Introduction

Staphylococcus aureus presents a significant threat to human health as it is capable of causing a wide range spectrum of infections from minor skin conditions to life-threatening diseases, particularly in healthcare settings. According to a survey conducted in 2019, Staphylococcus aureus ranked first in global mortality rates among 33 bacterial pathogens [1]. This bacterium has developed resistance to multiple antibiotics, making it difficult to treat and increasing the risk of severe and prolonged infections. Initially, vancomycin was considered the last resort for treating multidrug-resistant Staphylococcus aureus (MRSA) [2]. However, the subsequent discovery of heterogeneous (hVISA) and vancomycin-intermediate Staphylococcus aureus (VISA) has posed new challenges in the clinical treatment of these pathogens [3]. Studies have shown that VISA/hVISA was associated with persistent infection, treatment failure, and prolonged hospital stays [4].

VISA/hVISA and vancomycin-resistant Staphylococcus aureus (VRSA) are collectively known as vancomycin-insensitive Staphylococcus aureus. In clinical practice, VRSA is rare, while VISA/hVISA is more commonly encountered. However, the main challenge for VISA/hVISA lies in its identification. hVISA consists of subpopulations with a frequency of 10− 4-10− 6, exhibiting varying levels of vancomycin-intermediate resistance. Standard antimicrobial susceptibility testing methods, such as the broth microdilution method (BMD) and agar dilution method (AD), utilize a two-fold dilution system, which may mistakenly classify hVISA as vancomycin-sensitive Staphylococcus aureus (VSSA). In addition, the disk diffusion method is not recommended by the Clinical and Laboratory Standards Institute (CLSI) as a screening method for vancomycin resistance due to the slow diffusion of vancomycin in the culture medium [5]. Different methods commonly used for detecting the minimum inhibitory concentration (MIC) of vancomycin also show variations. Etest results are twofold higher than broth microdilution (BMD) MIC results, while Vitek2 results are twofold lower than BMD MIC results [6]. When using the broth dilution method as the standard, Vitek Legacy and Vitek 2 systems tend to classify VISA strains as susceptible, while MicroScan and Phoenix systems, as well as Etest, tend to classify susceptible strains as VISA [7]. In conclusion, traditional drug sensitivity testing is not able to reliably identify hVISA/VISA.

Furthermore, the “gold standard” for hVISA/ VISA detection is population analysis profiling with area under the curve (PAP-AUC) [8]. However, this method is time-consuming and labor-intensive, making it unsuitable for routine clinical use.

The routine screening for hVISA/VISA is mainly conducted through phenotypic analysis using BHIA with different glycopeptides. Numerous studies made extensive use of BHI-V4 due to its affordability and ease of use. However, the diagnostic value of this screening plate remains unclear. To the best of our knowledge, there are few meta-analyses available regarding the screening methods for hVISA/VISA in English journals. As a result, it becomes necessary to summarize the reported findings, assess the available data, and attempt to identify research gaps that need to be filled.

Materials and methods

Search strategy

Relevant studies on VISA and hVISA published from inception to October 2023 were searched in PubMed, Embase, Cochrane Library and Web of Science using the following keywords: ‘vancomycin-intermediate Staphylococcus aureus’; ‘VISA’; ‘heterogeneous vancomycin-intermediate Staphylococcus aureus’; ‘hVISA’; ‘Staphylococcus aureus with reduced susceptibilities to vancomycin’; ‘VNSA’; ‘glycopeptide-intermediate Staphylococcus aureus’; ‘GISA’; ‘heterogeneous glycopeptide-intermediate Staphylococcus aureus’; ‘hGISA’. Figure 1 performs the search strategy outlined following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [9]. The systematic search conducted was not restricted to any specific study or publication type to ensure a thorough evaluation of the literature. Our protocol was registered on 18 December 2023 by INPLASY under registration number INPLASY2023120069 with the purpose of “diagnostic value of BHI-V4 for heterogeneous and vancomycin-intermediate Staphylococcus aureus isolates” [10].

Fig. 1
figure 1

Flow diagram showing the study selection process. WOS: Web of Science

Inclusion and exclusion criteria

Original studies that met the following criteria were included: (1) all experiments including BHI-V4 screening (The standard inoculum concentration and volume are 0.5McFarland and 10ul, respectively); (2) published papers; (3) reference method was PAP-AUC; (4) The indicators of true positive (TP), false positive (FP), false negative (FN), and true negative (TN) needed for the combined effect value could be derived directly or indirectly using the original study’s data.

Exclusion criteria included: (1) review, brief report, case report, letter, comment, or conference paper; (2) duplicate publications; (3) unable to retrieve full text; (4) non-English publications; (5) unable to obtain the TP, FP, FN, TN, and other data directly or indirectly, or the data is incorrect; (6) without PAP-AUC.

