The quality of harvested rainwater used for toilet flushing in a private house in the south-west of France was assessed over a one-year period. Twenty-one physicochemical parameters were screened using standard analytical techniques. The microbiological quality of stored roof runoff was also investigated and total flora at 22°C and 36°C, total coliforms, Escherichia Coli, enteroccocci, Cryptospridium oocysts, Giardia cysts, Legionella species, Legionella pneumophila, Aeromonas, and Pseudomonas aeruginosa were analysed. Chemical and microbiological parameters fluctuated during the course of the study, with the highest levels of microbiological contamination observed in roof runoffs collected during the summer. Overall, the collected rainwater had a relatively good physicochemical quality but variable, and, did not meet the requirements for drinking water and a microbiological contamination of the water was observed. The water balance of a 4-people standard family rainwater harvesting system was also calculated in this case study. The following parameters were calculated: rainfall, toilets flushing demand, mains water, rainwater used and water saving efficiency. The experimental water saving efficiency was calculated as 87%. The collection of rainwater from roofs, its storage and subsequent use for toilet flushing can save 42 m3 of potable water per year for the studied system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  • Aladenola O, Adeboye O (2010) Assessing the potential or rainwater harvesting. Water Resour Manag 24(10):2129–2137

    Article  Google Scholar 

  • Al-Khashman OA (2009) Chemical characteristics of rainwater collected at a western site of Jordan. Atmos Res 91(1):53–61

    Article  Google Scholar 

  • Albrechtsen HJ (2002) Microbiological investigations of rainwater and graywater collected for toilet flushing. Water Sci Technol 46(6–7):311–316

    Google Scholar 

  • Blangis D, Legube B (2007) Treatment of rain water by solar photocatalysis. Eur J Water Qual 38(2):121–130

    Article  Google Scholar 

  • Chilton JC, Maidment GG, Marriott D, Francis A, Tobias G (1999) Case study of a rainwater recovery system in a commercial building with a large roof. Urban Water 1:345–354

    Article  Google Scholar 

  • Crabtree KD, Ruskin RH, Shaw SB, Rose JB (1996) The detection of cryptosporidium oocysts and Giardia cysts in cistern water in the U.S. Virgin Islands. Water Res 30(1):208–216

    Article  Google Scholar 

  • Despins C, Farahbakhsh K, Leidl C (2009) Assessment of rainwater quality from rainwater harvesting systems in Ontario, Canada. J Water Supply Res Technol - Aqua 58(2):117–134

    Article  Google Scholar 

  • Evans CA, Coombes PJ, Dunstan RH (2006) Wind, rain and bacteria: the effect of weather on the microbial composition of roof-harvested rainwater. Water Res 40(1):37–44

    Article  Google Scholar 

  • Evans CA, Coombes PJ, Dunstan RH, Harrison T (2009) Extensive bacterial diversity indicates the potential operation of a dynamic micro-ecology within domestic rainwater storage systems. Sci Total Environ 407(19):5206–5215

    Article  Google Scholar 

  • Fewkes A (1999a) Modelling the performance ofrainwater collection systems: towards a generalised approach. Urban Water 1:323–333

    Article  Google Scholar 

  • Fewkes A (1999b) The use of rainwater for WC flushing: the field testing of a collection system. Build Environ 34:765–772

    Article  Google Scholar 

  • Fewtrell L, Kay D (2007) Microbial quality of rainwater supplies in developed countries: a review. Urban Water J 4(4):253–260

    Article  Google Scholar 

  • Förster J (1999) Variability of roof runoff quality. Water Sci Technol 39(5):137–144

    Article  Google Scholar 

  • Handia L (2005) Comparative study of rainwater quality in urban Zambia. J Water Supply Res Technol - Aqua 54(1):55–64

    Google Scholar 

  • Herrmann T, Schmida U (1999) Rainwater utilisation in Germany: efficiency, dimensioning, hydraulic and environmental aspects. Urban Water 1:307–316

    Article  Google Scholar 

  • Horak HM, Chynoweth JS, Myers WP, Davis J, Fendorf S, Boehm AB (2010) Microbial and metal water quality in rain catchments compared with traditional drinking water sources in the East Sepik Province, Papua New Guinea. J Water Health 8(1):126–138

