INTRODUCTION

The transdermal drug delivery can no longer be considered a “novel” drug delivery technology. Over the past few decades, there has been a tremendous growth in the understanding of the technology involved in the development of transdermal drug delivery systems (TDDS). TDDS are designed to deliver the drug(s) across the skin at a controlled rate into the systemic circulation. TDDS offers several, well-documented advantages over the conventional oral and parenteral routes of drug delivery (13). These include therapeutic advantages such as sustained delivery of drugs, avoiding pre-systemic metabolism, avoiding hostile gastrointestinal factors (e.g., gastric pH, gastric transit time, etc.), suitability for drugs with short biological half-life and narrow therapeutic index, and relatively lower fluctuations observed in the drug plasma levels. Some of the patient compliance benefits include non-invasive drug administration, flexibility in the dosing frequency, suitability for self-medication, and better control of the side effects/adverse effects. TDDS are also associated with uncommon limitations such as suitability limited to potent (low dose) drugs, stratum corneum as a barrier to drug absorption, requirement of the ideal permeability characteristics of the drugs, non-suitability for tolerance-inducing drugs, and costly nature of the dosage form (1,4,5). Nevertheless, several transdermal formulations consisting of drugs over a range of pharmacological classes are approved to be marketed in the USA or are in different stages of development (4,5). The TDDS market is reported to be worth $12.7 billion in 2005 and is anticipated to be over $30 billion this year (2015) (4).

Stratum corneum, being a natural protector, limits the penetration of the xenobiotics. It is known to be a major rate-limiting factor to the transdermal absorption of a drug and its subsequent systemic bioavailability (6). The role of permeation enhancers in the formulation of transdermal systems was envisaged early on to overcome the challenge of limited transdermal absorption of a drug (7,8). Permeation enhancers originating from a wide variety of chemical classes, including alcohols, fatty acids, amines, esters, amides, hydrocarbons, surfactants, etc., have been explored to enhance the transdermal absorption of the drugs (9). The permeation enhancers act mainly by disrupting the lipid bilayers within the stratum corneum (10). The disruption of the natural integrity of the stratum corneum is known to cause skin irritation, and thus, a rational selection of a permeation enhancer that enhances the drug permeation through the skin with minimal alteration of the structure and functions of the skin is of critical importance (11). Terpenes are naturally occurring volatile oils that have gained popularity in the recent years as choice enhancers in transdermal formulations (12). Terpenes are also known to be versatile in their applications, i.e., they are suitable for the percutaneous penetration and absorption enhancement of both hydrophilic and lipophilic drugs (13,14). Moreover, compared with surfactants and other permeation enhancers, terpenes, when used in lower concentrations, exhibit relatively lower percutaneous irritancy (15).

Other key components of transdermal formulations apart from the permeation enhancers include the film-forming polymers and one or more hydrophilic polymers incorporated as rate-controlling matrix formers (1618). These excipients are available in a wide range of physicochemical properties and grades. The nature and the amount of these excipients incorporated in a TDDS can have a significant influence on the manufacturability, quality, and performance of the final drug product. Most of the studies report the incorporation of a variety of these excipients in the formulation of transdermal delivery systems (1921). However, the studies that evaluate the influence of these formulation variables in a systematic, quantitative manner are few and far between.

The present investigation was aimed at quantitatively and systematically assessing the influence of the ratio of two formulation variables, i.e., a hydrophilic polymer and a film-forming polymer, on the physicochemical and functional attributes of transdermal films. The study was carried out in three stages. First, several terpenes were evaluated for their permeation-enhancing efficiency across the excised hairless rat skin. Granisetron (GRN) was chosen as a model drug for this study. The physicochemical properties of GRN allow it to be incorporated into a transdermal drug delivery system. These properties include low molecular mass, high lipid solubility, low therapeutic dose, as well as a high degree of first-pass metabolism. Next, several transdermal film formulations containing different ratios of a hydrophilic polymer (Methocel® E15) and a film-forming polymer (Eudragit® RL 100 or Eudragit® RS 100) were prepared. Finally, the prepared films were evaluated for their physical, chemical, in vitro drug release, and ex vivo drug permeation properties. The results were statistically analyzed to understand the influence of these formulation variables on the prepared films.

MATERIALS AND METHODS

Materials

Granisetron samples were obtained from Wockhardt Limited (India). Hydroxypropyl methycellulose (Methocel® E15) was obtained from Colorcon Asia Pvt. Ltd. (India). Eudragit® RL 100 and Eudragit® RS 100 were obtained from Evonik Degussa India Pvt. Ltd. (India). Eugenol and d-limonene were obtained from Keva Fragrances Ltd. (India). α-Terpineol and menthol were obtained from Workwell (India). ScotchPak™ 1109 backing membrane was obtained from 3M Drug Delivery Systems, USA. Other solvents and reagents used were of analytical grade.

