Practical Failure Analysis

, Volume 2, Issue 3, pp 45–49 | Cite as

SO2 heat exchanger failure

  • W. Reitz
Peer Reviewed Articles
  • 114 Downloads

Abstract

Critical heat exchanger components are usually manufactured from durable steels, such as stainless steel, which exhibit good strength and corrosion resistance. Failure of a heat exchanger occurred due to specification of a plain carbon steel that did not survive service in the SO2 vapor environment. However, failure analysis showed that cavitation erosion was the responsible failure mechanism, not corrosion as might be expected.

Keywords

heat exchanger cavitation erosion plain carbon steel 316 stainless steel microstructure corrosion SO2 hardness 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    D.A. Jones:Principles and Prevention of Corrosion, MacMillan Publishing Co., New York, 1992, p. 515.Google Scholar
  2. 2.
    D.N. French:Metallurgical Failures in Fossil Fired Boilers, John Wiley & Sons, Inc., New York, 1993, p. 378.Google Scholar
  3. 3.
    Anon.: inASM Handbook, vol. 13,Corrosion, 9th ed., ASM International, Metals Park, OH, 1987, p. 333.Google Scholar
  4. 4.
    Anon.: inCatalog Handbook of Fine Chemicals, Aldrich Chemical Co., Inc., Milwaukee, WI, 1991, p. 1188.Google Scholar
  5. 5.
    Anon.: inASM Handbook, vol. 13,Corrosion, 9th ed., ASM International, Metals Park, OH, 1987, p. 142.Google Scholar