Abstract

The ordinary CUSUM chart is based on normality assumption. But in real-life phenomenon such as monitoring of lifetime variable, this assumption is not always valid. Hence, a variant of the CUSUM chart, the VCUSUM chart, has been constructed to monitor small shift in a process that is based on a Maxwell distribution. The performance of the chart has been checked by studying the run length properties and it was found to perform better for small shifts as compared to Shewhart type V chart for Maxwell parameter. Finally, a real-life application is presented to monitor the failure rate of a vertical boring machine.

Keywords

Maxwell distribution Gamma distribution Exponential family of distribution CUSUM control chart Run length distribution 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Notes

Acknowledgements

Dr. Omar and Dr. Riaz would like to acknowledge research facilities made available to them by King Fahd University of Petroleum and Minerals, Saudi Arabia.

Funding

Mr. Hossain would like thank Bangabandhu Sheikh Mujibur Rahman Science and Technology University for research support through grant no. 5921.

References

  1. 1.
    Montgomery DC, Introduction to Statistical Quality Control, 7th ed. John Wiley & Sons Inc., 2009Google Scholar
  2. 2.
    Page ES (1954) Continuous inspection schemes. Biometrika 41(1/2):100–114MathSciNetCrossRefGoogle Scholar
  3. 3.
    Roberts SW (1959) Control chart tests based on geometric moving averages. Technometrics 1(3):239–250CrossRefGoogle Scholar
  4. 4.
    Acosta-Mejia C a, Pignatiello JJ, Venkateshwara Rao B (1999) A comparison of control charting procedures for monitoring process dispersion. IIE Trans 31(6):569–579Google Scholar
  5. 5.
    Ryu J-H, Wan H, Kim S (2010) Optimal design of a CUSUM chart for a mean shift of unknown shift. J Qual Technol 42(3):311–326CrossRefGoogle Scholar
  6. 6.
    Tran KP, Castagliola P, and Celano G (2016) “Monitoring the ratio of population means of a bivariate normal distribution using CUSUM type control charts,”. Stat Pap, pp. 1–27Google Scholar
  7. 7.
    Ghobadi S, Noghondarian K, Noorossana R, Mirhosseini SMS (2015) Developing a fuzzy multivariate CUSUM control chart to monitor multinomial linguistic quality characteristics. Int J Adv Manuf Technol 79(9–12):1893–1903CrossRefGoogle Scholar
  8. 8.
    Sanusi RA, Riaz M, Abbas N, Abujiya MR (2016) Using FIR to improve CUSUM charts for monitoring process dispersion. Qual Reliab Eng Int 33(5):1045–1056CrossRefGoogle Scholar
  9. 9.
    Goel AL, Wu SM (1971) Determination of a.R.L. and a contour nomogram for cusum charts to control normal mean. Technometrics 13(2):221–230zbMATHGoogle Scholar
  10. 10.
    Chiu WK (1974) Economic design of cusum charts for controlling normal means. Journal of Appl Stat 23(3. JSTOR):420–433CrossRefGoogle Scholar
  11. 11.
    Lucas JM, Crosier RB (2000) Fast initial response give your CUSUM quality-control head start. Technometrics 42(1):102–107CrossRefGoogle Scholar
  12. 12.
    Ou Y, Wu Z, Lee KM, Wu K (2013) An adaptive CUSUM chart with single sample size for monitoring process mean and variance. Qual Reliab Eng Int 29(7):1027–1039CrossRefGoogle Scholar
  13. 13.
    Sanusi RA, Abbas N, Riaz M (2017) On efficient CUSUM-type location control charts using auxiliary information. Quality Technology and Quantitative Management 15(1):87–105CrossRefGoogle Scholar
  14. 14.
    Sanusi RA, Abujiya MR, Riaz M, Abbas N (2017) Combined Shewhart CUSUM charts using auxiliary variable. Comput Ind Eng 105:329–337CrossRefGoogle Scholar
  15. 15.