Methods

Preparation of Biological Membrane for Permeability Studies

Ethical clearance for the handling of experimental animals was obtained from the institutional animal ethics committee (IAEC) formed for this purpose. Male Sprague Dawley® rats weighing 200 to 250 g were euthanized by cervical dislocation, and the dorsal skin was removed. After removing the epidermal hair and the subcutaneous fat, the skin was thoroughly washed with phosphate-buffered saline (PBS, pH 7.4) and placed overnight in contact with the receptor phase, i.e., fresh PBS, pH 7.4. The overnight-stored rat skin was used for ex vivo permeability studies.

Effect of Penetration Enhancers on Permeation of Granisetron

The ex vivo permeation studies were carried out in a Franz diffusion cell with a diffusion surface area of 2.5 cm2. The biological membrane, with the stratum corneum facing the donor segment, was affixed to the diffusion cell. GRN solution (1 mg/ml, in PBS, pH 7.4) was placed in the donor compartment containing d-limonene (5% v/v), α-terpineol (5% v/v), eugenol (5% v/v), or menthol (5% v/v). The absence of penetration enhancer served as a control. The receiver compartment contained magnetically stirred PBS (18 ml, pH 7.4), maintained at 37 ± 0.5°C. The amount of drug permeated through the biological membrane was determined by analyzing the drug concentration in the filtered samples (1 ml), withdrawn at predetermined time intervals. The samples were analyzed using a modified reverse-phase HPLC at a wavelength of 305 nm. The cumulative amount (%) of drug permeated was plotted against time.

Permeation Data Analysis

The drug concentration in the permeate was corrected for sampling effects according to the equation described by Hayton et al. (Eq. (1)) (22):

$$ {C}_n^{\prime }={C}_n\left(\frac{V_{\mathrm{T}}}{V_{\mathrm{T}}-{V}_{\mathrm{s}}}\right)\left(\frac{C_{n-1}^{\prime }}{C_{n-1}}\right) $$
(1)

where \( {C}_n^{\prime } \) is the corrected concentration of the nth sample, \( {C}_n \) is the measured concentration of GRN in the nth sample, \( {C}_{n-1} \) is the measured concentration of the GRN in the (n − 1)th sample, V T is the total volume of the receiver fluid, and V s is the volume of the sample drawn. The steady-state flux (\( {J}_{\mathrm{ss}} \)) and the permeability coefficient (K p) were calculated using Eqs. (2) and (3), respectively, as described by Barry (23):

$$ {J}_{\mathrm{ss}}={\left(\frac{dQ}{dt}\right)}_{\mathrm{ss}}\times \frac{1}{A} $$
(2)
$$ {K}_{\mathrm{p}}=\frac{J_{\mathrm{s}\mathrm{s}}}{C_{\mathrm{s}}} $$
(3)

where A is the effective diffusion area, C s is the concentration in the saturated solution, and \( {\left(\frac{dQ}{dt}\right)}_{\mathrm{ss}} \) is the steady-state slope. The penetration-enhancing effect of the terpenes was calculated as enhancement ratio (ER), using the following equation (Eq. (4)) (12):

$$ \mathrm{E}\mathrm{R}=\frac{K_{\mathrm{P}}\ \left(\mathrm{with}\ \mathrm{penetration}\ \mathrm{enhancer}\right)}{K_{\mathrm{P}}\ \left(\mathrm{with}\mathrm{out}\ \mathrm{penetration}\ \mathrm{enhancer}\right)} $$
(4)

Drug-Polymer Compatibility Studies

The preliminary physicochemical compatibility between GRN and the polymers used in the films was evaluated using differential scanning calorimetry (DSC) and the Fourier transform infrared (FTIR) spectroscopy.

Differential Scanning Calorimetry

The thermal analysis of GRN, the pure polymers, and their physical mixtures with GRN was carried out using a differential scanning calorimeter (Model: Q10, TA Instruments, Inc., New Castle, DE, USA). The analysis was done under a purge of dry nitrogen gas (50 ml/min). High-purity indium was used to calibrate the heat flow and the heat capacity of the instrument. The samples (2.5–5 mg) were sealed in aluminum pans with the lids using a crimper. Each sample was subjected to a single heating cycle from 25 to 400°C at a heating rate of 10°C/min. The results were analyzed using the Universal Analysis software version 4.5A, build 4.5.0.5 (TA Instruments, Inc., New Castle, DE, USA).

Fourier Transform Infrared Spectroscopy

The infrared spectra of GRN, the polymers, and their physical mixtures with GRN were obtained from an FTIR spectrophotometer (Model: IR Prestige-21, Shimadzu, Japan) equipped with an attenuated total reflectance (ATR) accessory. The analysis of the samples was carried out using diffuse reflectance spectroscopy (DRS)-FTIR with KBr. The influence of the residual moisture was theoretically removed by subjecting the samples to vacuum drying before obtaining any spectra. Each sample analysis included 45 scans, at a resolution of 4 cm−1 from 4000 to 600 cm−1.

