Three-dimensional indices of renal perfusion in normal pregnancy and pre-eclampsia

  • Amanda Ali
  • Susan Addley
  • Stephen OngEmail author
Original Article
  • 30 Downloads

Abstract

Introduction

We compared renal perfusion in normal pregnant women and women with pre-eclampsia using three-dimensional (3D) ultrasound. We measured the flow index (FI), vascular index (VI) and vascularisation flow index (VFI) which are believed to reflect vascularity and flow intensity.

Methods

Fourteen patients with normal pregnancy and 16 patients with pre-eclampsia were recruited. Imaging was conducted using a Voluson E8 machine and a 6-MHz trans-abdominal probe. The inferior border of the maternal left kidney was scanned. Volumes were acquired using 3D power Doppler angiography (3D-PDA). The FI, VI and VFI were generated using ‘histogram’ facility.

Results

Maternal characteristics between normal pregnant women and women with pre-eclampsia were not different in terms of maternal age, gestation or body mass index. Depth of insonnation was not different between groups. The FI, VI and the VFI were not different between groups. The mean (SD) for FI was 27.9 (7.4) vs. 27.1 (6.5) between women with normal pregnancy vs. women with pre-eclampsia. For VI, mean (SD) was 72.3(31.6) vs. 79.4 (28.7) respectively. For VFI, mean (SD) was 20.8 (10.8) vs. 20.8 (8.1) respectively. Using the Mann-Whitney U test, no statistical differences between groups were apparent. There was no correlation between FI measurements and maternal creatinine (Pearson’s R square = 0.04; p = 0.45) or with maternal urea levels (Pearson’s R square = 0.20; p = 0.10).

Conclusion

Using 3D ultrasound, we failed to demonstrate a difference in maternal renal perfusion in normal pregnancy compared to pre-eclampsia. The lack of observed difference may be a reflection of the high variability in 3D measurements (i.e. poor investigative tool) rather than a true lack of difference in renal perfusion.

Keywords

3D ultrasound Pre-eclampsia Renal perfusion 

Notes

Author contribution

AA, SA and SO scanned the patients, performed the analysis of data and wrote the paper.

Compliance with ethical standards

Approval was granted from the Research Ethics committee and Research Governance department (Research Ethics number: 11/NI/0082. Research Governance number: 10113SO-FC).

Conflict of interest

The authors declare that they have no conflict of interest.

References

  1. 1.
    Karumanchi SA, Maynard SE, Stillman IE, Epstein FH, Sukhatme VP (2005) Preeclampsia: a renal perspective. Kidney Int 67(6):2101–2113CrossRefGoogle Scholar
  2. 2.
    Levine RJ, Lam C, Qian C, Yu KF, Maynard SE, Sachs BP, Sibai BM, Epstein FH, Romero R, Thadhani R, Karumanchi SA, CPEP Study Group (2006) Soluble endoglin and other circulating antiangiogenic factors in preeclampsia. N Engl J Med 355(10):992–1005CrossRefGoogle Scholar
  3. 3.
    Lam C, Lim KH, Karumanchi SA (2005) Circulating angiogenic factors in the pathogenesis and prediction of preeclampsia. Hypertension 46(5):1077–1085CrossRefGoogle Scholar
  4. 4.
    Bahser N, Godehardt E, Hess AP, Blume C (2014) Examination of intrarenal resistance indices indicate the involvement of renal pathology as a significant diagnostic classifier of preeclampsia. Am J Hypertens 27(5):742–749CrossRefGoogle Scholar
  5. 5.
    Nakai A, Asakura H, Oya A, Yokota A, Koshino T, Araki T (1999) Pulsed Doppler US findings of renal interlobar arteries in pregnancy-induced hypertension. Radiology 213(2):423–428CrossRefGoogle Scholar
  6. 6.
    Lafayette RA, Druzin M, Sibley R, Derby G, Malik T, Huie P, Polhemus C, Deen WM, Myers BD (1998) Nature of glomerular dysfunction in pre-eclampsia. Kidney Int 54(4):1240–1249CrossRefGoogle Scholar
  7. 7.
    Moran P, Baylis PH, Lindheimer MD, Davison JM (2003) Glomerular ultrafiltration in normal and preeclamptic pregnancy. J Am Soc Nephrol 14(3):648–652CrossRefGoogle Scholar
  8. 8.
    Raine-Fenning NJ, Nordin NM, Ramnarine KV, Campbell BK, Clewes JS, Perkins A, Johnson IR (2008) Determining the relationship between three-dimensional power Doppler data and true blood flow characteristics: an in-vitro flow phantom experiment. Ultrasound Obstet Gynecol 32(4):540–550CrossRefGoogle Scholar
  9. 9.
    Raine-Fenning NJ, Nordin NM, Ramnarine KV, Campbell BK, Clewes JS, Perkins A, Johnson IR (2008) Evaluation of the effect of machine settings on quantitative three-dimensional power Doppler angiography: an in-vitro flow phantom experiment. Ultrasound Obstet Gynecol 32(4):551–559CrossRefGoogle Scholar
  10. 10.
    Costa J, Rice H, Cardwell C, Hunter A, Ong S (2010) An assessment of vascularity and flow intensity of the placenta in normal pregnancy and pre-eclampsia using three-dimensional ultrasound. J Matern Fetal Neonatal Med 23(8):894–899CrossRefGoogle Scholar
  11. 11.
    Anbazhagan A, Ong S (2013) Hepatic portal vein flow and three dimensional indices of hepatic perfusion in pre-eclampsia compared with normal pregnancy. J Obstet Gynaecol 33(8):817–820CrossRefGoogle Scholar
  12. 12.
    Guiot C, Gaglioti P, Oberto M, Piccoli E, Rosato R (2008) Todros T. Is three-dimensional power Doppler ultrasound useful in the assessment of placental perfusion in normal and growth-restricted pregnancies? Ultrasound Obstet Gynecol 31(2):171–176CrossRefGoogle Scholar

Copyright information

© Royal Academy of Medicine in Ireland 2018

Authors and Affiliations

  1. 1.Fetal Medicine, Royal Jubilee Maternity HospitalBelfastUK

Personalised recommendations