Delayed foreign-body reaction to silk sutures in pediatric neurosurgical patients

  • Eugene RossitchJr.
  • Dennis E. Bullard
  • W. Jerry Oakes
Original Papers

Abstract

Nonabsorbable silk sutures have been a frequently used foreign material in neurosurgery. In general, they are reliable and safe with minimal bio-incompatibility. Three pediatric neurosurgical patients came to clinical attention, however, because of delayed foreign-body reactions to silk sutures. The delayed atypical presentation of these patients delayed appropriate diagnosis and therapy. In two patients, the reaction presented as a delayed inflammation 7 years following surgical suture placement. In the other patient, the reaction caused delayed recurrent shunt failures and surgical wound breakdown. These three cases are used to introduce a discussion of the delayed response of the host to foreign material and its pertinence to neurosurgery.

Key words

Foreign body reaction Silk sutures Neurosurgery 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Ammar A (1985) Tissue compatibility of different intracranial implant materials: in vivo and in vitro studies. Acta Neurochir (Wien) 72:45–59CrossRefGoogle Scholar
  2. 2.
    Culter EC, Dumphy JE (1941) The use of silk in infected wounds. N Engl J Med 224:101–106CrossRefGoogle Scholar
  3. 3.
    Halsted WS (1913) Ligature and suture material. Employment of fine silk in preference to catgut and the advantages of transfixion of tissue and vessels in control of hemorrhage. JAMA 60:1119–1126CrossRefGoogle Scholar
  4. 4.
    Postlethwait RW (1969) Tissue reaction to surgical sutures. In: Dumphy JE, Van Winkle W (eds) Repair and regeneration. McGraw-Hill, New York, pp 263–285Google Scholar
  5. 5.
    Postlethwait RW (1970) Long-term comparative study of nonabsorbable sutures. Ann Surg 171:892–897CrossRefGoogle Scholar
  6. 6.
    Postlethwait RW, Dillon MD, Reeves JW (1962) Experimental study of silk suture. Arch Surg 84:698–702CrossRefGoogle Scholar
  7. 7.
    Rossitch E, Friedman AH, Bullard DE (1985) Foreign body reaction to rubber Torkildsen catheters: a report of two cases. Neurosurgery 17:838–842CrossRefGoogle Scholar
  8. 8.
    Shambaugh P, Dunphy JE (1937) Postoperative wound infections and the use of silk: an experimental study. Surgery 1:379–385Google Scholar
  9. 9.
    Von Fraunhofer JA, Storey RS, Stone IK, Masterson BJ (1985) Tensile strength of suture materials. J Biomed Mater Res 19:595–600CrossRefGoogle Scholar

Copyright information

© Springer-Verlag 1987

Authors and Affiliations

  • Eugene RossitchJr.
    • 1
  • Dennis E. Bullard
    • 1
  • W. Jerry Oakes
    • 1
  1. 1.Department of Surgery, Division of NeurosurgeryDuke University Medical CenterDurhamUSA

Personalised recommendations