Advertisement

Analysis of performance and economical efficiency of two-stage compression heat pump system with inter-stage injection in cold regions of northern China

  • Xu Jin
  • Zhe Wu
  • Kuo Zhang
  • Zhongyan LiuEmail author
  • Wenpeng Hong
  • Xiaoyi Li
Research Article
  • 6 Downloads

Abstract

The low temperature adaptability of air source heat pump in the field of building heating in cold regions has always been a hot topic. At present, the combination of inter-stage injection technology and two-stage compression can effectively solve the problem of low temperature adaptability. Therefore, in the present paper, the two-stage compression heat pump system with inter-stage injection was taken as the research project. Based on the simulation model of the two-stage compression heat pump system, the process of inter-stage injection coupling between the low-stage compressor and the high-stage compressor was analyzed. Based on the experimental results, the effects of inter-stage injection process on the inter-stage pressure, inter-stage temperature and thermal performance parameters of the two-stage compression system were analyzed. The results show that as the mass of inter-stage injection increases, the inter-stage pressure will increase significantly and then increase slowly; and the inter-stage temperature will increase slowly and then decrease significantly; both the heat output and the COP will increase first and then slightly decrease. In addition, the heat output will increase by about 8%–15%, and the COP will increase by about 5%–12%. Finally, the two regions including Beijing and Dalian in China were selected, and the economical efficiency of the system in applications was analyzed in combination with the experimental results of variable working conditions of the system.

Keywords

two-stage compression heat pump variable capacity coupling characteristics inter-stage injection economic performance analysis 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Notes

Acknowledgements

This work was supported by a grant from the Science and Technology Project of Educational Commission of Jilin Province, China (No. JJKH20180097KJ), the Development and Innovation Project of Science and Technology Commission of Jilin city, China (No. 201750214), the Key technology research Project of Science and Technology Commission of Jilin Province, China (No. 20180201006SF), and the National Key R&D Program of China (2018YFB0905104), and the Major Science and Technology Bidding Special Project of Jilin Province, China (No. 20170203006SF).

