Article

A prototype of a hydrogen generator with double selection of atoms by quantum state is developed. Results of measurements of the instability of the frequency of a hydrogen frequency standard based on this generator are presented.

Keywords

active hydrogen frequency standard system for double selection of atoms by quantum state adiabatic rapid passage frequency instability 

References

  1. 1.
    A. Claude, M. Desaintfuscient, P. Petit, and J.-P. Schermann, “Design of a double focalization in a hydrogen maser,” IEEE Trans. Instr. Mass, IM-17, No. 4, 351–353 (1968).Google Scholar
  2. 2.
    A. Boyko, G. Yolkin, N. Gestkova, G. Kurnikov, and V. Paramzin, “Hydrogen maser with improved short-term frequency stability,” in: Proc. 15th Europ. Frequency and Time Forum, Swiss Foundation for Research in Microtechnology, Neuchatel, Switzerland (2001), pp. 406–408.Google Scholar
  3. 3.
    E. M. Mattison, R. F. C. Vessot, and W. Shen, “Single-state selection system for hydrogen masers,” IEEE Trans. Ultrason., Ferroelect. Freq. Control, 34, Iss. 6, 622–628 (1987).ADSCrossRefGoogle Scholar
  4. 4.
    A. Abraham and B. Blini, Electronic Paramagnetic Resonance of Transition Ions [Russian translation], Mir, Moscow (1972), Vol. 1, pp. 111–125.Google Scholar
  5. 5.
    V. A. Polyakov, A. A. Belyaev, N. A. Demidov, and Yu. V. Timofeev, “Mathematical simulation of a system for selection of a beam of hydrogen atoms for the purpose of increasing the short-term frequency stability of a hydrogen generator,” Metrology of Time and Space: Proc. 6th Intern. Symposium, VNIIFTRI, Mendeleevo (2013), pp. 354–355.Google Scholar
  6. 6.
    V. A. Polyakov, N. A. Demidov, Yu. V. Timofeev, and A. V. Urutin, “A Hydrogen frequency standard with double selection of hydrogen atoms by energy state,” Metrology of Time and Space: Proc. 7th Intern. Symposium, VNIIFTRI, Mendeleevo (2014), pp. 100–102.Google Scholar
  7. 7.
    J. Vanier and C. Audoin, The Quantum Physics of Atomic Frequency Standards, IOP Publishing Ltd. Bristol and Philadelphia (1989).Google Scholar
  8. 8.
    D. Kleppner, H. C. Berg, J. B. Crampton, N. F. Ramsey, R. F. C. Vessot, H. E. Peters, and J. Vanier, “Hydrogen maser principles and techniques,” Phys. Rev., No. 5, 38 (1965).Google Scholar
  9. 9.
    A. A. Belyaev, N. A. Demidov, V. A. Polyakov, and Yu. V. Timofeev, “Estimation of a possible decrease in the limiting frequency instability of a hydrogen generator with the use of a beam of atoms in a single quantum state,” Izmer. Tekhn., No. 8, 28–31 (2018).Google Scholar
  10. 10.
    V. A. Polyakov, A. A. Belyaev, N. A. Demidov, and Yu. V. Timofeev, “A system of double selection of atoms by quantum state for an industrial hydrogen frequency standard,” Izmer. Tekhn., No. 8, 31–35 (2018).Google Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2018

Authors and Affiliations

  • Yu. V. Timofeev
    • 1
  • V. A. Polyakov
    • 1
  • A. A. Belyaev
    • 1
  • N. A. Demidov
    • 1
  1. 1.Vremya-Ch CompanyNizhnii NovgorodRussia

Personalised recommendations