Preparation and Characterization of Granisetron Transdermal Films

As shown in the Table I, ten matrix-type transdermal film formulations containing GRN, Methocel® E15, and Eudragit® RL 100 or Eudragit® RS 100 were prepared. The preparation method as described previously by Kusum Devi et al. was followed (17). Briefly, the drug and the polymers, propylene glycol (plasticizer), and d-limonene (penetration enhancer) were dispersed in ethanol (casting solvent), and the polymeric dispersion was degassed by sonication. The polymeric dispersion of the drug was then poured into a circular well formed by a glass mold (5.68 cm2, fabricated in the laboratory for the purpose), placed in a standard Petri dish containing mercury (Fig. 1). The rate of solvent evaporation was qualitatively controlled by covering the mold with an inverted funnel. The dry films were obtained after the evaporation of the casting solvent overnight in a solvent hood. The dried formulation films were carefully cut into uniform sizes to contain a theoretical equivalent of ∼4 mg of the drug per film. This dose of GRN (4 mg per film) was targeted based on the recommended therapeutic doses of GRN for chemotherapy-induced nausea and vomiting (24). Preliminary studies based on film dimensions showed that GRN (9.1% w/w) in the formulations achieved this target dose per film. A backing membrane was attached to the prepared films, and the films were stored in a desiccator, between the sheets of glassine paper.

Table I Composition of the Transdermal Films
Fig. 1
figure 1

Preparation of GRN films. a Circular glass mold in a Petri dish filled with mercury, b Mold covered with an inverted funnel to qualitatively control solvent evaporation, and c Dried GRN film

Evaluation of Physicochemical Properties of Films

Weight Variation

The weight variation of the prepared films was evaluated by individually weighing three randomly selected films of each prepared formulation. The mean weight and the standard deviation for each formulation film were calculated and recorded.

Thickness

The thickness of prepared films was measured using a digital micrometer screw gauge with a least count of 0.001 mm (Mitutoyo, Japan) at three different locations on the film. Three randomly selected films of each formulation were evaluated for thickness. The mean thickness (mm) and the standard deviation for each formulation film were calculated and recorded.

Tensile Strength

The mechanical properties of the prepared polymer films were determined by measuring their tensile strength as described previously by Yener et al. (25). According to the American Society for Testing and Materials (ASTM), the tensile strength of polymeric films is a measure of the minimum stretching force applied to the sample that results in the breaking of the film. The tensile strength measurements were carried out on dumbbell-shaped films (2.5 × 1 cm). The formulation films were subjected to a pulling force by hanging standard weights from the films and measuring the force (kg/mm2) using a load cell.

Percentage Elongation

The determination of longitudinal strain (percentage elongation at break) was carried out as described by Khanna et al. (26). The percentage elongation at break for the film samples was calculated using the following formula (Eq. (5)):

$$ \%\;\mathrm{elongation}\ \mathrm{at}\ \mathrm{break}=\frac{\mathrm{increase}\ \mathrm{in}\ \mathrm{length}}{\mathrm{initial}\ \mathrm{length}}\times 100 $$
(5)

Folding Endurance

The folding endurance was evaluated by repeatedly folding a small strip of film (2.5 cm2) at the same location to the point of breaking (17). The folding endurance value is typically described as the number of times a film may be folded at the same location before it breaks. Three randomly selected samples of each prepared formulation film were evaluated for the folding endurance. The mean and the standard deviation for each formulation were calculated and recorded.

Drug Content Uniformity

The GRN content was assayed on ten randomly selected films from each formulation. The prepared films were dissolved in ethanol (2 ml), and the volume was adjusted to 100 ml with PBS (pH 7.4). The solution was filtered and suitably diluted, and the GRN content of each film was determined using a modified reverse-phase HPLC (RP-HPLC) method previously described by Pinguet et al. (27). Briefly, the HPLC system (Model: Prominence, Shimadzu Corporation, Kyoto, Japan) with LCsolution software, equipped with a LC-20AD HPLC pump, a manual rheodyne sample injector, and a SPD-M20A detector, was used. The mobile phase was composed of methanol/0.02 M phosphate buffer (pH 4.0) (40:60, v/v), at a flow rate of 1 ml/min. A Hypersil-Keystone C-18 column (250 × 4.6 mm, 5 μm) was used as a stationary phase, and the GRN samples were detected by ultraviolet (UV) detection at 305 nm. The calibration of the peak area against concentration of GRN was found to be y = 10,498x − 73.42 with R 2 = 0.9997 for the GRN concentration range of 2–10 μg/ml (where y = peak area and x = GRN concentration), and the limit of detection was found to be 0.02 μg/ml.

