Cell sorting requires a stable flowing speed, especially for a fast flow cytometry like the optical time-stretch imaging. The flowing speed fluctuation of Euglena cells and Nile red particles is tested and evaluated by a home-built flowing speed testing system. Higher flowing speeds have better stability. Flowing microchannels with controlling steps also improve the speed stability. The time fluctuation is ~ 1 ms under a flowing speed of ~ 1.4 m/s. Cell sorting can be realized by either using an ultra-short delay time between the sorting point and imaging point, which is suitable for relative lower cells counting speed (~ 5000 cells/s), or developing effective fluctuation controlling methods for higher counting speed, like using step glass microchannels.

Keywords

Cytometry Cell sorting Flowing speed test Flowing cells stability 

Notes

Acknowledgements

This study was supported by National Natural Science Foundation of China (NSFC) under Grant 61605140.

References

  1. 1.
    A. Orfao, A. Ruiz-Arguelles, General concepts about cell sorting techniques. Clin. Biochem. 29, 5–7 (1996)CrossRefGoogle Scholar
  2. 2.
    L.A. Herzenberg, R.G. Sweet, L.A. Herzenberg, Fluorescence activated cell sorting. Science 234, 108–117 (1974)Google Scholar
  3. 3.
    T. Lindmo, D.C. Peters, R.G. Sweet, Flow sorters for biological cells, in Flow Cytometry and Sorting, 2nd edn., ed. by M.R. Melamed, T. Lindmo, M.L. Mendelsohn (Wiley, New York, 1990), pp. 145–169Google Scholar
  4. 4.
    H.M. Shapiro, Practical Flow Cytometry (Wiley, New York, 2003)CrossRefGoogle Scholar
  5. 5.
    M.H. Julius, T. Masuda, L.A. Herzenberg, Demonstration that antigen-binding cells are precursors of antibody-producing cells after purification with a fluorescence-activated cell sorter. Proc. Natl. Acad. Sci. U. S. A. 69(7), 1934–1938 (1972)ADSCrossRefGoogle Scholar
  6. 6.
    H.R. Hulett, W.A. Bonner, J. Barret, L.A. Herzenberg, Cell sorting: automated separation of mammalian cells as a function of intracellular fluorescence. Science 166, 747–749 (1969)ADSCrossRefGoogle Scholar
  7. 7.
    K. Goda, K.K. Tsia, B. Jalali, Serial time-encoded amplified imaging for real-time observation of fast dynamic phenomena. Nature 458, 1145–1149 (2009)ADSCrossRefGoogle Scholar
  8. 8.
    K. Goda, A. Ayazi, D.R. Gossett, J. Sadasivam, C.K. Lonappan, E. Sollier, A.M. Fard, S.C. Hur, J. Adam, C. Murray, C. Wang, N. Brackbill, D. Di Carlo, B. Jalali, High-throughput single-microparticle imaging flow analyzer. Proc. Natl. Acad. Sci. U. S. A. 109, 11630 (2012)ADSCrossRefGoogle Scholar
  9. 9.
    T.T. Wong, A.K. Lau, K.K. Ho, M.Y. Tang, J.D. Robles, X. Wei, A.C. Chan, A.H. Tang, E.Y. Lam, K.K. Wong, G.C. Chan, H.C. Shum, K.K. Tsia, Asymmetric-detection time-stretch optical microscopy (ATOM) for ultrafast high-contrast cellular imaging in flow. Sci. Rep. 4, 3656 (2014)ADSCrossRefGoogle Scholar
  10. 10.
    M. Li, H. Munoz, A. Schmidt, B. Guo, C. Lei, K. Goda, D.D. Carlo, Inertial focusing of ellipsoid Euglena gracilis cells in a stepped microchannel. Lab Chip 16, 4458 (2016)CrossRefGoogle Scholar
  11. 11.
    B. Guo, C. Lei, T. Ito, Y. Jiang, Y. Ozeki, K. Goda, High-throughput accurate single-cell screening of Euglena gracilis with fluorescence-assisted optofluidic time-stretch microscopy. PLoS ONE 11, e0166214 (2016)CrossRefGoogle Scholar

Copyright information

© The Optical Society of India 2019

Authors and Affiliations

  1. 1.Laser Micro/Nano Fabrication Laboratory, School of Mechanical EngineeringBeijing Institute of TechnologyBeijingChina

Personalised recommendations