Abstract

This paper presents a method to find a reliable health index (HI) for oil-immersed transformers using reduced number of tests. The method depends on using the most important tests that are directly related to the transformer health. Field data for 90 working transformers were used to validate and test the proposed method. A linear relationship between the transformer HI and all available tests is proposed. The weights of the transformer tests are modeled exponentially according to the importance of each test. Subsequently, the HI is calculated using the three most important tests and the two most important tests. The results were compared with the results of existing research that uses a larger number of tests. The comparison shows that the proposed method gives acceptable results compared to other techniques that use a larger number of tests. As a result, the HI can be evaluated at lower cost, and a transformer health condition can be better monitored due to the ability to repeat HI evaluation at closer intervals.

Keywords

Asset management End of life Health condition Transformers 

Notes

References

  1. 1.
    Wang M, Vandermaar AJ, Srivastava KD (2002) Review of condition assessment of power transformers in service. IEEE Electr Insul Mag 18:12–25CrossRefGoogle Scholar
  2. 2.
    Abu-Elanien AEB, Salama MMA (2010) Asset management techniques for transformers. Electr Power Syst Res 80:456–464CrossRefGoogle Scholar
  3. 3.
    Abu-Elanien AEB, Salama MMA, Bartnikas R (2011) A techno-economic method for replacing transformers. IEEE Trans Power Deliv 26:817–829CrossRefGoogle Scholar
  4. 4.
    Abu-Elanien AEB, Salama MMA, Ibrahim M (2012) Calculation of a health index for oil-immersed transformers rated under 69 kV using fuzzy logic. IEEE Trans Power Deliv 27:2029–2036CrossRefGoogle Scholar
  5. 5.
    Jahromi A, Piercy R, Cress S, Service J, Fan W (2009) An approach to power transformer asset management using health index. IEEE Electr Insul Mag 25:20–34CrossRefGoogle Scholar
  6. 6.
    Khuntia SR, Rueda JL, Bouwman S, van der Meijden MAMM (2016) A literature survey on asset management in electrical power [transmission and distribution] system. Int Trans Electr Energy Syst 26:2123–2133CrossRefGoogle Scholar
  7. 7.
    Dominelli N (2004) Equipment health rating of power transformers. In: Conference record of the 2004 IEEE international symposium on electrical insulation, 2004, Indianapolis, IN, USA, pp 163–168Google Scholar
  8. 8.
    Naderian A, Cress S, Piercy R, Wang F, Service J (2008) An approach to determine the health index of power transformers. In: Conference record of the 2008 IEEE international symposium on electrical insulation, Vancouver, BC, Canada, pp 192–196Google Scholar
  9. 9.
    Proskurina NA, Iin MM, Davankov VA, Sychev KS, Kostikov SY (2007) A combination of solid-phase extraction on hypercrosslinked polystyrene with HPLC determination of furan derivatives in transformer oils. Russ J Phys Chem A 81:424–427CrossRefGoogle Scholar
  10. 10.
    Arvind D, Khushdeep S, Deepak K (2008) Condition monitoring of power transformer: a review. In: 2008 IEEE/PES transmission and distribution conference and exposition, Caracas, Venezuela, pp 1–6Google Scholar
  11. 11.
    Yang L, Liao R, Sun C, Sun H (2010) Influence of natural ester on thermal aging characteristics of oil–paper in power transformers. Eur Trans Electr Power 20:1223–1236CrossRefGoogle Scholar
  12. 12.
    Young J, Ma L, Wu L, Tang J, Huo L (2010) A new method to determine condition index for equipment condition assessment. In: 2010 prognostics and system health management conference, pp 1–6Google Scholar
  13. 13.
    Miletic S (2009) Asset condition assessment by health index benchmarking. In: CIRED 2009—20th international conference and exhibition on electricity distribution—part 1, pp 1–4Google Scholar
  14. 14.
    Tee S, Liu Q, Wang Z (2017) Insulation condition ranking of transformers through principal component analysis and analytic hierarchy process. IET Gener Transm Distrib 11(1):110–117CrossRefGoogle Scholar
  15. 15.