Flatness

A method previously described by Kshirsagar et al. was used to calculate the flatness of the prepared films (20). Briefly, the prepared films were cut into uniform longitudinal strips. The length of each strip was then measured accurately, and the variations in length due to the non-uniformity of flatness were measured. The flatness of the strips was calculated by measuring the percent constriction using Eq. (6). A constriction value of 0% was assumed to indicate 100% flatness. Three randomly selected films of each formulation were evaluated for flatness. The mean and the standard deviation values for each formulation were calculated and recorded:

$$ \%\;\mathrm{Constriction}=\frac{l_1-{l}_2}{l_2}\times 100 $$
(6)

Percent Moisture Content

Three randomly selected films of each prepared formulation were marked, then weighed individually, and placed in a desiccator at room temperature (25 ± 0.5°C). The films were then removed and weighed at predetermined intervals until a constant weight was achieved. The moisture content (%) was calculated as a difference between the initial and the final weight with respect to the final weight (Eq. (7)) (28). The mean and the standard deviation values for each formulation were calculated and recorded.

$$ \%\ \mathrm{moisture}\ \mathrm{content}=\frac{\mathrm{final}\ \mathrm{wt}.-\mathrm{initial}\ \mathrm{wt}.}{\mathrm{initial}\ \mathrm{wt}.}\times 100 $$
(7)

Percentage Moisture Uptake

The physical stability and the integrity of the polymeric films in humid environments are typically evaluated by calculating the percent moisture absorption at elevated humidity conditions.

The extent of moisture uptake by the prepared films at elevated humidities and at room temperature (25 ± 0.5°C) was determined using the method described by Kusum Devi et al. (17). Briefly, saturated solutions of ammonium dihydrogen phosphate (60 ± 5% RH), sodium chloride (75 ± 5% RH), and potassium nitrate (90 ± 5% RH) were placed in three separate desiccators respectively and allowed to equilibrate for 24 h to attain the respective humidity values (29). Three randomly selected films from each formulation were weighed and placed in each desiccator. The films were then removed at predetermined intervals and carefully weighed, until a constant weight was achieved (17). The percentage moisture uptake by the films was calculated using Eq. (8):

$$ \%\ \mathrm{moisure}\ \mathrm{uptake}=\frac{\mathrm{final}\ \mathrm{wt}.-\mathrm{initial}\ \mathrm{wt}.}{\mathrm{initial}\ \mathrm{wt}.}\times 100 $$
(8)

Water Vapor Transmission Rate

The water vapor transmission rate (WVTR) is the amount of moisture transmitted through a unit area of film in a given duration at room temperature (25 ± 0.5°C). The WVTR for the prepared films was calculated using a method reported earlier (17). Briefly, glass cells were filled with 2 g of anhydrous calcium chloride, and a formulation film of specified area was affixed onto the cell rim. The cells were accurately weighed and placed in desiccators containing saturated solutions of ammonium dihydrogen phosphate (60 ± 5% RH), sodium chloride (75 ± 5% RH), or potassium nitrate (90 ± 5% RH), respectively (29). The glass cells were removed from the desiccators at regular intervals and weighed accurately. The process was continued until a constant weight was achieved. The amount of water vapor transmitted was determined using the formula below (Eq. (9)):

$$ \mathrm{WVTR}=\frac{\mathrm{final}\ \mathrm{weight}-\mathrm{initial}\ \mathrm{weight}}{\mathrm{area}\times \mathrm{time}} $$
(9)

In Vitro Release Studies

The in vitro release of GRN from the prepared formulation films was determined using a Franz diffusion cell. Three randomly selected films of each formulation were used for the analysis of drug release from the prepared films. The film, supported with a backing membrane, was placed in the donor compartment of the cell. The donor compartment was separated from the receptor compartment by a dialysis membrane (Himedia®), with a molecular weight cutoff between 12,000 and 14,000. The dialysis membrane was previously stored in PBS (pH 7.4) for 24 h. The receptor compartment contained magnetically stirred PBS (18 ml, pH 7.4) maintained at 37 ± 0.5°C. The amount of GRN released was determined by analyzing the drug concentration in the filtered samples (1 ml), withdrawn at predetermined time intervals. The samples were analyzed using a modified RP-HPLC at a wavelength of 305 nm. The cumulative drug release (%) was calculated and plotted against time.

Ex Vivo Permeation Studies

The ex vivo permeation studies were carried out using a Franz diffusion cell mounted with excised rat skin, with the stratum corneum facing the donor compartment. The drug-releasing surface of the transdermal film under evaluation was placed in contact with the stratum corneum side of the skin. The receiver compartment contained magnetically stirred PBS (18 ml, pH 7.4), maintained at 37 ± 0.5°C. The amount of GRN permeated was determined by analyzing the drug concentration in the filtered samples (1 ml), withdrawn at predetermined time intervals. The samples were analyzed using a modified RP-HPLC at a wavelength of 305 nm. The cumulative GRN permeated (%) was calculated and plotted against time.

The target flux was calculated using the equation described previously by Suwanpidokkul et al. (Eq. (10)) (30):

$$ {J}_{\mathrm{t}\mathrm{arget}}=\frac{C_{\mathrm{SS}}{\mathrm{Cl}}_{\mathrm{t}}\mathrm{B}\mathrm{W}}{A} $$
(10)

where A represents the surface area of the transdermal film (i.e., 2.5 cm2); BW, the standard human body weight of 60 kg; C SS, the GRN concentration at the therapeutic level (3.07 μg/l); and Clt, the total clearance (0.52 l/h). The calculated target flux value for GRN was 42.57 μg/h/cm2.

