The external fixateur in the management of unstable colles' fracture

  • 37 Accesses

  • 22 Citations

Summary

Colles' fracture is frequently unstable with a high incidence of redisplacement, varying from 40–60% in various published series. Redisplacement following reduction can be avoided with a small external fixateur using two pins placed at right angles to each other both in the distal fragment and the radial shaft. This technique has been employed in twenty-two patients with secondary displacement of Colles' fracture and the end results evaluated by the McBridge points system was excellent or good in twenty-one of the twenty-two patients.

Résumé

Les fractures de l'extrémité inférieure du radius sont souvent instables, d'où un pourcentage important de déplacement itératif, variant, selon les séries publiées, de 40 à 60%. Ce redéplacement après réduction peut être évité grâce à l'utilisation d'un petit fixateur externe, dont deux fiches sont placées perpendiculairement l'une à l'autre dans le fragment distal et deux autres dans la diaphyse. Cette technique a été utilisée chez 22 blessés présentant un déplacement secondaire après réduction d'une fracture de Pouteau-Colles. Les résultats, évalués selon la cotation de Mc Bride, ont été bons ou excellents dans 21 cas sur 22.

This is a preview of subscription content, log in to check access.

References

  1. 1.

    Bacorn, R. W., Kurzke, F. J.: Colles' fracture: a study of two thousand cases. J. Bone Joint Surg. 35, 643–658 (1953)

  2. 2.

    Böhler, L.: Technik der Knochenbruchbehandlung. Wienna, Maudrich, 1937

  3. 3.

    Cartier, P., Tiesse, J., Pere, Ch.: Traitement des fractures comminutives du poignet par la méthode de traction bipolaire. Rev. Chir. Orthop. 61, 517–531 (1975)

  4. 4.

    Cole, J. M., Obletz, B. E.: Comminuted fractures of the distal end of the radius treated by skeletal transfixation in plaster cast. J. Bone Joint Surg. [Am.] 48, 931–945 (1966)

  5. 5.

    Cooney, W. P., Linscheid, R. L., Dobyns, J. H.: External pin fixation for unstable Colles' fractures. J. Bone Joint Surg. [Am]. 61, 840–845 (1979)

  6. 6.

    Dowling, J. J., Sawyer, B. Jr.: Comminuted Colles' fractures. Evaluation of a method of treatment. J. Bone Joint Surg. [Am.] 43, 657–668 (1961)

  7. 7.

    Fernandez, D. L., Albrecht, H. H., Sachs U.: Die Korrektureosteotomien am distalen Radius bei posttraumatischer Fehlstellung. Arch. Orthop. Unfallchir. 90, 199–205 (1974)

  8. 8.

    Frykmann, G.: Fracture of the distal radius including sequale shoulder-hand-finger syndrome. Acta Orthop. Scand., Suppl. 108 (1967)

  9. 9.

    Gartland, J. J. Jr., Werley C. W.: Evaluation of healed Colles' fractures. J. Bone Joint Surg. [Am.] 33, 895–907 (1951)

  10. 10.

    Heim, U.: Die gelenknahen Speichenbrüche des Erwachsenen. Unfallheilkunde 82, 15–22 (1979)

  11. 11.

    Koch, E.: Die handgelenknahen Speichenbrüche im Erwachsenenalter. Orthopädie 4, 14–18 (1975)

  12. 12.

    Lanz, U., Kron, W.: Neue Technik zur Korrektur in Fehlstellung verheilter distaler Radiusfrakturen. Handchirurgie 8, 203–206 (1976)

  13. 13.

    McBride, E. D.: Disability evaluation. Principles of treatment of compensable injuries. J. B. Lippincott Co., Philadelphia, 1948

  14. 14.

    Müller-Färber, J., Griebel, W.: Der sekundäre Korrektureingriff am distalen Radius bei posttraumatischer Fehlstellung. Unfallheilkunde 82, 23–28 (1979)

  15. 15.

    Rauis, A., Ledoux, A., Thiebaut, A., Ghinst, M.: Bipolar fixation of fractures of the distal end of the radius. Clin. Orthop. (SICOT) 3, 89–96 (1979)

  16. 16.

    Roth, B., Müller, J., Lusser, G., Bartone, C., Bachmann, B.: Erfahrungen mit perkutanen Spickdrahtosteosynthese. Helv. Chir. Acta 44, 815–821 (1977)

  17. 17.

    Stockmann, U., Birnbaum, D., Büssig, E. W., Hepp, W., Lippe, B., Zuschneid, W.: Die Problematik der distalen Radiusfraktur aus der Sicht des Patienten. Unfallheilkunde 79, 71–74 (1976)

  18. 18.

    Willenegger, H., Guggenbühl, A.: Zur operativen Behandlung bestimmter Fälle von distalen Radiusfrakturen. Helv. Chir. Acta 26, 81–85, (1959)

Download references

Author information

Correspondence to M. Forgon.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Forgon, M., Mammel, E. The external fixateur in the management of unstable colles' fracture. International Orthopaedics 5, 9–14 (1981). https://doi.org/10.1007/BF00286093

Download citation

Key words

  • Wrist
  • Colles' fracture
  • External fixation