Summary
The pneumotonograph was evaluated for its capability to record and measure intraocular pressure through soft contact lenses. In a series of patients with chronic corneal diseases treated with soft contact lenses, good pressure and intraocular pulsations were recorded both with and without the soft lenses. Areas of scarred cornea give incorrect values, whereas areas of corneal edema give values similar to those obtained in the presence of a soft lens and are believed to reflect accurate and reliable pressure readings. In normal eyes, it has been found that the presence of a plain soft lens does not modify the accuracy of pressure measurement. High values do occur, however, when the refraction of the lens exceeds eight diopters.
Zusammenfassung
Es wurde in vorliegender Studie die Möglichkeit überprüft, mit dem Pneumotonographen auf weichen Kontaktlinsen den intraokularen Druck zu messen. Bei einer Reihe von Patienten mit chronischen Hornhauterkrankungen, welche mit weichen Kontaktlinsen behandelt wurden, wurde der Augeninnendruck sowohl auf der Kontaktlinse wie auf der erkrankten Hornhaut registriert. Beide Augendruckkurven gaben hinreichend brauchbare und zuverlässige Resultate. Augendruckmessungen auf weichen Kontaktlinsen verschiedener Refraktion bei gesunden Augen zeigten, daß die ermittelten Druckwerte zu hoch sind, wenn die Refraktion der Linsen acht Dioptrien übersteigt.
Similar content being viewed by others
Literatur
Brethfeld, V.: Die Behandlung von Hornhauterkrankungen mit weichen hydrophilen Kontaktlinsen. Med. Welt (Stuttg.) 26, 762–764 (1975)
Havener, W. H.: Ocular pharmacology, 3. Aufl. St. Louis: C. V. Mosby Comp. 1974
Kaufmann, H. E.: Pressure measurement: Which tonometer? Invest. Ophthal. 11, 80–58 (1972)
Kaufmann, H. E., Gasset, A. R., Wood, T. O., Ellison, E. D.: The medical uses of soft contact lenses. Trans. Amer. Acad. Ophthal. Otolaryng. 75, 361–373 (1971)
Krakau, C. E. T., Wilke, K.: On repeated tonometry. Acta ophthal. (Kbh.) 49, 611–614 (1971)
Quigley, H. A., Langham, M. E.: Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer. Amer. J. Ophthal. 80, 266–273 (1975)
Tierney, J. P., Rubin, M. L.: A clinical evaluation of the electronic applanation tonometer. Amer. J. Ophthal. 62, 263–269 (1966)
Walker, R. E., Litovitz, T. L.: An experimental and theoretical study of the pneumatic tonometer. Exp. Eye Res. 13, 14–23 (1972)
West, C. E., Capella, J. A., Kaufmann, H. E.: Measurement of intraocular pressure with a pneumatic applanation tonometer. Amer. J. Ophthal. 74, 505–509 (1972)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Krieglstein, G.K., Waller, W.K., Reimers, H. et al. Augeninnendruckmessung auf weichen Kontaktlinsen. Albrecht von Graefes Arch. Klin. Ophthalmol. 199, 223–229 (1976). https://doi.org/10.1007/BF00417291
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00417291