Skip to main content
Log in

Reduction of dioxin/furan emissions in the waste gas from electric arc furnaces

Reduktion von Dioxin/Furan-Emissionen in Abgasen von Elektrolichtbogenöfen

  • Originalarbeiten
  • Published:
BHM Berg- und Hüttenmännische Monatshefte Aims and scope Submit manuscript

Abstract

The iron and steel industry is under considerable pressure to continuously reduce the levels of generated dioxins and other harmful emissions from process offgas. In the early 1990s this industry commenced with the investigation of new offgas cleaning systems for sinter plants and electric arc furnaces (EAF) which resulted in a considerably improved offgas cleaning efficiency. The global tendency in the steel industry towards an increased application of the electric arc furnace for the production of steel and especially the introduction of scrap-pre-heating technologies in the late 1980s resulted in increased demands for VOC and dioxin reduction technologies. This paper presents an overview of the state-of-the-art of EAF offgas systems and its components with a special focus on the organic components of the offgas.

Zusammenfassung

Seit mehr als einem Jahrzehnt steht die Eisen- und Stahlindustrie unter erheblichem Druck, die gefährlichen Dioxin-Emissionen aus den Prozessabgasen zu reduzieren. In den frühen 90er-Jahren begann daher die Industrie mit der Entwicklung von neuen effizienten Abgassystemen für Sinteranlagen und Elektrolichtbogenöfen (EAF). Weltweit geht der Trend in der Stahlerzeugung in Richtung Elektrostahlherstellung über den Elektrolichtbogenofen. Speziell die Einführung von Technologien mit Schrottvorwärmung Ende der 80er-Jahre führte zu einem erhöhten Bedarf an Technologien zur Reduktion von VOC und Dioxin-Emissionen. Dieser Artikel gibt einen Überblick über den Stand der Technik auf dem Gebiet der EAF Abgassysteme und ihren Komponenten mit Schwerpunkt auf organischen Schadstoffen im Abgas.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Theobald, W.: Ermittlung und Verminderung der Emissionen von halogenierten Dioxinen und Furanen aus thermischen Prozessen_ — Untersuchungen der Emissionen polychlorierter Dibenzodioxine und-furane und von Schwermetallen aus Anlagen der Stahlerzeugung. Umweltbundesamt Abschlussbericht 10403365/01, Deutschland (1995).

  2. alsleben D., V. Dombrowski, A. Eggers, H. Fuchs undH. Schimansky: Verminderung des Schadstoffgehaltes insbesondere an PCDD/PCDF in den Abgasen eines Elektrostahlwerkes. Untersuchungen der Auswirkungen verschiedener Einflussgrößen auf das Emissionsverhalten der Anlage und zur Festlegung der optimalen Fahrweise. Umweltbundesamt Forschungsbericht UBA-FB-III2.2-50441-4/89, Deutschland Dezember (2000).

  3. Ballschmiter, K., undR. Bacher: Dioxine: Chemie, Analytik, Vorkommen, Umweltverhalten und Toxikologie der halogenierten Dibenzo-p-dioxine und Dibenzofurane. VCH-Weinheim, (1996) ISBN 3-527-28768-X.

  4. Huang, H., undA. Buekens: Chemical kinetic modelling of PCDD formation chlorphenol catalysed by incinerator fly ash. Chemosphere 41 (2000), 943–951.

    Article  Google Scholar 

  5. Haissig, M., J. Lehner, T. Glitz andV. Knoth: Waste Gas Management. presented at AISE Conference Sep. 23–26 (2001) Cleveland, Ohio.

  6. Lehner J., A. Friedacher, L. Gould andW. Fingerhut: Low-cost solutions for the removal of Dioxin from EAF offgas. STEEL TIMES International vol. 27 no. 06, Sept. (2003), 40–44.

    Google Scholar 

  7. Esser-Schmittman, W., andJ. Wirling: Implementation of process-integrated waste gas cleaning using activated lignite. Paper presented at the Hazardous Waste Combustors Specialty Conference, March 28–30 (2001), Kansas City.

  8. Prüm, Ch., Ch. Werner andJ. Wirling: Reducing dioxin emissions in electric steel mills. MPT International Vol- ume 27 issue No. 1 (2005), 36–42.

    Google Scholar 

  9. Kaiser, E., J. Lehner, M. Bourge andV. Knoth: Emission control for arc furnace technology. Presented at METEC Congress, June 13–15 (1999), Düsseldorf.

  10. Steger P. L., A. Friedacher, J. Lehner andW. Gebert: Waste gas purification and waste-free plant concept for EAF. Presented at Middle East Steel Congress May 23–25 (1999), Qatar.

  11. Werner, Ch.: Investigation into techniques to reduce dioxin and furan emissions from the electric arc furnace. Proceedings of the International Conference on “Clean Technologies in the Steel Industry” Balatonfüred, Hungary, 6–8 June (2005), 301–306.

  12. European Commission: Integrated Pollution Prevention and Control (IPPC) — Best Available Techniques Reference Document on the Production of Iron and Steel. European IPPC Bureau (2000).

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Friedacher, A., Lehner, J., Gould, L. et al. Reduction of dioxin/furan emissions in the waste gas from electric arc furnaces. Berg Huettenmaenn Monatsh 151, 131–136 (2006). https://doi.org/10.1007/BF03165187

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03165187

Keywords

Navigation