Statistical Analysis

The statistical analysis was carried out by a two-way analysis of variance (ANOVA), followed by Bonferroni post-test using GraphPad® Prism® software version 5.03 (San Diego, CA). The results were expressed as mean ± standard deviation (SD). The differences between the means were considered to be significant if the P value was <0.05.

RESULTS

Effect of Penetration Enhancers on the Permeation of Granisetron

The influence of selected terpenes on the cumulative permeation of GRN through rat skin is shown in Fig. 2. The penetration-enhancing efficiency of these terpenes was found to be in the order d-limonene (90%) > α-terpineol (72%) > eugenol (60%) > menthol (48%). All tested terpenes demonstrated a significant (P < 0.05) improvement in the permeation of GRN across the rat skin compared with the control (22%) at the end of 24 h. These results are in agreement with those reported previously.

Fig. 2
figure 2

Effect of penetration enhancers on the permeation of GRN. All values are mean ± SD (n = 3). *P < 0.01, compared to control

The calculated transdermal flux values of GRN obtained with d-limonene, α-terpineol, eugenol, and menthol were found to be 33.37 ± 2.16, 26.70 ± 0.84, 22.25 ± 1.58, and 17.80 ± 1.05 μg/cm2/h, respectively. These values were found to be significantly (P < 0.05) higher compared with those of the control (8.16 ± 0.62 μg/cm2/h). In addition, the calculated permeability coefficient values for d-limonene, α-terpineol, eugenol, and menthol were found to be 4.08 ± 0.27, 3.27 ± 0.21, 2.73 ± 0.16, and 2.18 ± 0.11 cm/h × 10−2, respectively.

Drug-Polymer Compatibility Studies

The DSC thermogram of pure GRN showed a sharp endothermic peak at ∼300°C, corresponding to the GRN melting point (thermograms not shown). The appearance of a sharp endothermic peak is typically attributable to the crystalline nature of the materials. The DSC thermogram of Methocel® E15, Eudragit® RL 100, and Eudragit® RS 100 revealed broad, undefined peaks over a temperature range of 60–240°C. Such broad endothermic peaks, mainly due to the dehydration process, are typically observed with predominantly amorphous polymers.

The FTIR spectral analysis of pure GRN showed the main peaks at wave numbers 3246, 1647, 1557, 1478, and 1248 cm−1, confirming the purity of the drug (Fig. 3). The FTIR spectra of the ternary mixtures, GRN:Methocel® E15:Eudragit® RL 100 (1:1:1) and GRN:Methocel® E15:Eudragit® RS 100 (1:1:1), showed that the major peaks of GRN were retained and observed at wave numbers 3245, 1646, 1561, 1471, and 1248 cm−1. The presence of the polymers did not appear to significantly affect the integrity of the GRN peaks.

Fig. 3
figure 3

FTIR analysis of the drug and the polymers. a Granisetron, b granisetron:Methocel® E15:Eudragit® RL 100 (1:1:1), and c granisetron:Methocel® E15:Eudragit® RS 100 (1:1:1)

Physicochemical Properties of the Films

The results of the physicochemical properties of the prepared transdermal matrix films are shown in Table II. The mean weights of the prepared films from all ten formulations ranged between 55 and 58 mg, and no significant differences were observed among the formulations evaluated. The changes in the ratio of the incorporated polymers in the formulation did not appear to have a statistically significant influence on the weight of the films. The thickness of the prepared films ranged between 92 and 107 μm. The film thickness appeared to decrease with decreasing ratio of the Methocel® E15:Eudragit® polymer in the formulations. These results are in agreement with those reported previously (31,32). The results of the flatness study showed that the formulation films had a negligible change in the length along the longitudinally cut edges, indicating a near 100% flatness. The films from all tested formulations appeared to have a smooth, flat surface, without any visible signs of constriction.

Table II Physicochemical Properties of GRN Films

The results of the content uniformity assay of the prepared films are shown in Table II. The GRN content of the films from different formulations, as obtained from the HPLC assay, ranged from 98 to 100% w/w of the theoretical concentration. The drug content was found to be statistically similar across different formulations. The results indicated that the process employed to prepare films in this study was robust and capable of producing films without a significant variation. The folding endurance test results (Table II) showed that the films prepared from all formulations endured at least 250 strokes of folding/unfolding at the same location before revealing any signs of cracking/breaking. These results were found to be higher than those reported in the literature for similar formulations (17). These results demonstrated the sturdiness of the films in maintaining their integrity with general skin folding when applied.

The moisture content of the prepared films from all the formulations at ambient conditions ranged between 2 and 7% w/w. The composition of Methocel® E15 in the formulations was found to influence the moisture content of the films (Fig. 4a, b). The moisture content increased in a linear manner with increasing levels of Methocel® E15 for formulations containing Eudragit® RL 100 (R 2 = 0.9787) or Eudragit® RS 100 (R 2 = 0.9807). The moisture content among the formulations containing similar concentrations of either Eudragit® RL 100 or Eudragit® RS 100 was not found to be significantly different.

