Skip to main content

Gas Chromatography of Fatty Acid Methyl Esters: Fast Analysis

  • Living reference work entry
  • First Online:
  • 347 Accesses

Faster elution time can be achieved using the latest generation of columns and GC. Reduction of analytical cost and increased laboratory productivity and sample throughput are some of the benefits obtained. Depending on the application, a classification can be very helpful when it comes to choose the appropriate instrumentation (Korytár et al. 2002; Van Deursen et al. 1999; Bicchi et al. 2004). Fast GC analysis refers to separation time that is achieved in the range of minutes and the average peak width between 1 and 3 s. Also defined was the analysis with separation performed in less than 10 min with columns with ID between 0.25 and 0.1 mm, length from 5 to 15 m, temperature programming rates of 20–60 °C/min, and peak widths in the range between 0.5 and 2 s. Very fast GC refers to separation time that is achieved in the range of seconds and the average peak width between 30 and 200 ms. Ultrafast GC refers to separation time that is achieved in the sub-second range and the average...

This is a preview of subscription content, log in via an institution.

References

  • Bicchi C, Brunelli C, Cordero C, Rubiolo P, Galli M, Sironi A. Direct resistively heated column gas chromatography (Ultrafast module-GC) for high-speed analysis of essential oils of differing complexities. J Chromatogr A. 2004;1024:195–207.

    Article  CAS  PubMed  Google Scholar 

  • Blumberg LM, Klee MS. Method translation and retention time locking in partition GC. Anal Chem. 1998;70:3828–39.

    Article  CAS  Google Scholar 

  • Cramers CA, Leclercp PA. Strategies for speed optimisation in gas chromatography: an overview. J Chromatogr A. 1999;842:3–13.

    Article  CAS  Google Scholar 

  • Dalluge J, Ou-Aissa R, Vrelus JJ, Brinkman UAT. Fast temperature programming in gas chromatography using resistive heating. J High Resolut Chromatogr. 1999;22:459–64.

    Article  CAS  Google Scholar 

  • Dyson N. Peak distortion, data sampling errors and the integrator in the measurement of very narrow chromatographic peaks. J Chromatogr A. 1999;842:321–40.

    Article  CAS  Google Scholar 

  • Frank D, Sandra P. Use of hydrogen as carrier gas in capillary GC. Am Lab. 1999.

    Google Scholar 

  • Guillemin CL, Gressin JC, Vermont J, Cirendini S. Rapid gas chromatographic analysis on Spherosil. J Chromatogr. 1973;84:21–36.

    Article  Google Scholar 

  • Halasz I, Gerlach HO. Micropacked columns. Anal Chem. 1966;38:281.

    Article  CAS  Google Scholar 

  • Korytár P, Janssen HG, Matisova E, Brinkman UAT. Practical fast gas chromatography: methods, instrumentation and applications. Trends Anal Chem. 2002;21:558–72.

    Article  Google Scholar 

  • Loyd RJ, Ayers BO, Karasek FW. Optimization of resolution- time ratio packed chromatographic columns. Anal Chem. 1960;32:698.

    Article  CAS  Google Scholar 

  • Martin AJ. Linear programmed temperature gas chromatography to 500°C. In: Edinburgh Symposium, London, Butterworths; 1960. p. 208–10.

    Google Scholar 

  • Overton EB, Carney KR. New horizons in gas chromatography: field applications of microminiaturized gas chromatographic techniques. Trends Anal Chem. 1994;13:252–7.

    Article  CAS  Google Scholar 

  • Van Deursen MM. Novel concepts for fast capillary gas chromatography. Dissertation thesis, Eindhoven University of Technology, The Netherlands; 2002.

    Google Scholar 

  • Van Deursen M, Beens J, Cramers CA. Possibilities and limitations of fast temperature programming as a route towards fast GC. J High Resolut Chromatogr. 1999;22:509–13.

    Article  Google Scholar 

  • Van Ysacker PG, Snijders HM, Janssen HGM, Cramers CA. The use of non-splitting injection techniques for trace analysis in narrow-bore capillary gas chromatography. J High Resolut Chromatogr. 1998;21:491–7.

    Article  Google Scholar 

  • Wiedeme RT, McKinley SL, Rendl TW. Advantages of wide-bore capillary columns. Am Lab. 1986.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Cristina Cruz-Hernandez .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer Science+Business Media B.V.

About this entry

Cite this entry

Cruz-Hernandez, C., Destaillats, F. (2016). Gas Chromatography of Fatty Acid Methyl Esters: Fast Analysis. In: Wenk, M. (eds) Encyclopedia of Lipidomics. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-7864-1_104-1

Download citation

  • DOI: https://doi.org/10.1007/978-94-007-7864-1_104-1

  • Received:

  • Accepted:

  • Published:

  • Publisher Name: Springer, Dordrecht

  • Online ISBN: 978-94-007-7864-1

  • eBook Packages: Springer Reference Biomedicine and Life SciencesReference Module Biomedical and Life Sciences

Publish with us

Policies and ethics