Correction to: CT screening for lung cancer: comparison of three baseline screening protocols
- 39 Downloads
Correction to: European Radiology
https://doi.org/10.1007/s00330-018-5857-5
Recommendations for each protocol by NCN subtype and size on the baseline LDCT for (a) immediate workup, (b) 3-month follow-up LDCT, and (c) 6-month follow-up LDCT
I-ELCAP | ACR-scenario 1 | ACR-scenario 2 | European | |
---|---|---|---|---|
a. Immediate workup PET, biopsy, follow-up CT | ||||
Solid NCN, largest | ≥ 15.0 mm | ≥ 8 mm | ≥ 15 mm | ≥ 10 mm |
Part-solid NCN, largest | Solid component ≥ 15.0 mm | Solid component ≥ 8 mm | Solid component ≥ 8 mm | None |
b. 3-month LDCT | ||||
Solid NCN, largest | ≥ 6.0 mm but < 15.0 mm | – | ≥ 8 mm but < 15 mm | ≥ 5 mm but < 10 mm |
Part-solid NCN, largest | Solid component of NCN ≥ 6.0 mm but < 15.0 mm | Entire size of NCN ≥ 6 mm with solid component ≥ 6 mm but < 8 mm | Entire size of NCN ≥ 6 mm with solid component ≥ 6 mm but < 8 mm | Entire size of NCN ≥ 5 mm |
Nonsolid NCN, largesta | ≥ 5 mm | |||
c. 6-month LDCT | ||||
Solid NCN, largest | None | ≥ 6 to < 8 mm | ≥ 6 to < 8 mm | None |
Part-solid NCN, largest | None | Entire size of NCN ≥ 6 mm with solid component < 6 mm | Entire size of NCN ≥ 6 mm with solid component < 6 mm | None |
Nonsolid NCN, largestb | ≥ 20 mm | ≥ 20 mm |