Fig. 4
figure 4

The effect of Methocel® E15 levels on the moisture content (%) of the prepared films. a Formulations containing Eudragit® RL 100. b Formulations containing Eudragit® RS 100

The results of the moisture uptake by the prepared films at elevated conditions of humidity, i.e., 60% RH, 75% RH, and 90% RH, are shown in Fig. 5a, b. Similar to the moisture content results, the moisture uptake by the prepared formulation films appeared to depend on the amount of Methocel® E15 in the formulations. For the formulations containing Eudragit® RL 100 (Fig. 5a), the moisture uptake increased linearly with increasing Methocel® E15 at 60% RH (R 2 = 0.9568), 75% RH (R 2 = 0.9989), and 90% RH (R 2 = 0.9982). Similarly, for the formulations containing Eudragit® RS 100 (Fig. 5b), the moisture uptake increased linearly with increasing Methocel® E15 at 60% RH (R 2 = 0.9485), 75% RH (R 2 = 0.992), and 90% RH (R 2 = 0.9992). As observed with moisture content results, the moisture uptake among the formulations containing similar concentrations of either Eudragit® RL 100 or Eudragit® RS 100 was not found to be significantly different.

Fig. 5
figure 5

The effect of Methocel® E15 levels on the moisture uptake (%) of the prepared films. a Formulations containing Eudragit® RL 100. b Formulations containing Eudragit® RS 100

The water vapor transmission rates (WVTR) in the prepared films were found to range between 0.09 and 0.56 mg/cm2/h. These results were in agreement with those reported previously (21,33). Similar to the results obtained from the moisture content and moisture uptake studies, the WVTR of the prepared films appeared to correlate linearly with Methocel® E15 levels in the formulations. For the formulations containing Eudragit® RL 100 (Fig. 6a), the WVTR increased linearly with increasing Methocel® E15 at 60% RH (R 2 = 0.8542), 75% RH (R 2 = 0.9991), and 90% RH (R 2 = 0.9822). Similarly, for the formulations containing Eudragit® RS 100 (Fig. 6b), the moisture uptake increased linearly with increasing Methocel® E15 at 60% RH (R 2 = 0.9454), 75% RH (R 2 = 0.9914), and 90% RH (R 2 = 0.9904).

Fig. 6
figure 6

The effect of Methocel® E15 levels on the water vapor transmission rate of the films. a Formulations containing Eudragit® RL 100. b Formulations containing Eudragit® RS 100

In Vitro Drug Release

The results of the in vitro drug release from transdermal films are shown in Fig. 7a, b and Table III. Figure 7a shows the influence of the ratio of Methocel® E15 and Eudragit® RL 100 on the release of GRN from the prepared transdermal films. It was observed that the formulation F1 (with the highest ratio of Methocel® E15:Eudragit® RL 100) exhibited the highest cumulative amount of GRN released (Table III). For the subsequent formulations, i.e., F2 to F5, the release of GRN was found to be progressively slower. Similar results were observed with formulations containing Eudragit® RS 100 (Fig. 7b). The formulation F6 (with the highest ratio of Methocel® E15:Eudragit® RS 100) exhibited the highest cumulative amount of GRN released, and for the subsequent formulations, i.e., F7 to F10, the release of GRN was found be progressively slower. Thus, compared with the control, the GRN release appeared to be significantly influenced by the ratio of Methocel® E15 and Eudragit® polymers. The enhancement of drug release in the presence of a hydrophilic component to an insoluble film former has been reported earlier (34).

Fig. 7
figure 7

The in vitro release of GRN from transdermal films. a Formulations containing Eudragit® RL 100. b Formulations containing Eudragit® RS 100 (n = 3)

Table III The In Vitro Drug Release, Ex Vivo Skin Permeation, Transdermal Flux, Permeability Coefficient, and Enhancement Ratio of GRN Films

Ex Vivo Drug Permeation

The results of the ex vivo drug permeation studies (across the excised rat skin) from transdermal films are shown in Fig. 8a, b and Table III. Similar to the results obtained from the in vitro drug release studies, it was observed that the formulation F1 (with the highest ratio of Methocel® E15:Eudragit® RL 100) exhibited the highest cumulative amount of GRN permeated (Table III). For the subsequent formulations, i.e., F2 to F5, the permeation of GRN was found to be progressively slower (Fig. 8a). Similar results were observed with formulations containing Eudragit® RS 100 (Fig. 8b). The formulation F6 (with the highest ratio of Methocel® E15:Eudragit® RS 100) exhibited the highest cumulative amount of GRN permeated, and for the subsequent formulations, i.e., F7 to F10, the permeation of GRN was found be progressively slower. Thus, GRN permeation through the rat skin also appeared to be influenced by the ratio of Methocel® E15 and Eudragit® polymers.

