Advertisement

A charge accumulation-free voltage-controlled functional electrical stimulator with bi-phasic sinusoidal stimulation

  • Wei-Hsien Chen
  • Chia-Hung ChangEmail author
  • Horng-Yuan Shih
  • Tzai-Wen Chiu
  • Chien-Nan Kuo
Article
  • 3 Downloads

Abstract

This paper presents a charge accumulation-free voltage-controlled (VC) bi-phasic sinusoidal functional electrical stimulator (FES) for bioelectronic application. Traditionally, constant current (CC) pulse-shaped FESs with active or passive charge balancers are used to compensate for accumulated charges arise from process, voltage and temperature (PVT) variation as a result of long-term stimulation. Unlike the CC pulse-shaped FES, the VC sinusoidal-shaped FES is adopted here to avoid charge accumulation over time. The charge balancer is not required, substantially reducing system complexity and the chip area of the FES. To demonstrate the feasibility of concept, in this paper, four channels of VC bi-phasic sinusoidal-shaped FESs are integrated with the bio-potential recording circuit to compare with four channels of CC bi-phasic pulse-shaped FESs that are integrated with the same neural recording system for comparison. Measurements indicate an absence of charge accumulation as a result of the VC FESs. In addition, here we adopt the sinusoidal stimulation to reduce transient effects on tissue in comparison to a pulse-shaped method. The bio-potential activities of a cockroach leg that is stimulated for 50 s by the proposed bi-phasic sinusoidal stimulation are recorded. The measured bio-potential activities of a cockroach leg show that no stimulation-evoked leg movement occurs under stimulation by the sinusoidal waveform.

Keywords

Bioelectronics Charge accumulation-free Voltage-controlled Functional electrical stimulator Bi-phasic Sinusoidal 

Notes

References

  1. 1.
    Song, K. et al. (2012). A sub-10nA DC-balance adaptive stimulator IC with multimodal sensor for compact electro-acupuncture system. In ISSCC Digest of Technical Papers (pp. 296–297).Google Scholar
  2. 2.
    Liu, W. (2004). Retinal prosthesis. In ISSCC Digest of Technical Papers (pp. 218–219).Google Scholar
  3. 3.
    Sivaprakasam, M., et al. (2005). A variable range bi-phasic current stimulus driver circuitry for an implantable retinal prosthetic device. IEEE Journal of Solid-State Circuits, 40, 763–771.CrossRefGoogle Scholar
  4. 4.
    Lin, C. W. et al. (2010). Pain control on demand based on pulsed radio-frequency stimulation of the dorsal root ganglion using a batteryless implantable CMOS SoC. In ISSCC Digest of Technical Papers (pp. 234–235).Google Scholar
  5. 5.
    Lee, H.-M., Park, H., & Ghovanloo, M. (2013). A power-efficient wireless system with adaptive supply control for deep brain stimulation. IEEE Journal of Solid-State Circuits, 48, 2203–2216.CrossRefGoogle Scholar
  6. 6.
    Noorsal, E., et al. (2012). A neural stimulator frontend with high-voltage compliance and programmable pulse shape for epiretinal implants. IEEE Journal of Solid-State Circuits, 47, 244–256.CrossRefGoogle Scholar
  7. 7.
    Butz, N. et al. (2016). A 22 V compliant 56 µW active charge balancer enabling 100% charge compensation even in monophasic and 36% amplitude correction in biphasic neural stimulators. In ISSCC Digest of Technical Papers (pp. 390–391).Google Scholar
  8. 8.
    Petrofsky, J., et al. (2009). The transfer of current through skin and muscle during electrical stimulation with sine, square, russian and interferential waveforms. Journal of Medical Engineering & Technology, 33, 170–181.CrossRefGoogle Scholar
  9. 9.
    Mandal, S. K. (2009). Low dropout regulator with stability compensation. U.S. Patent 7589507.Google Scholar
  10. 10.
    Experiment: The dancing cockroach leg-microstimulation of neurons and muscles. https://backyardbrains.com/experiments/microstimulation. Accessed 3 Sept 2018.
  11. 11.
    Kassiri, H. et al. (2017). All-wireless 64-channel 0.013 mm2/ch closed-loop neurostimulator with rail-to rail DC offset removal. In ISSCC Digest of Technical Papers (pp. 452–453).Google Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2019

Authors and Affiliations

  1. 1.Department of Electronics EngineeringNational Chiao-Tung UniversityHsinchuTaiwan, ROC
  2. 2.Department of Electrical EngineeringFeng Chia UniversityTaichungTaiwan, ROC
  3. 3.Department of Electrical EngineeringTamkang UniversityNew Taipei CityTaiwan, ROC
  4. 4.Department of Biological Science and TechnologyNational Chiao-Tung UniversityHsinchuTaiwan, ROC