Poor high frequency results following total stapedectomy—Theoretical considerations

Abstract

Theoretical considerations behind the lack of satisfactory improvement at high frequency of 4000 Hz, 6000 Hz and 8000 Hz are discussed. A small fenestra and a correct fitting prosthesis seems to be giving better high frequency results.

This is a preview of subscription content, log in to check access.

References

  1. 1.

    Anson and Donaldson (1967):Surgical Anatomy of the temporal bone and ear, W.B. Saunders and Company.

  2. 2.

    Bluestone C.D. (1962): Polythene stainless steel core in middle ear surgery,Archives of Otolaryngology,76: 303.

  3. 3.

    Bull T.R. (1966): Case report-Noise trauma to stapedectomised ear,Journal of Laryngology and Otology,81: 631.

  4. 4.

    Conan, W.B., Doyle A.B. (1968): Stapedectomy and stapedial reflex.Journal of Laryngology and Otology,82: 907.

  5. 5.

    Desmond, A.F. (1969): Experimental prosthesis in Stapes sursery.Indian Journal of Otolaryngology,21: 28.

  6. 6.

    Duncan R.B. (1963): Cartilage technique and restoration of stapedius muscle.Archives of Otolaryngology,78: 39.

  7. 7.

    Ehmke, O. (1964): Platinum Stapedial prosthesis in middle ear surgery.Archives of Otolaryngology,79: 54.

  8. 8.

    Farrior, J.B., (1962): Stapedectomy and Tympanoplasty.Archives of Otolaryngology,76: 40.

  9. 9.

    Ferris K. (1967): A further study of the temporary effect of Industrial noise on the hearing of Stapedectomised esr at 4000 cps.Journal of Laryngology and Otology,81: 613.

  10. 10.

    Fletcher, J.L., King, W.D. (1963): Susceptibijity of Stapedectomised patients to noise induced temporary threshold shifts.Annals of Otology Rhinology and Laryngology,72: 900

  11. 11.

    Glanninger J. (1962): Problems of sparing incudostapedial joint in operation of Otosclerosis,J. Laryngol Rhinol. Otol. 41: 762.

  12. 12.

    Groves J. (1979): Physiology of hearing, Scott Browns Disease of the Ear, Nose and Throat Vol I.Butterworths 4th Edition 95.

  13. 13.

    Guilford F.R. (1961): Personal experiences with Shea oval window Vein graft techniqueLaryngoscope 71: 484.

  14. 14.

    Guilford F.R. (1963): Panel on techniques and results of stapes surgeryArchives of Otolaryngology 78: 546.

  15. 15.

    Hough J.V.D. (1969): Long term results in partial stapedectomy.Archive/ of Otolaryngology 89: 414.

  16. 16.

    Kos, CM. (1969): Vein Plug stapedectomy—Results.Archives of Otolaryngology 89: 422.

  17. 17.

    Lawrence, M. (1960): A coustic effects of middle ear substitution Trans.Amer Acad. Opthal Otol 64: 235.

  18. 18.

    Lawrence, M. (1960): Mechanism of air conduction.Archives of Otolaryngology 78: 284.

  19. 19.

    McGee T.M. (1965): The stainless steel piston.Archives of Otolaryngology 81: 34.

  20. 20.

    McGee, T.M. (1969): Fat and wire stapedectomy surgery.Archives of Otolaryngology 89: 423.

  21. 21.

    Mercandino E.C., Tarasido I.C. (1961): Artificial stapes.Archives of Otolaryngology 73: 635

  22. 22.

    Meurman O.H. Woolf H. (1960): Hightone loss in OtosclerosisActa Otolaryngologica (Stockholm)51: 299.

  23. 23.

    Miller, M.H., Rendait, J., Kolman, M. (1961): BC chanses following audiosurgery.Archives of Otolaryngology 74: 213.

  24. 24.

    Morrison A.W. (1979): Diseases of Otic capsule—Otosclerosis, Scott Browns Diseases of the Ear, Nose and Throat Vol. II.Butterworths 4th Edition 451.

  25. 25.

    Robinson M. (1965): A four years study of stainless steel stapes.Archives of Otolaryngology 82: 217.

  26. 26.

    Rosen, S. & Siegel K. (1969): Rosen mobilisation and stapedectomy.Archives of Otolaryngology 89: 425.

  27. 27.

    Ruedi L. (1969): Long term results in Stapedectomy.Archives of Otolaryngology 89: 429.

  28. 28.

    Ruggles R.L. (1962): Experiences with interposition during partial stapedectomy.Laryngoscope 72: 813.

  29. 29.

    Sataloff J. Menduke H., Hughes A. (1962): Temporary threshold shifts in normal and abnormal ears.Archives of Otolaryngology 76: 52.

  30. 30.

    Shambaugh G. (Jr.) (1963): Summary — Unsolved problems — Panel stapes surgery.Archives of Otolaryngology 78: 627.

  31. 31.

    Shea J.J., Sambria F., Smythe G.D.L. (1962): Teflon piston for Otosclerosis.Archives of Otolaryngology 76: 516.

  32. 32.

    Shea J.J. (Jr.) (1960): Fenestration of the oval window,Trans. Amer. Acad. Ophthol Otolaryngol 64: 611.

  33. 33.

    Siirala U. (1969): A stainless steel plate prosthesis for stapedectomy.Archives of Otolaryngology 90: 225

  34. 34.

    Wever E.G., Lawrence M. (1950): Transmission properties of the stapesAnnals of Otology, Rhinology and Laryngology 59: 322.

  35. 35.

    Zalin, H. (1964): A consideration of certain factors that may contribute to failure in stapedectomy operations.Journal of Laryngology and Otology 78: 1030.

Download references

Author information

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Raman, R. Poor high frequency results following total stapedectomy—Theoretical considerations. Indian J Otolaryngol 35, 9–11 (1983). https://doi.org/10.1007/BF02992304

Download citation

Keywords

  • Otosclerosis
  • Oval Window
  • Noise Induce Hearing Loss
  • Temporary Threshold Shift
  • Satisfactory Improvement