Abstract
In this work, devices have been fabricated as to be nuclear detector, from p-CdMnTe. Three devices were prepared: First planar detector with (Au) ohmic contact on both sides; Second as schottky type device of In-CdMnTe with (Au) ohmic contact on the back face; and thirdly metal oxide semiconductor (MOS) device for which the samples annealed under Oxygen flow for (2 h.) at 700 °C, this device (MOS) when connected to conventional nuclear spectroscopy gave reasonable but not high quality signals due to irradiating with 137Cs, 241Am and (137Cs + 241Am). Matlab- software based on numerical methods is used to analyze the data. Resolution through the Full Width at Half Maximum and the area under the peak and the error for this detector are presented.
Similar content being viewed by others
References
T Takahashi and S Watanabe IEEE Trans. Nucl. Sci. 48 950 (2001)
P J Sellin Nucl. Instrum. Methods A513 332 (2003)
G A Carini, A E Bolotnikov, G S Camarda and R B James Nucl. Instrum. Methods A579 120 (2007)
A Burger, K Chattopadhyay, H Chen, J N dap Olivier, M Triredi Xiaoy, W Kuteher Susan, R Chen and D Robert J. Cryst. Growth 198/199 872 (1999)
S Mitra, A Mandal, S Banerjee, A, Datta, S Bhattacharya, A Bose and D Chakravorty Indian J. Phys. 85 649 (2011)
P Dash, P Mallick, H Rath, B N Dash, A Tripathi, J Prakash, D K Avasthi, P V Satyam and N C Mishra Indian J. Phys. 84 1391 (2010)
M C Santosh Kumar and B Pradeep Indian J. Phys. 85 401 (2011)
A Mycielski, A Burger, M Sowinska, M Groza, A P Wojnar, B Witkowska, W Kaliszek and P Siffert Phys. Status Solidi, 2 1578 (2005)
M Witkowska-Bran, A Mycielski, D Kochanows, A J Szadlkowski and R B James Nucl. Sci. Sympo. Conf. Rec. IEEE 327 (2008).
K H Kim, V Carcelen, A E Bolotnikov, G S Camarda, R Gul, A Hossain, G Yang, Y G Cui and R B James J. Electron. Mater. 39 1015 (2010)
K H Kim, A E Bolotnikov, G S Camarda, A Hossain, R Gul, G Yang, Y G Cui, J Prochazka, J Franc, J Hong and R B James J. Appl. Phys. 109 113715 (2011)
K H Kim, H Cho Shin, H Suh Jong, J Hong and U Kim Sun IEEE Trans. Nucl. Sci. 56 858 (2009)
L A Najam PhD Thesis (University of Mosul, College of Science, Physics Department, Iraq) (2006)
A A Azooz Instrum. Exp. Tech. 54 364 (2011)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Najam, L.A., Jamil, N.Y. & Yousif, R.M. Fabrication of CdMnTe semiconductor as radiation detector. Indian J Phys 86, 267–272 (2012). https://doi.org/10.1007/s12648-012-0051-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12648-012-0051-0