Fig. 8
figure 8

The ex vivo permeation of GRN from transdermal films. a Formulations containing Eudragit® RL 100. b Formulations containing Eudragit® RS 100 (n = 3)

Transdermal Flux, Permeation Coefficient, and Enhancement Ratio

The results of the calculated steady-state transdermal flux values (J ss) are shown in Fig. 9a, b and Table III. The J ss values were found to increase in a linear manner with increasing levels of Methocel® E15 in the formulations containing Eudragit® RL 100 (R 2 = 0.9868) (Fig. 9a) or Eudragit® RS 100 (R 2 = 0.9915) (Fig. 9b). The J ss values among the formulations containing similar concentrations of either Eudragit® RL 100 or Eudragit® RS 100 were not found to be significantly different.

Fig. 9
figure 9

Transdermal flux of GRN from the film formulations. a Formulations containing Eudragit® RL 100. b Formulations containing Eudragit® RS 100

Similar trends were observed in the calculated permeability coefficient and the enhancement ratio results for the formulations (Fig. 10a, b and Table III). For the formulations containing Eudragit® RL 100, the permeability coefficient (R 2 = 0.9229) and the enhancement ratio (R 2 = 0.9864) values appeared to vary linearly as a function of Methocel® E15 composition.

Fig. 10
figure 10

Permeability coefficient and enhancement ratio of GRN from transdermal films. Values are mean ± SD (n = 3)

Similarly, for the formulations containing Eudragit® RL 100, increasing levels of Methocel® E15 resulted in a linear increase in the permeability coefficient (R 2 = 0.9139) and the enhancement ratio (R 2 = 0.9915) values.

DISCUSSION

Terpenes are known to function as permeation enhancers when incorporated in transdermal formulations (35). In the current study, the comparative permeation-enhancing efficiency of four terpenes, i.e., d-limonene, α-terpineol, eugenol, and menthol, was evaluated. The hydrocarbon- or non-polar-group-containing terpenes such as limonene typically provide a better penetration-enhancing effect for the lipophilic drugs, compared with the polar terpenes. d-Limonene is previously reported to be effective in enhancing the transport of lipophilic molecules such as indomethacin, midazolam, and estradiol (36). d-Limonene is a hydrophobic terpene, lacking a hydroxyl group (log P 4.58 ± 0.23), and the mechanism of its permeation-enhancing effects is thought to be due to an increase in the partitioning of the drug molecules into the lipid bilayer of the stratum corneum (37). Based on the results obtained from the GRN permeation, the calculated transdermal flux, and the permeation coefficient values, d-limonene was identified as the best permeation enhancer among the terpenes evaluated. d-Limonene was thus selected to be incorporated into the formulations prepared to further investigate the influence of other formulation variables on the functionality of the transdermal films.

The DSC analysis of the ternary mixtures, GRN:Methocel® E15:Eudragit® RL 100 (1:1:1) and GRN:Methocel® E15:Eudragit® RS 100 (1:1:1), revealed a negligible and a non-significant change in the melting point of GRN (∼300°C) in the presence of these polymers.

Additionally, the melting signal (endotherm) was clearly distinguishable in both ternary mixtures. Since no other endothermic/exothermic event was observed in this region, any interaction or obvious incompatibility between the drug and the polymers can be safely excluded. The DSC results thus indicated the suitability of these polymers to be used in the transdermal film formulations (19). Similarly, the FTIR analysis of the ternary mixtures of the drug and the polymers did not reveal any interferences with the major peaks associated with GRN. The DSC and FTIR results thus indicated that the drug and polymers are compatible. Methocel® E15, Eudragit® RL 100, and Eudragit® RS 100 are commonly used polymers, incorporated in a wide range of controlled/sustained-release matrix-type transdermal drug delivery systems due to their compatibility with several drugs (38).

The prepared transdermal films were evaluated for the physicochemical properties using commonly used, well-established, and standard methods. The physical characteristics of the films such as weight variation, thickness, and flatness were found to be consistent among the formulations and within acceptable limits. The moisture content and the moisture uptake values of the prepared films were found to be dependent on the incorporated hydrophilic polymer ratio. An increase in the moisture content and moisture uptake by polymeric films as a function of increasing levels of hydrophilic polymers has been reported earlier (18,31,32,39). A small amount of moisture in the films is thought to be essential to maintain the stability and integrity of the films and to prevent excessive drying (resulting in brittleness and cracking) of the films (18,39). The water vapor transmission rate (WVTR) is a parameter commonly used to evaluate the amount of moisture transmitted through the transdermal films containing hydrophilic polymers (21,40). The prepared transdermal films showed predictable and linearly proportional WVTR values with increasing Methocel® E15 content. Tanwar et al. have previously reported higher film WVTR values for HPMC-based films and attributed this to the hydrophilicity of the polymer incorporated (33).