Study selection

Two reviewers (X.C. and J.Z.) autonomously evaluated titles, abstracts, and full-text papers. Discrepancies in the selection of studies were handled by engaging in discussions until an agreement was reached. If necessary, a third reviewer (F.Y., J.M., S.G., or J.S.) was consulted for further input. The eligibility of studies was evaluated based on the specified criteria for inclusion and exclusion.

Quality assessment and data extraction

Two reviewers (X.C. and J.Z.) conducted a quality assessment for each study using the QUADAS-2 tool, which is a method for evaluating the quality of diagnostic studies [11]. Review Manager 5.4 was utilized for data visualization in the quality assessment. The following data were extracted from the included studies: author, year, TP, FP, FN, TN, country, sample size, and phenotype, as well as study type.

Data analysis

STATA17.0 (MP) was utilized for statistical analysis. The effect sizes of diagnostic accuracy were pooled, which included sensitivity, specificity, diagnostic odds ratio (DOR), negative likelihood ratio, and positive likelihood ratio with their associated 95% confidence intervals (95%CIs). The SROC curves were employed to compute the AUC of the integrated model. The threshold heterogeneity of the included studies was assessed using Spearman’s correlation coefficient, and non-threshold heterogeneity was assessed using Cochran’s Q and I2 values. A random effects model was employed to integrate the data if the I2 value was greater than 50% or P < 0.05 which indicated significant heterogeneity. When the I2 value was less than 50% or P ≥ 0.05, a fixed effect model was chosen. Fagan nomogram was used to evaluate clinical utility. Deek’s funnel plot was used to examine the publication bias of the included studies. A P < 0.05 was deemed statistically significant.

Results

Search results and study characteristics

The study selection process is depicted in Fig. 1. A total of 1232 studies were yielded by our search approach, with 11 duplicates discarded, 1105 eliminated after titles and abstracts were screened, and 88 removed after full-text article reading. The remaining 28 potentially eligible studies were selected for further evaluation. Of these, 20 articles were excluded based on the exclusion criteria. Finally, a total of eight publications [12,13,14,15,16,17,18,19] were included in this meta-analysis.

The main characteristics of the included studies are briefly presented in Table 1. Of the eight studies, five were retrospective studies and three were prospective studies; half of the studies were conducted in America, whereas the other half were in India, Argentina, Brazil, and England; all studies were conducted during 2001–2017. In addition, the sample size ranged from 11 cases to 500 cases.

Table 1 The main characteristics of the included studies

Quality assessment

As indicated in Fig. 2, the general quality of the included literature was high. The gold standard, diagnostic criteria for hVISA/VISA, and demographic information were all described in all of the included investigations. However, none of the studies adopted a case-control design and it is unclear whether BHI-V4 was conducted at the same time as the reference standard. None of the studies was excluded based on the quality assessment.

Fig. 2
figure 2

Summary of risk of bias and applicability of concerns graph

Performance of BHI-V4 in diagnosing hVISA/VISA

Heterogeneity analysis

The Spearman’s correlation coefficient was − 0.70, and the proportion of heterogeneity likely due to the threshold effect was 0.48, suggesting that the threshold effect is negligible, thus permitting the combining of the effect sizes. Moreover, the results indicated high non-threshold heterogeneity (Q = 99.875, I2 = 98.95%); therefore, the effect sizes were combined using the random effects model.

Combined effect analysis

The SROC was 0.77 (95% CI, 0.74–0.81) (Fig. 3). The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic score, and diagnostic odds ratio were 0.59 (95% CI: 0.46–0.71), 0.96 (95%CI: 0.83–0.99), 14.0 (95% CI, 3.4–57.1), 0.43 (95%CI, 0.32–0.57), 3.48(95%CI, 2.12–4.85) and 32.62 (95%CI, 8.31-128.36), respectively (Fig. 4).

Fig. 3
figure 3

Summary receiver operating characteristic curves

Fig. 4
figure 4

Forest plot of sensitivity (A), specificity (B), positive likelihood ratio (C), negative likelihood ratio (D), diagnostic score (E) and diagnostic odds ratio (F) of BHI-V4

Fagan nomogram analysis

We evaluated the utility of BHI-V4 for diagnosing hVISA/VISA using the Fagan nomogram (Fig. 5). When the pre-test probability was set at 20%, the post-test probability was 78% for a positive result and 10% for a negative result. This indicates the good diagnostic value of BHI-V4 in clinical applications.

Fig. 5
figure 5

Fagan nomogram of the accuracy of BHI-V4

Publication bias

A Deek funnel plot (Fig. 6) was created to evaluate the presence of publication bias and there was no publication bias in the included studies for BHI-V4 in detecting hVISA/VISA (P = 0.31).

