Advertisement

Increasing sensing distance of passive wireless IOP sensor

  • Bahram Azizollah Ganji
  • Shirin Azadi Kenari
  • Samaneh Soleimani Amiri
Technical Paper

Abstract

Continuous intraocular pressure monitoring is very necessary for glaucoma patients. In this paper, a passive wireless intraocular pressure (IOP) sensor using an inductively coupled wireless sensing technique is presented. IOP sensor is consist of a multipath circular spiral coil inductor, variable capacitor and a SU-8 pressure sensitive diaphragm. Capacitor and inductor of sensor are made of high-conductivity and biocompatible metal gold that are encapsulated inside biocompatible SU-8 to prevent damage to eye tissue. By measuring impedance phase dip frequency shift from the external reader coil, the intraocular pressure signal is obtained from the IOP sensor. Small size of the sensor coil due to the biological constrains reduces the sensing distance. The purpose of this paper is increasing the quality factor of sensor coil using the multipath technique in order to enhancement of sensing distance. Simulation has been taken using COMSOL Multiphysics and ADS software. The proposed structure, due to its small size could increase the sensing distance. The dimension of proposed wireless sensor and sensing distance is \( 2.5\;{\text{mm }} \times 2.5\;{\text{mm}} \) and 2 cm, respectively, that has a larger sensing distance and smaller size compared with previous works and its sensitivity is 4281 ppm/mmHg.

Notes

References

  1. Akar O, Akin T, Najafi K (2001) A wireless batch sealed absolute capacitive pressure sensor. Sens Actuator A 95:29–38CrossRefGoogle Scholar
  2. Chen Ji, Liou Juin J (2004) On-chip spiral inductors for RF applications: an overview. J Semicond Technol Sci 4(3):149–167Google Scholar
  3. Chen PJ, Rodger DC, Saati S, Humayun MS, Tai YC (2008) Microfabricated implantable parylene-based wireless passive intraocular pressure sensors. J Microelectromech Syst 17(6):1342–1351CrossRefGoogle Scholar
  4. Chen PJ, Saati S, Varma R, Humayun MS, Tai YC (2010) Wireless intraocular pressure sensing using microfabricated minimally invasive flexible-coiled LC sensor implant. J Microelectromech Syst 19(4):721–734CrossRefGoogle Scholar
  5. Chitnis G, Maleki T, Samuels B, Cantor LB, Ziaie B (2013) A minimally invasive implantable wireless pressure sensor for continuous IOP monitoring. IEEE Trans Biomed Eng 60(1):250–256CrossRefGoogle Scholar
  6. Crum B, Li W (2013) Parylene-based fold-and-bond wireless pressure sensor. In: Nano/micro engineered and molecular systems (NEMS), pp 1155–1158Google Scholar
  7. Ehlers N, Bramsen T, Sperling S (1975) Applanation tonometry and central corneal thickness. Acta Ophthalmol 53:34CrossRefGoogle Scholar
  8. Finkenzeller K (2003) RFID handbook. Wiley, HobokenCrossRefGoogle Scholar
  9. Ganji BA, Molanzadeh M (2017) High performance planar micro-transformer using novel crossover connection. Microsyst Technol 23(10):4413–4420CrossRefGoogle Scholar
  10. Ganji BA, Shahiri-Tabarestani M (2013) A novel high sensitive MEMS intraocular capacitive pressure sensor. Microsyst Technol 19:187–194CrossRefGoogle Scholar
  11. Gloster J, Perkins ES (1963) The validity of the Imbert-Flick law as applied to applanation tonometry. Exp Eye Res 44:274–283CrossRefGoogle Scholar
  12. Greene ME, Gilman BG (1974) Intraocular pressure measurement with instrumented contact lens. Invest Ophthalmol 13:299–302Google Scholar
  13. Katuri KC, Asrani S, Ramasubramanian MK (2008) Intraocular pressure monitoring sensors. IEEE Sens J 8(1):12–19CrossRefGoogle Scholar
  14. KC Katuri, MK Ramasubramanian, S Asrani (2010) A surface micromachined capacitive pressure sensor for intraocular pressure measurement. In: Mechatronics and embedded systems and applications (MESA), pp 149–154Google Scholar
  15. Leonardi M, Leuenberger P, Bertrand D, Bertsch A, Renaud P (2004) First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens. Invest Ophthalmol Vis Sci 45(9):3113–3117CrossRefGoogle Scholar
  16. Lin CH, Zhao Y, Chen PJ, Humayun M, Tai Y (2012a) A parylene-based intraocular pressure sensor. IEEE Nanotechnol Mag 6:8–16CrossRefGoogle Scholar
  17. Lin JCH, Zhao Y, Chen PJ, Tai YC (2012) High quality factor parylene-based intraocular pressure sensor. In: Nano/micro engineered and molecular systems (NEMS), pp 137–140Google Scholar
  18. Moses RA (1958) The goldmann applanation tonometer. Am J Ophthalmol 46:865–869CrossRefGoogle Scholar
  19. Park J, Kim JK, Patil SJ, Park JK, Park SA, Lee DW (2016) A wireless pressure sensor integrated with a biodegradable polymer stent for biomedical applications. Sensors 16:809CrossRefGoogle Scholar
  20. Rosengren L, Backlund Y, Sjostrom T, Hok B, Svedbergh B (1992) A system for wireless intra-ocular pressure measurements using a silicon micromachined sensor. J Micromech Microeng 2(3):202–204CrossRefGoogle Scholar
  21. Timoshenko S, Woinowsky-Krieger S, Woinowsky S (1959) Theory of plates and shells, vol 2. McGraw-Hill, New YorkzbMATHGoogle Scholar
  22. Walter P (2002) Intraocular pressure sensor: where are we—where will we go? Graefe’s Arch Clin Exp Ophthalmol 240:335–336CrossRefGoogle Scholar
  23. Xu X, Li P, Cai M, Han B (2012) Design of novel high-Q-factor multipath stacked on-chip spiral inductors. IEEE Trans Electron devices 59(8):2011–2018CrossRefGoogle Scholar
  24. Xue N, Chang SP, Lee JB (2012) A SU-8-based microfabricated implantable inductively coupled passive RF wireless intraocular pressure sensor. J Microelectromech Syst 21(6):1338–1346CrossRefGoogle Scholar
  25. Zheng C, Li W, Li AL, Zhan Z, Wang LY, Sun DH (2016) Design and manufacturing of a passive pressure sensor based on LC resonance. Micromachines.  https://doi.org/10.3390/mi7050087 CrossRefGoogle Scholar

Copyright information

© Springer-Verlag GmbH Germany, part of Springer Nature 2018

Authors and Affiliations

  1. 1.Department of Electrical EngineeringBabol Noshirvani University of TechnologyBabolIran