This study presents the one-year experience with a new copper-releasing intrauterine contraceptive device, the Fincoid IUD. Between November 1984 and August 1985, 650 Fincoid devices were inserted in parous women to test the efficacy and clinical performance of the devices. After one year, 16 pregnancies had occurred (2.8 net cumulative rate); 26 devices had been partially or totally expelled (4.4); 27 devices had been removed for bleeding and/or pain (4.7); and 16 devices had been removed for other medical reasons (2.8). The continuation rate at the end of the first year was 84.3, indicating a good clinical performance.

Résumé

Cette étude présente l'expérience d'une année sur l'utilisation d'un nouveau dispositif contraceptif intra-utérin libérant du cuivre appelé Fincoid UDI. Entre novembre 1984 et août 1985, 650 de ces dispositifs ont été insérés chez des femmes qui avaient déjà eu des enfants, l'objectif étant d'en tester l'utilité et la performance clinique. Un an après, on a constaté 16 grossesses (taux cumulatif net de 2,8), l'expulsion partielle ou totale du dispositif dans 26 cas (4,4), le retrait de 27 dispositifs pour cause de saignement et/ou de douleurs (4,7) et le retrait de 16 autres pour d'autres raisons médicales (2,8). Au terme de la première année, le taux de poursuite atteignait 84,3, indiquant une performance clinique satisfaisante.

Resumen

Este estudio presenta la experiencia de un año con Fincoid, un nuevo dispositivo intrauterino liberador de cobre. Entre noviembre de 1984 y agosto de 1985, 650 dispositivos Fincoid fueron insertados en mujeres paras para probar la eficacia y la actuacion clínica de los dispositivos. Al cabo de un año ocurrieron 16 embarazos (2,8 tasa neta acumulativa); 26 dispositivos fueron expulsados total o parcialmente (4,4); 27 dispositivos fueron removidos por sangrado y/o dolor (4,7) y 16 dispositivos fueron removidos por otras razones médicas (2,8). La tasa de continuidad al cabo del primer año fue de 84, 3 lo que indica un buen resultado clínico.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. HirvonenE., KaivolaS. and TimonenH. (1982). Fincoid—a new copper IUD. A preliminary report.Contracept. Deliv. Syst.,3, 83–89

    PubMed  Google Scholar 

  2. KaivolaS. and HirvonenE. (1984). Influence of age on the clinical performance of IUD in nulliparous and parous women: an analysis of 1144 insertions.Contracept. Deliv. Syst.,5, 7–10

    PubMed  Google Scholar 

  3. KaivolaS. (1986). Tailoring of IUD (Fincoid-350) insertions-experience with Hasson's Wing Sound Cavimeter.Adv. Contracept.,2, 177–184

    PubMed  Google Scholar 

  4. TietzeC. and LewitS. (1973). Recommended procedures for the statistical evaluation of intraterine contraception.Stud. Fam. Plann.,4, 35–42

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Batár, I. One-year results with the Fincoid IUD—A Hungarian experience with the short model. Adv Contracept 4, 137–142 (1988). https://doi.org/10.1007/BF01849515

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01849515

Keywords

Navigation