Advertisement

Springer Nature is making SARS-CoV-2 and COVID-19 research free. View research | View latest news | Sign up for updates

Quantitative HPLC-Bestimmung von Sultiam (Ospolot) im Plasma

Quantitative HPLC determination of sulthiame (ospolot) in human plasma

Summary

A high-performance liquid-chromatographic method is described for the determination of sulthiame in human plasma. The single-step extraction is performed by acetonitrile. The advantage of this extraction is: the acetonitrile extract is suitable for direct injection into the HPLC system without a further purification step.

A methyl derivative of sulthiame was synthesized for use as an internal standard.

The sulthiame was determined down to about 1 μg/ml in a 0.5 ml plasma sample. The relative standard deviation at the 1 μg/ml level of sulthiame was 6% (n=5).

Zusammenfassung

Es wird ein hochleistungsflüssigkeitschromatographisches Verfahren zur Bestimmung von Sultiam im Plasma beschrieben. Die Extraktion erfolgt mit Acetonitril ohne Vorbehandlung des Plasmas. Der Vorteil dieser Einmalextraktion liegt darin, daß sich bei der Aufarbeitung von Plasma der abgetrennte Gesamtüberstand zum direkten Einspritzen in das HPLC-System ohne einen weiteren Reinigungsschritt eignet.

Synthetisiertes Sultiam-Methylderivat wird als interner Standard verwendet.

Die Nachweisgrenze bei einem Probevolumen von 0,5 ml Plasma liegt bei 1 μg/ml und hat in dieser Konzentration eine relative Standardabweichung von 6% (n=5).

This is a preview of subscription content, log in to check access.

Literatur

  1. 1.

    Buchtal F, Svenmark O, Schiller PJ (1960) Arch Neurol 2:624–630

  2. 2.

    Schmidt D (1977) Nervenarzt 48:183–196

  3. 3.

    Livingston S, Berman W (1972) New Engl J Med 287:934

  4. 4.

    Laboratory Management, July 1978, Syva Co, Palo Alto, California

  5. 5.

    Deisenhammer E, Sommer R (1972) Wiener Klin Wochenschr 17:571–578

  6. 6.

    Hackett LP, Dusci LJ (1976) Clin Chim Acta 66:443–447

  7. 7.

    Simons KJ, Levy RH (1972) J Pharm Sci 61:1252–1256

  8. 8.

    Klotz U (1981) J Chromatogr 222:501–506

  9. 9.

    Olesen OV (1968) Acta Pharm Toxicol 26:22–28

  10. 10.

    Egli M, Hess R, Wad N (1978) Nervenarzt 49:402–404

Download references

Author information

Correspondence to F. Susanto.

Additional information

Der Fa. Bayer AG, Leverkusen, danken wir für die Überlassung der Sultiam-Reinsubstanz. Ferner danken wir Fr. Neumann für ihre technische Mitarbeit.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Susanto, F., Reinauer, H. Quantitative HPLC-Bestimmung von Sultiam (Ospolot) im Plasma. Z. Anal. Chem. 318, 531–532 (1984). https://doi.org/10.1007/BF00678757

Download citation