References

  1. Beeton WL, Pham HM (2003). Vapor-injection scroll compressors. ASHRAE Journal, 45(4): 22–27.Google Scholar
  2. Chua KJ, Chou SK, Yang WM (2010). Advances in heat pump systems: A review. Applied Energy, 87: 3611–3624.CrossRefGoogle Scholar
  3. Hepbasli A, Kalinci Y (2009). A review of heat pump water heating systems. Renewable and Sustainable Energy Reviews, 13: 1211–1229.CrossRefGoogle Scholar
  4. Jiang S, Wei D, Jiang H (2012). Design of low ambient temperature air source heat pump and its application in cold regions of China. Refrigeration and Air Conditioning, 12(5): 39–44. (in Chinese)Google Scholar
  5. Le H, Li Hao, Jiang Y (2017). Using air source heat pump air heater (ASHP-AH) for rural space heating and power peak load shifting. Energy Procedia, 122: 631–636.CrossRefGoogle Scholar
  6. Li Q (2003). Dynamic characteristics and energy consumption analysis of residential air source heat pump central air conditioning unit. Master Thesis, Tianjin University, China. (in Chinese)Google Scholar
  7. Li Y, Yu J (2016). Theoretical analysis on optimal configurations of heat exchanger and compressor in a two-stage compression air source heat pump system. Applied Thermal Engineering, 96: 682–689.CrossRefGoogle Scholar
  8. Long W (1992). Using BIN parameters for building energy analysis. Journal of HV&AC, 22(2): 6–11. (in Chinese)Google Scholar
  9. Navarro E, Redón A, Gonzálvez-Macia J, Martinez-Galvan IO, Corberán JM (2013). Characterization of a vapor injection scroll compressor as a function of low, intermediate and high pressures and temperature conditions. International Journal of Refrigeration, 36: 1821–1829.CrossRefGoogle Scholar
  10. Oquendo FMT, Peris EN, Macia JG, Corberán JM (2016). Performance of a scroll compressor with vapor-injection and two-stage reciprocating compressor operating under extreme conditions. International Journal of Refrigeration, 63: 144–156.CrossRefGoogle Scholar
  11. Qiao H, Aute V, Radermacher R (2015a). Transient modeling of a flash tank vapor injection heat pump system—Part I: Model development. International Journal of Refrigeration, 49: 169–182.CrossRefGoogle Scholar
  12. Qiao H, Xu X, Aute V, Radermacher R (2015b). Transient modeling of a flash tank vapor injection heat pump system—Part II: Simulation results and experimental validation. International Journal of Refrigeration, 49: 183–194.CrossRefGoogle Scholar
  13. Safa AA, Fung AS, Kumar R (2015). Performance of two-stage variable capacity air source heat pump: Field performance results and TRNSYS simulation. Energy and Buildings, 94: 80–90.CrossRefGoogle Scholar
  14. Taylor JR (1997). An Introduction to Error Analysis, 2nd edn. Sausalito, CA, USA: University Science Books.Google Scholar
  15. Torrella E, Larumbe JA, Cabello R, Llopis R, Sanchez D (2011). A general methodology for energy comparison of intermediate configurations in two-stage vapour compression refrigeration systems. Energy, 36: 4119–4124.CrossRefGoogle Scholar
  16. van de Bor DM, Ferreira CAI, Kiss AA (2015). Low grade waste heat recovery using heat pumps and power cycles. Energy, 89: 864–873.CrossRefGoogle Scholar
  17. Wang X, Hwang Y, Radermacher R (2009). Two-stage heat pump system with vapor-injected scroll compressor using R410A as a refrigerant. International Journal of Refrigeration, 32: 1442–1451.CrossRefGoogle Scholar
  18. Wang W, Feng YC, Zhu JH, Li LT, Guo QC, Lu WP (2013). Performances of air source heat pump system for a kind of mal-defrost phenomenon appearing in moderate climate conditions. Applied Energy, 112: 1138–1145.CrossRefGoogle Scholar
  19. Wang B, Liu X, Shi W (2017). Performance improvement of air source heat pump using gas-injected rotary compressor through port on blade. International Journal of Refrigeration, 73: 91–98.CrossRefGoogle Scholar
  20. Wu X, Xing Z, He Z, Wang X, Chen W (2016). Performance evaluation of a capacity-regulated high temperature heat pump for waste heat recovery in dyeing industry. Applied Thermal Engineering, 93: 1193–1201.CrossRefGoogle Scholar
  21. Xu S, Ma G (2015). Working performance of R-32 two-stage compression system in domestic air-conditioner. Energy and Buildings, 93: 324–331.CrossRefGoogle Scholar
  22. Yan G, Jia Q, Bai T (2016). Experimental investigation on vapor injection heat pump with a newly designed twin rotary variable speed compressor for cold regions. International Journal of Refrigeration, 62: 232–241.CrossRefGoogle Scholar
  23. Yang W, Cao X, He Y, Yan F (2017). Theoretical study of a hightemperature heat pump system composed of a CO2 transcritical heat pump cycle and a R152a subcritical heat pump cycle. Applied Thermal Engineering, 120: 228–238.CrossRefGoogle Scholar
  24. Zhang L (2009). Improve the technical level of the industry and standardize the market order: Standard analysis of “Low Ambient Temperature Air Source Heat Pump (Cold Water) Units for Industrial or Commercial Use And Similar Purposes”. Electric Appliance, 2009(3): 24–25. (in Chinese)Google Scholar

Copyright information

© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2019

Authors and Affiliations

  • Xu Jin
    • 1
  • Zhe Wu
    • 1
  • Kuo Zhang
    • 1
  • Zhongyan Liu
    • 1
    Email author
  • Wenpeng Hong
    • 1
  • Xiaoyi Li
    • 1
  1. 1.Heat Pump Technology InstituteNortheast Electric Power UniversityJilinChina

Personalised recommendations