Advertisement

Journal of Electronic Materials

, Volume 48, Issue 3, pp 1467–1471 | Cite as

Use of a GMR-SV Device Below a Single Coil and Channel to Detect the Deformation Properties of Red Blood Cell Membranes

  • Jong-Gu Choi
  • Jang-Roh Rhee
  • Sang-Suk LeeEmail author
5th International Conference of Asian Union of Magnetics Societies
  • 20 Downloads
Part of the following topical collections:
  1. 5th International Conference of Asian Union of Magnetics Societies (IcAUMS)

Abstract

A dual-type giant magnetoresistance-spin valve (GMR-SV) multilayer of Ta/NiFe/CoFe/Cu/CoFe/IrMn/CoFe/Cu/CoFe/NiFe/Ta was prepared by ion beam deposition. The bottom exchange coupling field (Hex) and coercivity (Hc), the top Hex and Hc, magnetoresistance (MR) ratio, and magnetic sensitivity (MS) of the as-grown sample were 480 Oe and 120 Oe, 240 Oe and 60 Oe, 6.3%, and 2.3%/Oe, respectively. The two electrodes of the GMR-SV device, a single turn coil of micrometer size, and a valley formed using a photoresist (PR) process to produce a channel of 10 μm as a biosensor were patterned by using a lithography process and an electron cyclotron resonance (ECR) Ar-ion milling system. The MR ratio and the MS of the patterned GMR-SV device were 3.5% and 0.88%/Oe, respectively. Computer simulations revealed that a single turn coil resulted in sufficient field strength to induce a magnetic field in the red blood cell (RBC)’s membrane of 12 Oe at an applied current of 10 mA. A valley channel, formed by the PR process, with a thickness of 10 μm and a width of 8 μm, occurred on the upper layer above the coil at the center of the GMR-SV device. Four types of RBCs, including normal circular and deformed elliptical membranes, were bonded to the edge and the central portion of the RBC due to the arrangement of the magnetic beads (MBs) with dipole moments. The differentially detected output signals of the normal and deformed RBC membranes, which were combined with MBs, were distributed the region of 530 μV.

Keywords

Dual-type GMR-SV single turn coil magnetic bead (MB) detecting signal deformation of membrane 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Notes

Acknowledgement

This work was supported by the National Research Foundation of Korea (NRF) funded by the Korean government (Ministry of Education) with Grant No. of NRF-2016R1D1A1B03936289.

References

  1. 1.
    M.D. Cubells-Beltrán, C. Reig, J. Madrenas, A.D. Marcellis, J. Santos, S. Cardoso, and P.P. Freitas, Sensors 16, 939 (2016).CrossRefGoogle Scholar
  2. 2.
    G. Li, S. Sun, R.J. Wilson, R.L. White, N. Pourmand, and S.X. Wang, Sens. Actuators A Phys. 126, 98 (2006).CrossRefGoogle Scholar
  3. 3.
    S.H. Park, K.S. Soh, M.C. Ahn, D.G. Hwang, and S.S. Lee, J. Korean Magn. Soc. 16, 157 (2006).CrossRefGoogle Scholar
  4. 4.
    S.S. Lee, S.H. Park, and K.S. Soh, New Phys. Sae Mulli 52, 564 (2006).Google Scholar
  5. 5.
    P. Khajidmaa and S.S. Lee, J. Korean Magn. Soc. 23, 193 (2013).CrossRefGoogle Scholar
  6. 6.
    P. Khajidmaa, K.J. Park, and S.S. Lee, J. Korean Magn. Soc. 23, 98 (2013).CrossRefGoogle Scholar
  7. 7.
    W.H. Lee, D.G. Hwang, and S.S. Lee, J. Magn. 14, 18 (2009).CrossRefGoogle Scholar
  8. 8.
    J.G. Choi, I.S. Koh, Y.M. Gong, M.H. Kim, Y.S. Park, D.G. Hwang, and S.S. Lee, J. Korean Magn. Soc. 19, 1 (2009).CrossRefGoogle Scholar
  9. 9.
    J.G. Choi and S.S. Lee, J. Korean Magn. Soc. 20, 41 (2010).CrossRefGoogle Scholar
  10. 10.
    J.G. Choi, S.S. Lee, and Y.S. Park, J. Korean Magn. Soc. 22, 173 (2012).CrossRefGoogle Scholar
  11. 11.
    J.G. Choi, S.H. Kim, and S.S. Lee, Advances in Experimental Medicine and Biology, ed. by O. Thews, J. LaManna, D.K. Harrison. Oxygen Transport to Tissue XL (In printed, Chap 55, 2018).Google Scholar
  12. 12.
    Y. Haik, V. Pai, and C.J. Chen, J. Magn. Magn. Mater. 194, 254 (1999).CrossRefGoogle Scholar
  13. 13.
    T. Takeuchi, T. Mizuno, T. Higashi, A. Yamagishi, and M. Date, J. Magn. Magn. Mater. 140–144, 1462 (1995).CrossRefGoogle Scholar
  14. 14.
    Y. Iiguni, M. Suwa, and H. Watarai, J. Chromatogr. A 1032, 165 (2004).CrossRefGoogle Scholar
  15. 15.
    J.G. Choi, H.M. Jung, and S.S. Lee, J. Magn. 22, 649 (2009).CrossRefGoogle Scholar
  16. 16.
    J.G. Choi, H.M. Jung, and S.S. Lee, J. Korean Magn. Soc. 27, 215 (2017).CrossRefGoogle Scholar

Copyright information

© The Minerals, Metals & Materials Society 2018

Authors and Affiliations

  1. 1.Department of Oriental Biomedical EngineeringSangji UniversityWonjuKorea
  2. 2.Department of NanophysicsSookmyung Women’s UniversitySeoulKorea

Personalised recommendations