This paper presents a microwave system for heartbeat rate measurement. This system is based on using a vector network analyzer and horn antennas. The system generates a continuous wave signal toward a person’s chest then the reflected signal is analyzed. The phase difference between the emitted and the reflected signals contains information about the chest movement; hence, the heartbeat rate can be extracted. In this work, several scenarios for detecting the heart activity are considered. The first scenario aims to provide a comparative study for using single-antenna and two-antennas microwave systems. Several radiated powers are considered in this scenario. Simultaneously with the microwave system, a wireless electrocardiograph is used as reference in order to determine the accuracy of the system. Measurements are performed in both cases when breathing normally and when holding the breath. The second scenario aims to test the ability of detecting the heartbeat activity of a person while moving. Measurements are performed while the subject walks towards the radar. Modeling is used for this purpose. The operating frequency used is 20 GHz in both scenarios. Signals are processed using wavelet transform and results show the ability to extract the heartbeat rate even with the presence of body movement.

Keywords

Single-antenna microwave system Two-antennas microwave system Moving person Electrocardiograph Heartbeat rate Signal processing Wavelet decomposition 

References

  1. 1.
    Lin, J. C., Kiernicki, J., Kiernicki, M., & Wollschlaeger, P. B. (1979). Microwave apexcardiography. IEEE Transactions on Microwave Theory and Techniques, 27(6), 618–620.CrossRefGoogle Scholar
  2. 2.
    Rahman, A., Yavari, E., Xiaomeng, G., Lubecke, V., & Boric-Lubecke, O. (2015). Signal processing techniques for vital sign monitoring using mobile short range Doppler radar. In IEEE conference on biomedical wireless technologies, networks, and sensing systems (BioWireleSS) (pp. 1–3). San Diego, CA.Google Scholar
  3. 3.
    Wang, Y., Yang, Y., & Fathy, A. E. (2009). Reconfigurable ultra-wide band see-through-wall imaging radar system. In IEEE antennas and propagation society international symposium (pp. 1–4). North Charleston, SC, USA.Google Scholar
  4. 4.
    He, M., Nian, Y., & Gong, Y. (2017). Novel signal processing method for vital sign monitoring using FMCW radar. Journal in Biomedical Signal Processing and Control, 33, 335–345.CrossRefGoogle Scholar
  5. 5.
    Crocco, L., & Ferrara, V. (2014). A review on ground penetrating radar technology for the detection of buried or trapped victims. In IEEE International conference on collaboration technologies and systems (CTS) (pp. 535–540). Minneapolis.Google Scholar
  6. 6.
    Lu, L., Li, C., & Rice, J. A. (2011). A software-defined multifunctional radar sensor for linear and reciprocal displacement measurement. In Wireless sensors and sensor networks (WiSNet). IEEE topical conference. Phoenix, AZ, USA.Google Scholar
  7. 7.
    Gu, C., Li, R., Li, C., Jiang, S. -B. (2011). Doppler radar respiration measurement for gated lung cancer radiotherapy. In Biomedical wireless technologies. Networks, and sensing systems (BioWireleSS) (pp. 91–94). Phoenix, AZ, USA.Google Scholar
  8. 8.
    Boric-Lubecke, O., Droitcour, A. D., Lubecke, V. M., Lin, J., & Kovacs G. T. A. (2003). Wireless IC doppler for sensing of heart and respiration activity. In IEEE TELSIKS 2003, Serbia and Montenegro, Nis (pp. 337–344).Google Scholar
  9. 9.
  10. 10.
    Obeid, D., Sadek, S., Zaharia, G., & El Zein, G. (2009). Noncontact heartbeat detection at 2.4, 5.8 and 60 GHz: A comparative study. Microwave and Optical Technology Letter, 51(3), 666–669.CrossRefGoogle Scholar
  11. 11.
    Obeid, D., Zaharia, G., Sadek, S., & El Zein, G. (2011). ECG vs. single-antenna system for heartbeat activity detection. In 4th international symposium on applied sciences in biomedical and communication technologies (ISABEL). Barcelona, Spain.Google Scholar
  12. 12.
    American National Standard, Cardiac monitors, heart rate meters, and alarms, ANSI/AAMI EC1.Google Scholar
  13. 13.
    El-Samad, S., Obeid, D., Zaharia, G., Sadek, S., & El Zein, G. (2014). Contact-Less measurement system or cardiopulmonary activity. In Proceedings of 2014 Mediterranean microwave symposium (MMS), 2014. Marrakech.Google Scholar
  14. 14.
    Motard, R., Joseph, B. (1994). Wavelet application in chemical engineering. Springer: Washington University in St. Louis.  https://doi.org/10.1007/978-1-4615-2708-4.
  15. 15.
    Blackburn, A., & Ferwerda, J. G. (2008). Retrieval of chlorophyll concentration from leaf reflectance spectra using wavelet analysis. Remote Sensing of Environment, 112(4), 1614–1632.CrossRefGoogle Scholar
  16. 16.
    Stolojescu C., Railean, I., Moga, S., & Isar, A. (2010). Comparison of wavelet families with application to WiMAX traffic forecasting. In International conference on optimization of electrical and electronic equipment. Brasov, Romania.Google Scholar
  17. 17.
    Hao, P. (2009). Reversible resampling of integer signals. IEEE Transactions on Signal Processing, 57(2), 516–525.MathSciNetCrossRefMATHGoogle Scholar
  18. 18.
    Chen, K.-M., Huang, Y., Zhang, J., & Norman, A. (2000). Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier. IEEE Transaction in Biomedical Engineering, 27(1), 105–114.CrossRefGoogle Scholar
  19. 19.
    Petkie, D. T., Benton, C., & Bryan, E. (2009). Millimeter wave radar for remote measurement of vital signs. In IEEE radar conference (pp. 1–3).Google Scholar
  20. 20.
    Nasr, I., Karagozler, E., Poupyrev, I., & Trotta, S. (2015). A highly integrated 60-GHz 6-Channel transceiver chip in 0.35 μm SiGe technology for smart sensing and short-range communications. In IEEE compound semiconductor integrated circuit symposium (CSICS) (pp. 1–4). New Orleans, LA, USA.Google Scholar
  21. 21.
    Tu, J., Hwang, T., & Lin, J. (2016). Respiration rate measurement under 1-D body motion using single continuous-wave Doppler radar vital sign detection system. IEEE Transactions on Microwave Theory and Techniques, 64(6), 1937–1946.CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2018

Authors and Affiliations

  1. 1.Doctoral School of Science and TechnologyLebanese UniversityBeirutLebanon
  2. 2.Univ Rennes, INSA Rennes, CNRS, IETR (Institut d’Electronique et de Telecommunications de Rennes) UMR 6164RennesFrance

Personalised recommendations