    Zeinoddini-Meymand H, Vahidi B (2016) Techno-economical lifetime assessment of power transformers rated over 50 MVA using artificial intelligence models. IET Gener Transm Distrib 10(15):3885–3892CrossRefGoogle Scholar
  16. 16.
    Ahmed M, Elkhatib M, Salama M, Shaban KB (2015) Transformer health index estimation using orthogonal wavelet network. In: 2015 IEEE electrical power and energy conference (EPEC), London, ON, Canada, pp 120–124Google Scholar
  17. 17.
    Abu-Elanien AEB, Salama MMA, Ibrahim M (2011) Determination of transformer health condition using artificial neural networks. In: 2011 international symposium on innovations in intelligent systems and applications, Istanbul, Turkey, pp 1–5Google Scholar
  18. 18.
    Zeinoddini-Meymand H, Vahidi B (2016) Health index calculation for power transformers using technical and economical parameters. IET Sci Meas Technol 10(7):823–830CrossRefGoogle Scholar
  19. 19.
    Cui Y, Ma H, Saha T (2015) Pattern recognition techniques for power transformer insulation diagnosis—a comparative study part 1: framework, literature, and illustration. Int Trans Electr Energy Syst 25:2247–2259CrossRefGoogle Scholar
  20. 20.
    Islam MM, Lee G, Hettiwatte SN (2017) Application of a general regression neural network for health index calculation of power transformers. Int J Electr Power Energy Syst 93:308–315CrossRefGoogle Scholar
  21. 21.
    Fernández FO, Ortiz A, Delgado F, Fernández I, Santisteban A, Cavallini A (2017) Transformer health indices calculation considering hot-spot temperature and load index. IEEE Electr Insul Mag 33:35–43CrossRefGoogle Scholar
  22. 22.
    IEEE guide for acceptance and maintenance of insulating oil in equipment (2006) IEEE Std C57.106-2006 (Revision of IEEE Std C57.106-2002), pp 1–36Google Scholar
  23. 23.
    Wahab MAA, Hamada MM, Zeitoun AG, Ismail G (1999) Novel modeling for the prediction of aged transformer oil characteristics. Electr Power Syst Res 51:61–70CrossRefGoogle Scholar
  24. 24.
    Lundgaard LE, Hansen W, Linhjell D, Painter TJ (2004) Aging of oil-impregnated paper in power transformers. IEEE Trans Power Deliv 19:230–239CrossRefGoogle Scholar
  25. 25.
    IEEE guide for the interpretation of gases generated in oil-immersed transformers (2009) IEEE Std C57.104-2008 (Revision of IEEE Std C57.104-1991), pp 1–36Google Scholar
  26. 26.
    Kachler AJ, Hohlein I (2005) Aging of cellulose at transformer service temperatures. Part 1: influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil. IEEE Electr Insul Mag 21:15–21CrossRefGoogle Scholar
  27. 27.
    Stebbins RD, Myers DS, Shkolnik AB (2003) Furanic compounds in dielectric liquid samples: review and update of diagnostic interpretation and estimation of insulation ageing. In: Proceedings of the 7th international conference on properties and applications of dielectric materials, Nagoya, Japan, Japan, vol 3, pp 921–926Google Scholar
  28. 28.
    Xiang Z, Ernst G, Volker W, Hossein B (2007) Estimation of the lifetime of the electrical components in distribution networks. IEEE Trans Power Deliv 22:515–522CrossRefGoogle Scholar
  29. 29.
    Emsley AM, Xiao X, Heywood RJ, Ali M (2000) Degradation of cellulosic insulation in power transformers. Part 3: effects of oxygen and water on ageing in oil. IEEE Proc Sci Meas Technol 147:115–119CrossRefGoogle Scholar
  30. 30.
    Azmi A, Jasni J, Azis N, Kadir MZAA (2017) Evolution of transformer health index in the form of mathematical equation. Renew Sustain Energy Rev 76:687–700CrossRefGoogle Scholar
  31. 31.
    Benhamed K, Mooman A, Younes A, Shaban K, El-Hag A (2018) Feature selection for effective health index diagnoses of power transformers. IEEE Trans Power Deliv 33:3223–3226CrossRefGoogle Scholar

Copyright information

© Springer-Verlag GmbH Germany, part of Springer Nature 2019

Authors and Affiliations

  1. 1.Electrical and Computer Engineering DepartmentDhofar UniversitySalalahOman
  2. 2.Electrical Engineering Department, Faculty of EngineeringAlexandria UniversityAlexandriaEgypt
  3. 3.Electrical and Computer Engineering DepartmentUniversity of WaterlooWaterlooCanada

Personalised recommendations