Fig. 6
figure 6

Deek funnel plot for publication bias

Discussion

The association between the presence of hVISA/VISA and suboptimal therapeutic outcomes with glycopeptide drugs has been extensively documented in the literature. However, conventional detection techniques often face challenges in accurately identifying these bacteria due to limitations in sensitivity, potentially leading to an underestimation of their actual prevalence [20]. A meta-analysis showed that the hVISA detection rate in the 99,042 MRSA strain was 6.05%, and the VISA detection rate in the 68,792 MRSA strain was 3.01% [21]. However, the prevalence of hVISA and VISA varies greatly in different literature reports. In routine practice, it is not feasible to employ gold-standard testing for all strains. Therefore, there is an urgent need to develop a simple and cost-effective screening method that can aid in early detection and prevent antibiotic overuse. Fortunately, BHI-V4 possesses all the aforementioned advantages. While the BHI-V4 method is commonly used as a screening tool, it is important to note that its reported sensitivity and specificity have varied across different research studies [12,13,14,15,16,17,18,19], and most studies lack statistical information. Hence, our research focuses on evaluating the diagnostic value of BHI-V4 for hVISA/VISA. To the best of our knowledge, this is the first review and meta-analysis on the diagnostic method for hVISA/VISA.

This study selected eight relevant works of literature from 1232 articles using PAP-AUC as the gold standard for screening hVISA/VISA with BHI-V4. The results showed a combined sensitivity of 0.59, indicating moderate sensitivity and suggesting a potential for missed diagnoses. The specificity was 0.96, indicating strong specificity. The positive likelihood ratio was 14.0, suggesting a low misdiagnosis rate, meaning that when BHI-V4 is positive, there is a high probability of suspected hVISA/VISA. The negative likelihood ratio was 0.43, indicating a relatively high rate of missed diagnosis with BHI-V4 negativity, meaning that the possibility of excluding hVISA is relatively low when BHI-V4 is negative. The SROC AUC was 0.77, indicating high diagnostic accuracy. By comparison, BHIA supplemented with 6 µg/mL of vancomycin (BHI-V6) had a specificity of 98.8% but a sensitivity of only 3.8% while BHIA supplemented with 5 µg/mL of teicoplanin (BHI-T5) has a sensitivity of 88.5% and a specificity of 17.3% [17]. Furthermore, Etest derivative techniques such as glycopeptide resistance detection and macro Etest method have been reported to exhibit a high level of specificity but a poor level of sensitivity [5, 17, 22, 23].

The heterogeneity test results indicate that there are statistically significant differences between different research findings, which may be related to the following factors. First, BHI-V4 itself has limitations and cannot effectively distinguish between hVISA and VISA. Some studies refer to hVISA as growth on medium after 24 h, and VISA as growth on medium after 24–48 h [3, 19, 24]. However, this rough identification result may differ from the gold standard identification result. It is well-known that VISA has a more pronounced phenotype that is easier to identify than hVISA. Hence, the proportion of hVISA /VISA will affect the detection efficiency. Second, both hVISA and VISA are unstable and can revert to a sensitive state under certain conditions [25]. Therefore, timely detection is crucial for hVISA/VISA. Unfortunately, the timeliness of detection was not mentioned in the studies. Third, sample sizes vary across studies, and small sample sizes can introduce biases into the results. Four articles had a strain count of fewer than 200 cases, and three studies even had a strain count below 100 cases. In addition, various factors during the experimental process, such as the quality of the testing materials like BHI and vancomycin, incubation conditions, the status of the strains, and the proficiency of the operators, can influence the detection rate. It is difficult to identify the causes of these heterogeneity results through subgroup analysis.

There are several limitations to this article. The main limitation of this meta-analysis is that only 8 studies were included, and the heterogeneity is high. Second, because the included papers are all published, publication bias must be considered, especially in meta-analysis research that depends on published studies of testable interventions [26]. Third, the diagnostic data for BHI-V4 in the included studies were estimated indirectly, and additional direct evidence is needed to determine BHI-V4’s diagnostic significance. However, because no publication bias was identified in this investigation, we assume that this bias should be minimal.

In conclusion, our study showed that BHI-V4 had moderate diagnostic accuracy for diagnosing hVISA/VISA based on the available data. Moreover, the advantages of excellent economic benefits and simple operation make this method suitable for clinical promotion. However, its low sensitivity increases the risk of false negatives or missed detections. In clinical practice, it is reasonable to combine other screening methods such as BHI-T5 to reduce the risk of missed detections. Furthermore, more high-quality studies are needed to assess the clinical utility of BHI-V4.