Abstract
A simple and sensitive method of gas chromatography–mass spectrometry for quantification of β-elemene in human plasma was developed and validated. An n-hexane-based liquid–liquid extraction assisted by saturated sodium chloride solution was used for sample preparation. Naphthalene was chosen as the internal standard. The calibration curve (r 2 = 0.9997) of β-elemene was established at the range of 0.0655–40.00 μg mL−1 and the lower limit of quantification (LLOQ) was 0.0655 μg mL−1 using 200 μL of plasma, respectively. The accuracy was in a range of 87.1–101.7 %, and intra- and inter-day precisions (RSD %) at three QC levels were all less than 10 %. The LLOQ of 0.0665 μg mL−1 is sensitive enough to perform pharmacokinetic studies after β-elemene administration.
References
Liu J, Zhang Y, Qu J, Xu L, Hou K, Zhang J, Qu X, Liu Y (2011) BMC Cancer 11:183
Li J, JunYu, Liu A, Wang Y (2014) Lung Cancer-J Iaslc
Yao YQ, Ding X, Jia YC, Huang CX, Wang YZ, Xu YH (2008) Cancer Lett 264:127–134
Guan C, Liu W, Yue Y, Jin H, Wang X, Wang XJ (2014) Int J Clin Exp Pathol 7:3948–3956
Tao L, Zhou L, Zheng L, Yao M (2006) Cancer Chemother Pharmacol 58:24–34
Zhao J, Li QQ, Zou B, Wang G, Li X, Kim JE, Cuff CF, Huang L, Reed E, Gardner K (2007) Int J Oncol 31:241–252
Han W, Sun J, Feng L, Wang K, Li D, Pan Q, Chen Y, Jin W, Wang X, Pan H, Jin H (2011) PLoS One 6:e28491
Zhang X, Li Y, Zhang Y, Song J, Wang Q, Zheng L, Liu D (2013) PLoS One 8:e58719
An YW, Hu G, Yin GP, Zhu JJ, Zhang QW, Wang ZM, Peng J, Fan B (2014) J Chromatogr Sci 52:961–970
Yang FQ, Wang YT, Li SP (2006) J Chromatogr A 1134:226–231
Wang K, Li Z, Chen Y, Su C (2005) Biopharm Drug Dispos 26:301–307
Wu L, Song X, Liu H, Wei H, Dong D, Wang X (2007) Chinese J Tradit Med Sci 6:425–426
Chen Z, Song Y, Che J, Liu X, Ning Y, Shan C, Hou Y, Liu Y, Miao X, Cheng Y (2009) J Chromatogr B Analyt Technol Biomed Life Sci 877:408–414
Zhang BJ, Li WC, Liu XP (2012) Zhong Yao Cai 35:1464–1468
Nikolaou P, Papoutsis I, Dona A, Spiliopoulou C, Athanaselis S (2015) J Pharm Biomed Anal 102:25–32
Acknowledgments
This work was supported by the National Natural Science Foundation of China (No. 81102499), Hunan Science and Technology Project (No. 2011SK3261) and the Fundamental Research Funds for the Central Universities of Central South University (No. 2014zzts313).
Author information
Authors and Affiliations
Corresponding authors
Additional information
S. Li and R. Zhou have contributed equally.
Rights and permissions
About this article
Cite this article
Li, S., Zhou, R., Mu, L. et al. A Sensitive GC–MS Method for the Determination of β-Elemene in Human Plasma. Chromatographia 78, 729–734 (2015). https://doi.org/10.1007/s10337-015-2875-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10337-015-2875-1