A new radiographic acetabular cup anteversion measurement method in total hip arthroplasty: a clinical study

  • G. Saka
  • G. AltunEmail author
  • H. Burc
  • M. Aydogan
Original Article • HIP - ARTRHOPLASTY

Abstract

Background

The acetabular cup positioning is one of the most crucial steps affecting stability and wear rates in total hip arthroplasty. Different methods have been described for determining the anteversion of the acetabular cup in the literature. But there is still not a widely accepted method to assess the acetabular anteversion radiography. The aim of this study is to measure the acetabular anteversion angle on a single pelvis AP radiography with our method which was proven with an experimental study before.

Materials and methods

A total of 15 patients (8 males, 7 females) who underwent total hip arthroplasty and have had a pelvis computed tomography scans in our outpatient clinic were evaluated retrospectively. The anteversion angle was calculated in all of pelvis CT scans. For radiological measurement, the formula defined by the authors in an experimental model previously was used.

Results

Statistically significant difference was not determined between radiographic and CT-based measurements (p = 0.207; p > 0.05). A statistically significant agreement was observed at a level of 98.8% between radiographic and CT-based measurements (ICC = 0.988; 95% CI 0.966–0.996; p < 0.01).

Conclusion

Assessment of the acetabular cup anteversion is very important to predict the possible complications after total hip arthroplasty. Although many methods have been defined for this purpose, each of these has advantages and disadvantages. In particular, with computed tomography method, the patient is exposed to excessive radiation, whereas we think that our method is a preferred method due to features not requiring additional equipment, low radiation exposure, being simple, cost-effectiveness, easily applicable and almost 100% accurate.

Keywords

Acetabulum Anteversion Radiography Total hip arthroplasty 

Notes

Compliance with ethical standards

Conflict of interest

All authors declare that they have no conflict of interest.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors.

