Abstract
Purpose
Clinical applicability of the appropriate use criteria for SPECT myocardial perfusion imaging has not yet been evaluated in Italy. We investigated the applicability of the Appropriate Use Criteria (AUC) in Italy.
Methods
The indications for testing were prospectively recorded in three different nuclear cardiology laboratories: a general hospital, an academic hospital, and a tertiary centre. Indications were categorized as appropriate, uncertain or inappropriate according to the 2009 AUC; the specialty of the ordering physician was also noted. SPECT results were classified as: normal, probably normal, uncertain, probably abnormal, abnormal. The presence and severity of ischaemia were also noted.
Results
Over a 9-month period, 2,134 patients (age 67 ± 10 years, 68 % men) were evaluated (62 % exercise stress test). On average, there were 700 (84 %) appropriate, 73 (7 %) inappropriate and 93 (9 %) uncertain tests. The rates for the appropriateness of indications were comparable in men and women (84 % and 83 %, not significant). As expected, the rate of nonnormal studies was higher (58 %) for appropriate than for inappropriate (33 %) indications. Appropriateness was lower in the tertiary centre (74 %), and uncertain (16 %) and inappropriate (10 %) indications were more common; this was related to the higher rate of outpatients scheduled by nonhospital cardiologists (37 %). The most common indications associated with inappropriate testing were: chest pain, low likelihood of coronary artery disease, interpretable ECG and able to exercise (29 %), and asymptomatic <2 years after percutaneous coronary intervention (24 %).
Conclusion
In this preliminary evaluation of the AUC in Italy, the majority of studies were classified as appropriate, but a consistent proportion of scheduled SPECT studies, particularly by nonhospital cardiologists, were still categorized as uncertain or inappropriate. Educational approaches should be implemented to reduce the rate of less appropriate examinations. However, a substantial proportion (33 %) of inappropriate studies were classified as nonnormal, with 26 % of these patients having ischaemia.
Similar content being viewed by others
References
Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 Appropriate Use Criteria for Cardiac Radionuclide Imaging. J Am Coll Cardiol. 2009;53:2201–29.
Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol. 2008;51:1283–9.
Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol. 2010;55:156–62.
Gibbons RJ, Askew JW, Hodge D, Kaping B, Carryer DJ, Miller T. Appropriate use criteria for stress single-photon emission computed tomography sestamibi studies: a quality improvement project. Circulation. 2011;123:499–503.
Gholamrezanezhad A, Shirafkan A, Mirpour S, Rayatnavaz M, Alborzi A, Mogharrabi M, et al. Appropriateness of referrals for single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) in a developing community: a comparison between 2005 and 2009 versions of ACCF/ASNC appropriateness criteria. J Nucl Cardiol. 2011;18:1044–52.
Moralidis E, Papadimitriou N, Stathaki M, Xourgia X, Spyridonidis T, Fotopoulos A, et al. A multicenter evaluation of the appropriate use of single-photon emission tomography myocardial perfusion imaging in Greece. J Nucl Cardiol. 2013;20:275–83.
Abidov A, Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Kang X, et al. Are shades of gray prognostically useful in reporting myocardial perfusion SPECT? Circ Cardiovasc Imaging. 2009;2:290–8.
Berman DS, Germano G. Interpretation and reporting of gated myocardial perfusion SPECT. In: Germano G, Berman DS, editors. Clinical gated cardiac SPECT. 2nd ed. Oxford: Blackwell; 2006. p. 139–71.
Mehta R, Ward RP, Chandra S, Agarwal R, Williams KA. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging. J Nucl Cardiol. 2008;15:337–44.
Druz RS, Phillips LM, Sharifova G. Clinical evaluation of the appropriateness use criteria for single-photon emission-computed tomography: differences by patient population, physician specialty, and patient outcomes. ISRN Cardiol. 2011;2011:798318. doi:10.5402/2011/798318
Doukky R, Hayes K, Frogge N, Balakrishnan G, Dontaraju VS, Rangel MO, et al. Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging. Circulation. 2013;128:1634–43.
Conflicts of interest
None.
Author information
Authors and Affiliations
Consortia
Corresponding author
Rights and permissions
About this article
Cite this article
Medolago, G., Marcassa, C., Alkraisheh, A. et al. Applicability of the appropriate use criteria for SPECT myocardial perfusion imaging in Italy: preliminary results. Eur J Nucl Med Mol Imaging 41, 1695–1700 (2014). https://doi.org/10.1007/s00259-014-2743-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00259-014-2743-5