A new extrapolation expression for exposure evaluation inside a human-equivalent liquid phantom in the vicinity of wireless power transfer systems

  • Satoshi Shimoyama
  • Jerdvisanop ChakarothaiEmail author
  • Kanako Wake
  • Takuji Arima
  • Soichi Watanabe
  • Toru Uno
Article
  • 34 Downloads

Abstract

To ensure human safety against electromagnetic exposures from wireless power transfer (WPT) systems operating at MHz-band frequencies, a compliance test must be conducted using either numerical simulations or measurements. In practice, measurements of the specific absorption rate (SAR) inside a human-equivalent liquid phantom are required for exposure evaluation. However, accurate measurements of SAR are difficult, especially at a location close to the phantom boundary, owing to the boundary effect, caused by the field disturbance due to the SAR probe itself. Hence, it is necessary to use an extrapolation method to determine the internal electric field or SAR. In this study, we propose a new extrapolation expression based on the characteristic of electromagnetic fields inside the phantom in order to estimate internal electric field strength or SAR. The validity of the proposed expression was demonstrated both numerically and experimentally. From the results, we confirmed that the difference in the internal electric field strength inside a liquid phantom was less than 3% between our proposed extrapolation expression and the method of moments (MoM). For SAR measurements using two types of actual WPT systems, i.e., solenoid and flat-spiral types, we found that the proposed expression can be used to evaluate the spatial peak 10-g average SAR with a difference of less than 30% compared with those numerically obtained by MoM.

Keywords

Compliance test Exposure evaluation Extrapolation method Specific absorption rate Wireless power transfer systems 

Notes

Funding information

This study was financially supported by the Ministry of Internal Affairs and Communications, Japan.

References

  1. 1.
    ICNIRP (1998) Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz). Health Phys 74(4):494–522Google Scholar
  2. 2.
    ICNIRP (2010) Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz). Health Phys 99(6):818–836Google Scholar
  3. 3.
    IEEE-C95.1 (2005) IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz, IEEE Std C95.1–2005 (Revision of IEEE Std C95.1–1991), pp. 1–238, 2006Google Scholar
  4. 4.
    Chakarothai J et al (2015) Exposure assessment of two different types of wireless power transfer systems at MHz-frequency band, BioEM 2015, Asiloma, California, USA, Jun 14–19, 2015Google Scholar
  5. 5.
    Laakso I, Tsuchida S, Hirata A, Kamimura Y (2012) Evaluation of SAR in a human body model due to wireless power transmission in the 10 MHz band. Phys Med Biol 57(15):4991–5002CrossRefGoogle Scholar
  6. 6.
    Park SW, Wake K, Watanabe S (2013) Incident electric field effect and numerical dosimetry for a wireless power transfer system using magnetically coupled resonances. IEEE Trans Microwave Theory Techn 61(9):3461–3469CrossRefGoogle Scholar
  7. 7.
    Chakarothai J, Kanako W, Watanabe S (2015) Evaluation of EM absorption characteristics in realistic adult and child models in vicinity of wireless power transfer systems, In: 2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC), pp. 448–451Google Scholar
  8. 8.
    Nadakuduti J, Douglas M, Lu L, Christ A, Guckian P, Kuster N (2015) Compliance testing methodology for wireless power transfer systems. IEEE Trans Power Electron 30(11):6264–6273CrossRefGoogle Scholar
  9. 9.
    Christ A, Chavannes N, Nikoloski N, Gerber HU, Pokovic K, Kuster N (2005) A numerical and experimental comparison of human head phantoms for compliance testing of mobile telephone equipment. Bioelectromagnetics 26(2):125–137CrossRefGoogle Scholar
  10. 10.
    Qishan Y, Gandhi OP, Aronsson M, Ding W (1999) An automated SAR measurement system for compliance testing of personal wireless devices. IEEE Trans Electromagn Compat 41(3):234–245CrossRefGoogle Scholar
  11. 11.
    IEC62209–1 (2005) Human exposure to radio frequency fields from hand-held and body-mounted wireless communications devices - Human models, instrumentation, and procedures. In: Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz). Geneva: IECGoogle Scholar
  12. 12.
    IEC62209–2 (2010) Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures. In: Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz). Geneva: IECGoogle Scholar
  13. 13.
    IEC TR62905 Ed. 1 (2017) Technical report on exposure assessment methods for wireless power transfer systems, Geneve, Switzerland, 2018Google Scholar
  14. 14.
    Pokovic K (1999) Advanced Electromagnetic Probes for Near-Field Evaluations. In: Doctor of Technical Sciences, Swiss Federal Institute of Technology ZurichGoogle Scholar
  15. 15.
    Chakarothai J, Wake K, Hamada L, Watanabe S (2015) SAR evaluation using human-equivalent liquid phantom in wireless power transfer frequency band. In: 2015 International Workshop on Electromagnetics: Applications and Student Innovation Competition (iWEM), pp. 1–2Google Scholar
  16. 16.
    Altair Engineering (2018) FEKO. [Online]Available at: http://www.altairhyperworks.jp/product/FEKO. Accessed 27 Jan 2018
  17. 17.
    Moré JJ (1977) The Levenberg-Marquardt algorithm: implementation and theory. In: Numerical analysis. Springer, pp. 105–116Google Scholar
  18. 18.
    Loader BG, Gregory AG., Bownds D (2009) Coaxial artefact standard for specific absorption rate 100 kHz to 400 MHz. In: PIERS Proceedings, Beijing, ChinaGoogle Scholar

Copyright information

© Institut Mines-Télécom and Springer Nature Switzerland AG 2018

Authors and Affiliations

  • Satoshi Shimoyama
    • 1
    • 2
  • Jerdvisanop Chakarothai
    • 1
    Email author
  • Kanako Wake
    • 1
  • Takuji Arima
    • 1
    • 2
  • Soichi Watanabe
    • 1
  • Toru Uno
    • 2
  1. 1.National Institute of Information and Communications TechnologyTokyoJapan
  2. 2.Tokyo University of Agriculture and TechnologyTokyoJapan

Personalised recommendations