The physicochemical properties of the drug and the delivery system, as well as the physiological and physicochemical properties of the biological membrane, typically determine the rate and extent of the drug release from the transdermal films (41). In an attempt to describe the release kinetics of GRN from the prepared transdermal films, the results from the in vitro release studies was fitted to different kinetic models such as the zero-order release, first-order release, Higuchi, and Korsmeyer-Peppas release models (42). The cumulative amount of drug released from the films, when plotted against the square root of time, exhibited release profiles of the drug which appeared to follow the Higuchi model, as evidenced by the range of correlation coefficient values (R 2 = 0.97 to 0.99). The correlation coefficient values for the zero-order (R 2 = 0.93 to 0.95) and the first-order (R 2 = 0.56 to 0.60) kinetics were lower than those for the Higuchi kinetics (Table IV). Korsmeyer et al. used a simple empirical equation (Eq. (11)) to describe the release behavior of molecules from the polymer matrices (16):

$$ \frac{M_t}{M_{\infty }}=K{t}_n $$
(11)
Table IV In Vitro Release Kinetics of GRN Films

where \( \frac{M_t}{M_{\infty }} \) is the fraction of drug released, K is the rate constant, t is time for the drug release, and n is the diffusional exponent for drug release. Peppas stated that, regardless of the mechanism of release, the above equation can describe the drug release from polymer matrices of various geometries. The release mechanism is typically indicated by the value of the diffusional exponent (n). For example, when n = 1, the release can be considered “zero-order” (case II transport), and n = 0.5 indicates a Fickian diffusion-based release; when 0.5 < n < 1.0, diffusion and non-Fickian transport may be involved. Lastly, when n > 1.0, the apparent mechanism is “super case II transport.” The value of n is obtained from the slope of \( \log \frac{M_t}{M_{\infty }} \) vs the log time curve. The n values for the GRN release obtained using this equation (0.53 to 0.75) indicated that the main mechanism of GRN release from the prepared films was general, non-Fickian diffusion. The hydration and subsequent swelling of the incorporated hydrophilic polymer Methocel® E15 may possibly explain the observed mechanism of GRN release.

Overall, the formulations containing Eudragit® RL 100 exhibited GRN release that was higher in rate and extent, compared with those containing Eudragit® RS 100. Eudragit® RL 100 contains a higher proportion of the hydrophilic quaternary ammonium groups compared with Eudragit® RS 100, which may result in a rapid hydration of the matrix and subsequent drug release (33). An increase in the amount and hydrophobicity of the incorporated polymers is known to slow the drug release rates. In such cases, the mechanism of the drug release shifts towards polymer relaxation and matrix erosion (43,44).

A mild burst release of GRN was observed with all formulations. This may be attributed to the direct exposure of the matrix films to dissolution media. Due to the hydrophilic nature of the polymer used, the polymeric matrix may form loose channels within the network, resulting in a rapid release of the drug present in the surface layers of the film. The observed initial release may assist in achieving the therapeutic plasma concentration of the drug in a short time, followed by a constant release over a longer period of time (43,44). The initial burst release was observed to be higher in the matrix film Eudragit® RL 100 polymer compared with Eudragit® RS 100, although this effect was not significant.

The cumulative amount of drug permeated (per square centimeter of films) through the rat abdominal skin, when plotted against time, exhibited permeation profiles that appeared to follow Higuchi’s equation as evidenced by the calculated range of correlation coefficient values (R 2 = 0.98 to 0.99). The correlation coefficient values for the first-order (R 2 = 0.60 to 0.62) and the zero-order (R 2 = 0.96 to 0.98) kinetics were found to be relatively lower than those obtained with the Higuchi kinetics (Table V). As described earlier by Rao et al., the initial rapid dissolution of the hydrophilic polymer occurs when the film is in contact with the hydrated skin, resulting in the accumulation of high amounts of drug in the skin surface, thus leading to saturation of the skin with drug molecules (45).

Table V Ex Vivo Permeation Kinetics of GRN Films

The calculated values of transdermal flux, permeation coefficient, and the enhancement ratio for the prepared films were found to increase linearly with increasing levels of the hydrophilic polymer, i.e., Methocel® E15 in the formulation. These parameters are commonly used to evaluate the functionality of transdermal preparations and to provide a better understanding of the mechanisms of transdermal absorption of drugs (12,23). Hydrophilic-matrix-based films in the presence of permeation enhancers are known to demonstrate higher values of transdermal flux, permeation coefficient, and enhancement ratio.

CONCLUSIONS

The influence of formulation variables such as permeation enhancers (terpenes), hydrophilic matrix former (Methocel® E15), and film formers (Eudragit® RL 100 and Eudragit® RS 100) on the quality and functionality of a transdermal film formulation was evaluated. Consistent with the previous findings, d-limonene was found to be the most efficient permeation enhancer among the tested terpenes. The composition ratio of the hydrophilic matrix former and the film-forming polymers influenced the physicochemical and functional characteristics of the prepared films. A transdermal film formulation, having the required quality and performance attributes, can be optimally designed by the use of an appropriate type and amount of the above ingredients. The study emphasizes the importance of the rational selection of a combination of excipients to achieve targeted dosage form functionality.