    Article  Google Scholar 

  • Khastagir A, Jayasuriya N (2011) Investment evaluation of rainwater tanks. Water Resour Manag 25(14):3769–3784

    Article  Google Scholar 

  • Kulshrestha UC, Kulshrestha MJ, Sekar R, Sastry GSR, Vairamani M (2003) Chemical characteristics of rainwater at an urban site of south-central India. Atmos Environ 37(21):3019–3026

    Article  Google Scholar 

  • Lee JY, Yang JS, Han M, Choi J (2010) Comparison of the microbiological and chemical characterization of harvested rainwater and reservoir water as alternative water resources. Sci Total Environ 408(4):896–905

    Article  Google Scholar 

  • May S, Prado RTA (2006) Experimental evaluation of rainwater quality for non-potable applications in the city of Sao Paulo, Brazil. Urban Water J 3(3):145–151

    Article  Google Scholar 

  • Melidis P, Akratos CS, Tsihrintzis VA, Trikilidou E (2007) Characterization of rain and roof drainage water quality in Xanthi, Greece. Environ Monit Assess 127(1–3):15–27

    Article  Google Scholar 

  • Mendez CB, Klenzendorf JB, Afshar BR, Simmons MT, Barrett ME, Kinney KA, Kirisits MJ (2011) The effect of roofing material on the quality of harvested rainwater. Water Res 45(5):2049–2059

    Article  Google Scholar 

  • Nolde E (2007) Possibilities of rainwater utilisation in densely populated areas including precipitation runoffs from traffic surfaces. Desalination 215(1–3):1–11

    Article  Google Scholar 

  • Oesterholt F, Martijnse G, Medema G, van der Kooij D (2007) Health risk assessment of non-potable domestic water supplies in the Netherlands. J Water Supply Res Technol - Aqua 56(3):171–179

    Article  Google Scholar 

  • Polkowska Z, Gorecki T, Namiesnik J (2002) Quality of roof runoff waters from an urban region (Gdansk, Poland). Chemosphere 49(10):1275–1283

    Article  Google Scholar 

  • Sazakli E, Alexopoulos A, Leotsinidis M (2007) Rainwater harvesting, quality assessment and utilization in Kefalonia Island, Greece. Water Res 41(9):2039–2047

    Article  Google Scholar 

  • Schriewer A, Horn H, Helmreich B (2008) Time focused measurements of roof runoff quality. Corros Sci 50(2):384–391

    Article  Google Scholar 

  • Simmons G, Hope V, Lewis G, Whitmore J, Gao W (2001) Contamination of potable roof-collected rainwater in Auckland, New Zealand. Water Res 35(6):1518–1524

    Article  Google Scholar 

  • Tsakovski S, Tobiszewski M, Simeonov V, Polkowska Z, Namiesnik J (2010) Chemical composition of water from roofs in Gdansk, Poland. Environ Pollut 158(1):84–91

    Article  Google Scholar 

  • Uba BN, Aghogho O (2000) Rainwater quality from different roof catchments in the Port Harcourt district, rivers state, Nigeria. J Water Supply Res Technol - Aqua 49(5):281–288

    Google Scholar 

  • Villarreal EL, Dixon A (2005) Analysis of a rainwater collection system for domestic water supply in Ringdansen, Norrköping, Sweden. Build Environ 40:1174–1184

    Article  Google Scholar 

  • Zhang Y, Grant A, Sharma A, Chen D, Chen L (2010) Alternative water resources for rural residential development in Western Australia. Water Resour Manag 24(1):25–36

    Article  Google Scholar 

Download references

Acknowledgement

The authors would like to thank Sotralentz Habitat for their provision of rainwater-harvesting equipment and Laurent Monier (Veolia Eau, Saint-Maurice, France) for his technical support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to C. Vialle.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vialle, C., Sablayrolles, C., Lovera, M. et al. Water Quality Monitoring and Hydraulic Evaluation of a Household Roof Runoff Harvesting System in France. Water Resour Manage 26, 2233–2241 (2012). https://doi.org/10.1007/s11269-012-0012-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11269-012-0012-6

Keywords

Navigation