Impact of segmentation density on spectral domain optical coherence tomography assessment in Stargardt disease

  • Swetha Bindu Velaga
  • Muneeswar Gupta Nittala
  • Dennis Jenkins
  • J. Melendez
  • Alexander Ho
  • R. W. Strauss
  • H. P. Scholl
  • SriniVas R. SaddaEmail author
Retinal Disorders
  • 21 Downloads

Abstract

Purpose

Automated spectral domain optical coherence tomography (SD-OCT) segmentation algorithms currently do not perform well in segmenting individual intraretinal layers in eyes with Stargardt disease (STGD). We compared selective B-scan segmentation strategies for generating mean retinal layer thickness and preserved area data from SD-OCT scans in patients with STGD1.

Methods

Forty-five eyes from 40 Stargardt patients were randomly selected from the ongoing Natural History of the Progression of Atrophy Secondary to Stargardt Disease (ProgStar) study. All eyes underwent SD-OCT using a standard macular volume consisting of 1024 × 49 equally spaced B-scans within a 20 × 20 degree field centered on the fovea. All 49 B-scans were segmented manually to quantify total retina, outer nuclear layer (ONL), photoreceptor inner segments, photoreceptor outer segments (OS), and retinal pigment epithelial layer (RPE). Mean thickness and total area were generated using all 49 B-scans (spaced 122 μm apart), 25 B-scans (every other B-scan, spaced 240 μm apart), 17 B-scans (every third scan, 353 μm apart), and 13 B-scans (every fourth scan, 462 μm apart), as well as by using an “adaptive” method where a subset (minimum 25 B-scans) of B-scans that the grader deemed as significantly different from adjacent B-scans were utilized. Mean absolute and percentage errors were calculated for macular thickness and area of different retinal layers for the different B-scan subset selection strategies relative to using all 49 B-scans, which was considered the reference or ground truth.

Results

Mean thickness and area measurements were significantly different for any regularly spaced reduction in B-scan density relative to the ground truth. When an adaptive approach was applied using a minimum of half the scans, the differences relative to ground truth were no longer significantly different. The mean percent differences for the area and thicknesses of the various layers ranged from 0.02 to 33.66 (p < 0.05 for all comparisons) and 0.44 to 7.24 (p > 0.05) respectively.

Conclusion

Manual segmentation of a subset of B-scans using an adaptive strategy can yield thickness and area measurements of retinal sublayers comparable to the reference ground truth derived from using all B-scans in the volume. These results may have implications for increasing the efficiency of SD-OCT grading strategies in clinical trials for STGD and other related macular degenerative disorders.

Keywords

Stargardt Segmentation density Spectral domain optical coherence tomography Retinal layers 

Notes

Compliance with ethical standards

Data collection and analyses were approved by the Institutional Review Board of the University of California Los Angeles

Conflict of interest

Dr. Sadda receives research support from Carl Zeiss Meditec, Optos, and serves as a consultant to Optos, Heidelberg, and Centervue. Other authors have no financial disclosures.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Informed consent was obtained from all individual participants included in the study.

References

  1. 1.
    Sadda SR, Wu Z, Walsh AC et al (2005) Errors in retinal thickness measurements obtained by optical coherence. Tomography:285–293.  https://doi.org/10.1016/j.ophtha.2005.10.005
  2. 2.
    Sadda SR, Keane PA, Ouyang Y et al (2010) Impact of scanning density on measurements from spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci 51:1071–1078.  https://doi.org/10.1167/iovs.09-4325 CrossRefGoogle Scholar
  3. 3.
    Strauss RW, Ho A, Muñoz B et al (2016) The natural history of the progression of atrophy secondary to Stargardt disease ( ProgStar ) studies design and baseline characteristics : ProgStar report no. 1. Ophthalmology:1–12.  https://doi.org/10.1016/j.ophtha.2015.12.009
  4. 4.
    Ritter M, Zotter S, Schmidt WM et al (2016) Characterization of Stargardt disease using polarization- sensitive optical coherence tomography and fundus autofluorescence imaging.  https://doi.org/10.1167/iovs.12-11550
  5. 5.
    Strauss RW, Muñoz B, Wolfson Y et al (2015) Assessment of estimated retinal atrophy progression in Stargardt macular dystrophy using spectral- domain optical coherence tomography:1–7.  https://doi.org/10.1136/bjophthalmol-2015-307035
  6. 6.
    Park JC, Collison FT, Fishman GA et al (2015) Objective analysis of hyperreflective outer retinal bands imaged by optical coherence tomography in patients with stargardt disease. Investig Ophthalmol Vis Sci 56:4662–4667.  https://doi.org/10.1167/iovs.15-16955 CrossRefGoogle Scholar
  7. 7.
    Nittala MG, Konduru R, Ruiz-Garcia H, Sadda SR (2011) Effect of OCT volume scan density on thickness measurements in diabetic macular edema. Eye (London, England) 25:1347–1355.  https://doi.org/10.1038/eye.2011.173 CrossRefGoogle Scholar
  8. 8.
    Velaga S, Nittala M, Parinitha B et al (2016) Correlation between retinal sensitivity and cystoid space characteristics in diabetic macular edema. Indian J Ophthalmol 64:452.  https://doi.org/10.4103/0301-4738.187675 CrossRefGoogle Scholar
  9. 9.
    Velaga SB, Nittala MG, Konduru RK, et al (2016) Impact of optical coherence tomography scanning density on quantitative analyses in neovascular age-related macular degeneration. Eye (London). doi:  https://doi.org/10.1038/eye.2016.260
  10. 10.
    Keane PA, Liakopoulos S, Jivrajka R V, et al (2016) Evaluation of optical coherence tomography retinal thickness parameters for use in clinical trials for Neovascular age-related macular degeneration AND. 3378–3385.  https://doi.org/10.1167/iovs.08-2728

Copyright information

© Springer-Verlag GmbH Germany, part of Springer Nature 2019

Authors and Affiliations

  • Swetha Bindu Velaga
    • 1
  • Muneeswar Gupta Nittala
    • 1
  • Dennis Jenkins
    • 1
  • J. Melendez
    • 1
  • Alexander Ho
    • 1
  • R. W. Strauss
    • 2
    • 3
    • 4
    • 5
  • H. P. Scholl
    • 2
  • SriniVas R. Sadda
    • 1
    • 6
    Email author
  1. 1.Doheny Eye InstituteLos AngelesUSA
  2. 2.Wilmer Eye InstituteJohns Hopkins UniversityBaltimoreUSA
  3. 3.Moorfield’s Eye Hospital NHS Foundation Trust and UCL Institute of OphthalmologyUniversity College LondonLondonUK
  4. 4.Department of OphthalmologyMedical University GrazGrazAustria
  5. 5.Department of OphthalmologyJohannes Kepler University LinzLinzAustria
  6. 6.Department of OphthalmologyDavid Geffen School of Medicine at UCLALos AngelesUSA

Personalised recommendations