trauger SA, Brandon TR, Custodio DE, Abagyan R, Siuzdak G. METLIN: a metabolite mass spectral database. Ther Drug Monit [Internet]. 27, 747–751 (2005)Google Scholar
  47. 47.
    McEwen, C.N., McKay, R.G., Larsen, B.S.: Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments. Anal. Chem. 77(23), 7826–7831 (2005)Google Scholar

Copyright information

© American Society for Mass Spectrometry 2019

Authors and Affiliations

  1. 1.Department of Chemistry and BiochemistryKent State UniversityKentUSA
  2. 2.Department of Chemistry and Chemical BiologyRensselaer Polytechnic InstituteTroyUSA