    Lucas JM, Crosier RB (1982) Robust Cusum: a robustness study for Cusum quality control schemes. Communications in Statistics - Theory and Methods 11(23):2669–2687MathSciNetCrossRefGoogle Scholar
  16. 16.
    Zhang S, Wu Z (2007) A CUSUM scheme with variable sample sizes for monitoring process shifts. Int J Adv Manuf Technol 33(9–10):977–987CrossRefGoogle Scholar
  17. 17.
    Jiao JR, Helo PT (2008) Optimization design of a CUSUM control chart based on taguchi’s loss function. Int J Adv Manuf Technol 35(11–12):1234–1243CrossRefGoogle Scholar
  18. 18.
    Abbasi SA, Miller A (2012) On proper choice of variability control chart for normal and non-normal processes. Qual Reliab Eng Int 28(3):279–296CrossRefGoogle Scholar
  19. 19.
    Khaliq QUA, Riaz M, Ahmad S (2016) On designing a new Tukey-EWMA control chart for process monitoring. Int J Adv Manuf Technol 82:1–4, pp. 1–23CrossRefGoogle Scholar
  20. 20.
    Vardeman S, ou Ray D (1985) Average run lengths for cusum schemes when observations are exponentially distributed. Technometrics 27(2):145–150MathSciNetCrossRefGoogle Scholar
  21. 21.
    Celano G, Castagliola P, Trovato E (2012) The economic performance of a CUSUM t control chart for monitoring short production runs. Quality Technology & Quantitative Management 9(4):329–354CrossRefGoogle Scholar
  22. 22.
    Huang W, Shu L, Jiang W, Tsui KL (2013) Evaluation of run-length distribution for CUSUM charts under gamma distributions. IIE Transactions (Institute of Industrial Engineers) 45(9):981–994Google Scholar
  23. 23.
    Hossain MP, Omar MH, Riaz M (2017) New V control chart for the Maxwell distribution. J Stat Comput Simul 87(3):594–606MathSciNetCrossRefGoogle Scholar
  24. 24.
    Morse PM (1962) Thermal physics. W. A. Benjamin, Inc., New YorkzbMATHGoogle Scholar
  25. 25.
    Kazmi SMA, Aslam M, Ali S (2011) A note on the maximum likelihood estimators for the mixture of Maxwell distributions using type-I censored scheme. The Open Statistics and Probability Journal 3:31–35MathSciNetCrossRefGoogle Scholar
  26. 26.
    Krishna H, Malik M (2012) Reliability estimation in Maxwell distribution with prograsively type-II censored data. J Stat Comput Simul 82(4):623–641MathSciNetCrossRefGoogle Scholar
  27. 27.
    Tomer SK, Panwar MS (2015) Estimation procedures for Maxwell distribution under type-I progressive hybrid censoring scheme. J Stat Comput Simul 85(2):339–356MathSciNetCrossRefGoogle Scholar
  28. 28.
    Weisstein EW, “Maxwell Distribution,”. Wolfram mathworld, 2017. [Online]. Available: http://mathworld.wolfram.com/MaxwellDistribution.html. [Accessed: 31-Dec-2017]
  29. 29.
    Hawkins DM and Olwell DH (1998) Cumulative sum charts and charting for quality improvementCrossRefGoogle Scholar
  30. 30.
    R Core Team, “R: a language and environment for statistical computing. R Foundation for statistical computing, Vienna, Austria. 2015. URL h ttp,” http://www.R-project.org, 2016
  31. 31.
    “Boring machine | Encyclopaedia Britannica.”Google Scholar
  32. 32.
    Majumdar SK (1993) An optimum maintenance strategy for a vertical boring machine system. Operational Research Society of India 30:344–365zbMATHGoogle Scholar

Copyright information

© Springer-Verlag London Ltd., part of Springer Nature 2018

Authors and Affiliations

  1. 1.Department of StatisticsBangabandhu Sheikh Mujibur Rahman Science and Technology UniversityGopalganjBangladesh
  2. 2.School of Data ScienceCity University of Hong KongKowloon TongHong Kong
  3. 3.Department of Systems Engineering and Engineering ManagementCity University of Hong KongKowloon TongHong Kong
  4. 4.Department of Mathematics and StatisticsKing Fahd University of Petroleum and MineralsDhahranSaudi Arabia

Personalised recommendations