References

  1. 1.
    Brew CJ, Simpson PM, Whitehouse SL, Donnelly W, Crawford RW, Hubble MJ (2012) Scaling digital radiographs for templating in total hip arthroplasty using conventional acetate templates independent of calibration markers. J Arthroplast 27(4):643–647.  https://doi.org/10.1016/j.arth.2011.08.002 CrossRefGoogle Scholar
  2. 2.
    Steinberg EL, Shasha N, Menahem A, Dekel S (2010) Preoperative planning of total hip replacement using the TraumaCad system. Arch Orthop Trauma Surg 130(12):1429–1432.  https://doi.org/10.1007/s00402-010-1046-y CrossRefGoogle Scholar
  3. 3.
    Jaramaz B, DiGioia AM, Blackwell M et al (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop Relat Res 354:70–81CrossRefGoogle Scholar
  4. 4.
    Olivecrona H, Weidenhielm L, Olivecrona L et al (2004) A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients. Acta Orthop Scand 75(3):252–260.  https://doi.org/10.1080/00016470410001169 CrossRefGoogle Scholar
  5. 5.
    Pradhan R (1999) Planar anteversion of the acetabular cup as determined from plain antero-posterior radiographs. J Bone Jt Surg Br 81(3):431–435CrossRefGoogle Scholar
  6. 6.
    Visser JD, Konings JG (1981) A new method for measuring angles after total hip arthroplasty: a study of the acetabular cup and femoral component. J Bone Jt Surg Br 63(B(4)):556–559CrossRefGoogle Scholar
  7. 7.
    Ghelmam B, Kepler C, Lyman S et al (2009) CT outperforms radiography for determination of acetabular cup version after THA. Clin Orthop Relat Res 467(9):2362–2370.  https://doi.org/10.1007/s11999-009-0774-1 CrossRefGoogle Scholar
  8. 8.
    Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J (2006) Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 58(2):294–300.  https://doi.org/10.1016/j.ejrad.2005.10.003 CrossRefGoogle Scholar
  9. 9.
    Penenberg BL, Samagh SP, Rajaee SS, Woehnl A, Brien WW (2018) Digital radiography in total hip arthroplasty: technique and radiographic results. J Bone Jt Surg Am 100(3):226–235.  https://doi.org/10.2106/JBJS.16.01501 CrossRefGoogle Scholar
  10. 10.
    Seo H, Naito M, Nakamura Y, Kinoshita K, Nomura T, Minokawa S, Minamikawa T, Yamamoto T (2017) New cross-table lateral radiography method for measuring acetabular component anteversion in total hip arthroplasty: a prospective study of 93 primary THA. Hip Int 27(3):293–298.  https://doi.org/10.5301/hipint.5000456 CrossRefGoogle Scholar
  11. 11.
    Widmer KH (2004) A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplast 19(3):387–390CrossRefGoogle Scholar
  12. 12.
    Derbyshire Brian, Raut Videshnandan V (2013) The efficacy of a“double-D-shaped” wire marker for radiographic measurement of acetabular cup orientation and wear. Hip Int 23(6):546–551.  https://doi.org/10.5301/hipint.5000038 CrossRefGoogle Scholar
  13. 13.
    Aydogan M, Burc H, Saka G (2014) A new method for measuring the anteversion of the acetabuler cup after total hip arthroplasty. Eur J Orthop Surg Traumatol 24(6):897–903.  https://doi.org/10.1007/s00590-013-1353-4 CrossRefGoogle Scholar
  14. 14.
    Sculco PK, McLawhorn AS, Carroll KM, McArthur BA, Mayman DJ (2016) Anteroposterior radiographs are more accurate than cross-table lateral radiographs for acetabular anteversion assessment: a retrospective cohort study. HSS J 12:32–38.  https://doi.org/10.1007/s11420-015-9472-6 CrossRefGoogle Scholar
  15. 15.
    Zingg M, Boudabbous S, Hannouche D, Montet X, Boettner F (2017) Standardized fluoroscopy-based technique to measure intraoperative cup anteversion. J Orthop Res 35(10):2307–2312.  https://doi.org/10.1002/jor.23514 CrossRefGoogle Scholar
  16. 16.
    Boettner F, Zingg M, Emara AK, Waldstein W, Faschingbauer M, Kasparek MF (2017) The accuracy of acetabular component position using a novel method to determineanteversion. J Arthroplast 32(4):1180–1185.  https://doi.org/10.1016/j.arth.2016.10.004 CrossRefGoogle Scholar
  17. 17.
    Nunley RM, Keeney JA, Zhu J, Clohisy JC, Barrack RL (2011) The reliability and variation of acetabular component anteversion measurements from cross-table lateral radiographs. J Arthroplast 26(6 Suppl):84–87.  https://doi.org/10.1016/j.arth.2011.03.039 CrossRefGoogle Scholar
  18. 18.
    Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Jt Surg Am 60(2):217–220CrossRefGoogle Scholar
  19. 19.
    Dorr LD, Malik A, Wan Z, Long WT, Harris M (2007) Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orth Relat Res 465:92–99.  https://doi.org/10.1097/BLO.0b013e3181560c51 Google Scholar
  20. 20.
    Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullmann W, Zweymüller K (2007) Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements. J Arthroplast 22(6):812–817.  https://doi.org/10.1016/j.arth.2006.10.001 CrossRefGoogle Scholar
  21. 21.
    Fukunishi S, Fukui T, Imamura F, Nishio S (2008) Assessment of accuracy of acetabular cup orientation in CT-free navigated total hip arthroplasty. Orthopedics.  https://doi.org/10.3928/01477447-20110525-13 Google Scholar

Copyright information

© Springer-Verlag France SAS, part of Springer Nature 2019

Authors and Affiliations

  1. 1.Department of Orthopaedics and TraumatologyHisar İntercontinental HospitalIstanbulTurkey
  2. 2.Department of Orthopedics and TraumatologyÜmraniye Research and Education HospitalIstanbulTurkey
  3. 3.Department of Orthopedics and TraumatologyBeykent University Faculty of MedicineIstanbulTurkey
  4. 4.Department of Orthopedics and TraumatologyBosphorus Spine CenterIstanbulTurkey

Personalised recommendations