Strength of Materials

, Volume 50, Issue 1, pp 137–145 | Cite as

Effect of a Nonuniform Radial/Axial Tip Clearance on the Flow Field in a Mixed-Flow Pump

  • W. Li
  • L. L. Ji
  • W. D. Shi
  • Y. F. Ping
  • L. Zhou
  • X. P. Jiang
Article
  • 8 Downloads

The effect of a nonuniform radial/axial tip clearance on the flow field in a mixed-flow pump was studied by numerical simulation of the unsteady flow in the pump with two tip clearance shapes using the standard Reynolds average Navier–Stokes turbulence model, and the equations were solved with the SIMPLEC computational algorithm. The external characteristics, distribution of static pressure, streamline flow of the tip clearance, and vorticity in the impeller are analyzed. The accuracy of numerical simulation was assessed by comparing experimental data with computational results. Although a nonuniform tip clearance leads to a decline in the pump head, which is more pronounced under part-load conditions, the configuration with a nonuniform tip clearance (c = 0.5–1 mm) provides the more uniform velocity and pressure distribution both in the circumferential and axial directions, as the leakage vortex intensity is weakened and its shedding is suppressed. The research results pointed the way for improving the unsteady flow in the mixed-flow pump.

Keywords

mixed-flow pump numerical simulation tip clearance tip leakage vortex 

Notes

Acknowledgments

This study was jointly supported by the National Natural Science Foundation of China (Nos. 51409127, 51679111, and 51579118), PAPD, Six Talents Peak Project of Jiangsu Province (No. HYZB-002); Key Research and Development Projects of Jiangsu Province of China (Nos. BE2015119 and BE2015001-4); the Natural Science Foundation of Jiangsu Province of China (No. BK20161472); and Scientific Research Start Foundation Project of Jiangsu University, China (No. 13JDG105).

References

  1. 1.
    M. Ou, W. Shi, W. Jia, and Q. Fu, “Numerical simulation and experimental validation on hydrodynamic radial force of mixed-flow pump impeller,” Trans. CSAE, 31, No. 9, 71–76 (2015).Google Scholar
  2. 2.
    R. F. Huang, X. W. Luo, B. Ji, et al., “Multi-objective optimization of a mixed-flow pump impeller using modified NSGA-II algorithm,” Sci. China Technol. Sc., 58, No. 12, 2122–2130 (2015).CrossRefGoogle Scholar
  3. 3.
    S. Shukla, A. K. Roy, and K. Kumar, “Material selection for blades of mixed-flow pump impeller using ANSYS,” Mater Today - Proc., 2, Nos. 4–5, 2022–2029 (2015).Google Scholar
  4. 4.
    Y. Senoo and M. Ishida, “Deterioration of compressor performance due to tip clearance of centrifugal impellers,” J. Turbomach., 109, No. 1, 55–61 (1987).CrossRefGoogle Scholar
  5. 5.
    S. S. Hong, M. Schleer, and R. S. Abhari, “Effect of tip clearance on the flow and performance of a centrifugal compressor,” Am. Soc. Mech. Eng., 1, 563–569 (2003).Google Scholar
  6. 6.
    C. Weiβ, D. R. Grates, H. Thermann, and R. Niehuis, “Numerical investigation of the influence of the ti clearance on wake formation inside a radial impeller,” Am. Soc. Mech. Eng., 6B, 681–691 (2003).Google Scholar
  7. 7.
    D. Wu, P. Yan, X. Chen, et al., “Effect of trailing-edge modification of a mixed-flow pump,” J. Fluids Eng., 137, No. 10, 101205 (2015).Google Scholar
  8. 8.
    H. Bing, L. Tan, S. L. Cao, and L. Lu, “Prediction method of impeller performance and analysis of loss mechanism for mixed-flow pump,” Sci China Technol. Sc., 55, No. 7, 1988–1998 (2012).CrossRefGoogle Scholar
  9. 9.
    K. Wang, H. Liu, X. Zhou, and W. Wang, “Experimental research on pressure fluctuation and vibration in a mixed-flow pump,” J. Mech. Sci. Technol., 30, No. 1, 179–184 (2016).CrossRefGoogle Scholar
  10. 10.
    J. L. Lu, P. C. Guo, J. J. Feng, and X. Q. Luo, “Experimental study on the flow of a mixed-flow pump impeller,” IOP Conf. Ser: Earth Environ. Sci., 15, No. 6, 062051 (2012).Google Scholar
  11. 11.
    R. Huang, B. Ji, X. Luo, et al., “Numerical investigation of cavitation-vortex interaction in a mixed-flow waterjet pump,” J. Mech. Sci. Technol., 29, No. 9, 3707–3716 (2015).CrossRefGoogle Scholar
  12. 12.
    M. Sedlář, J. Šoukal, T. Krátký, and M. Vyroubal, “Numerical prediction of impacts of cavitation in pumps for power generation,” Therm. Eng., 62, No. 6, 408–413 (2015).CrossRefGoogle Scholar
  13. 13.
    M. Sedlar, O. Sputa, and M. Komarek, “CFD analysis of cavitation phenomena in mixed-flow pump,” Int. J. Fluid Mach. Syst., 5, No. 1, 18–29 (2012).CrossRefGoogle Scholar
  14. 14.
    D. Bonaiuti, M. Zangeneh, R. Aartojarvi, and J. Eriksson, “Parametric design of a waterjet pump by means of inverse design, CFD calculations and experimental analyses,” J. Fluids Eng., 132, No. 3, 031104 (2010).Google Scholar
  15. 15.
    D. J. Kim, Y. U. Min, J. Y. Kim, and K. N. Chung, “A study of tip clearance effect for a mixed-flow pump on performance,” Am. Soc. Mech. Eng. (2003), DOI:  https://doi.org/10.1115/FEDSM2013-16346.
  16. 16.
    B. van Esch and L. Cheng, “Unstable operation of a mixed-flow pump and the influence of tip clearance,” Am. Soc. Mech. Eng. (2011), DOI: https://doi.org/10.1115/AJK2011- 06016.Google Scholar
  17. 17.
    A. Goto, “The effect of tip leakage flow on part-load performance of a mixed-flow pump impeller,” J. Turbomach., 114, No. 2, 383–391 (1992), DOI: https://doi.org/10.1115/ 1.2929155.Google Scholar
  18. 18.
    H. Bing, S. L. Cao, C. L. He, and L. Liu, “Experimental study of the effect of blade tip clearance and blade angle error on the performance of mixed-flow pump,” Sci. China Technol. Sc., 56, No. 2, 293–298 (2013).CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2018

Authors and Affiliations

  • W. Li
    • 1
  • L. L. Ji
    • 1
  • W. D. Shi
    • 1
  • Y. F. Ping
    • 1
  • L. Zhou
    • 1
  • X. P. Jiang
    • 1
  1. 1.National Research Center of Pumps and Pump SystemJiangsu UniversityZhenjiangChina

Personalised recommendations