The superior diagnostic performance of positron emission tomography (PET) myocardial perfusion imaging (MPI) over single photon emission computed tomography (SPECT) MPI, the robust ability to quantify myocardial blood flow by PET and its lower radiation exposure, are leading to the increased adoption of PET for epicardial and microvascular coronary artery disease evaluation.1 This is further supported by the 2021 multisocietal guideline document for the evaluation and diagnosis of chest pain which provided a class I recommendation for MPI in intermediate-high risk patients with stable chest pain, and a class IIa recommendation for choosing PET over SPECT for MPI, when PET is available.2 In parallel, PET hardware has significantly evolved.3 PET cameras detect paired 511 keV photons, localized using the coincidence detection principle. However, given both photons must be detected, the entire path they travel and the signal attenuation induced by soft tissue must be accounted for and corrected, i.e., attenuation correction (AC) implemented. Historically, AC for PET was done by radionuclide (68Ge/68Ga PET or 137Cs SPECT) transmission rod sources circling around the patient to collect photon attenuation maps.4 These have since been replaced by computed tomography (CT)-based attenuation in contemporary scanners given faster data acquisition and lower noise attenuation maps, among other improvements, further compounded by the additive anatomic and diagnostic information provided by CT.5
Imaging findings during PET/CT MPI that are not (cardiac) perfusion-related can be divided into two categories: extracardiac radiotracer uptake, and cardiac and extracardiac CT findings. Societal documents recommend that all reports include a section detailing these findings.6 Indeed, there is a growing body of evidence underscoring the frequency and importance of these observations that require a systematic reading strategy by the interpreting physician as well as an understanding of clinical ramifications such as downstream testing.7
Evaluation of the extracardiac uptake of myocardial perfusion radiotracers necessitates a brief overview of their mechanisms of uptake (Figure 1). 15O-water is freely diffusible across plasma membranes and has a theoretical extraction fraction of 100%. 13N-ammonia also freely diffuses across the plasma membrane, gains a charge during that process to become 13N-ammonium, which in turn reacts with glutamate to become 13N-glutamine that remains trapped intracellularly. 82Rb-chloride is a K+ analog that predominantly requires active transport across the plasma membrane via the Na+/K+-ATPase pump to enter the cell. All these processes readily occur outside cardiomyocytes, laying the foundation for the extracardiac uptake and assessment of these perfusion radiotracers. Expansion of these observations to 18F-flurpiridaz, a novel PET perfusion radiotracer that has undergone phase III evaluation,8,9,10 is amenable to myocardial blood flow quantitation,11,12,13 and is being presented to regulatory bodies for adoption in clinical practice, will be of further interest. 18F-flurpiridaz has a very rapid uptake by cardiomyocytes and slow washout due to high binding affinity to mitochondrial complex-I (nicotinamide adenine dinucleotide [NADH]:ubiquinone oxidoreductase).14 Given the near ubiquitous presence of mitochondria in multicellular eukaryotic organisms – with the notable exception of erythrocytes – ‘foci’ of extracardiac uptake with this perfusion radiotracer, similar to 15O-water, 13N-ammonia, and 82Rb-chloride, are anticipated.
Although 13N-ammonia was the first PET radiotracer developed for MPI,15,16 it requires an on-site or very nearby cyclotron to be produced, limiting its widespread availability. In routine clinical practice, 82Rb-chloride is the predominant PET MPI radiotracer used, in large part due to its on-site availability from generators where it is eluted from its parent compound 82Sr. Whereas 15O-water is used in Europe for PET/CT MPI, it is not approved by the U.S. Food and Drug Administration for clinical use.
In the present study by Jochumsen et al. published in the Journal of Nuclear Cardiology,17 the authors determined the frequency and nature of extracardiac findings associated with 15O-water uptake as observed during 15O-water PET/CT MPI (Figure 2). All patients were scanned at rest and during pharmacologically induced hyperemia with a 6-min infusion of adenosine (0.14 mg/kg/min). The scans were 4-min dynamic acquisitions, initiated at the same time as the infusion of 400 MBq 15O-water. The investigators evaluated n = 2963 consecutive patients using reports generated during clinical reads with summed PET images (as opposed to parametric images) in a single center. 13% of the reports indicated coincidental findings, of which appr. 1/3 were considered benign, 1/3 unchanged lung nodules, and 1/4 potential malignancies. Of note, potential malignancies were categorized as 86% new/unknown lung nodules or ground glass opacities, 9% highly suspicious of malignancy, and 3% enlarged lymph nodes. Importantly, in nearly all cases, extracardiac PET radiotracer uptake was corroborated by the attenuation CT scan, highlighting further the importance of hybrid imaging. The sole ‘discrepant’ case was due to differences in field of view between PET and CT.
Malignant lesions that were detected with increased 15O-water uptake included lung cancer, lymphomas, breast cancer, and metastases of abdominal tumors. Non-malignant pathologies included lung findings such as pneumonia and fibrosis, pleural plaques, as well as sarcoidosis and rib fractures. The authors note that with few exceptions, the extracardiac uptake of 15O-water was identical between rest and adenosine stress. Overall, these findings led to downstream testing in 4% of patients, most often a high-resolution CT scan as first line, and in some cases biopsy and/or 18F-FDG PET/CT evaluation.
Previous studies analyzed the prevalence of extracardiac findings observed during 13N-ammonia and 82Rb-chloride PET/CT MPI, derived for the most part from the CT attenuation scans (Table 1). Kan et al.18 reported their experience with 13N-ammonia PET/CT in n = 1397 patients. Extracardiac findings were detected on low-dose attenuation CT. Clinically relevant / potentially relevant findings included lung nodules, enlarged lymph nodes, malignancies, and metastatic lesions. This study is noteworthy due to its significant proportion of females (47% of the study population). Mirpour et al.19 included n = 406 patients who underwent 82Rb-chloride PET/CT MPI, and observed n = 67 incidental findings. Of those, n = 8 were malignant. He et al.20 completed the largest case series analyzing attenuation CT scans in 82Rb-chloride PET/CT MPI in the veteran population; 96.2% were male, and 72.9% had a history of smoking. Of the n = 771 patients that were analyzed, n = 378 patients (49%) had incidental findings when interpreted by the radiologist, with the most common findings being pulmonary nodules and aortic aneurysms.
Whether the following parameters may affect the prevalence of extracardiac radiotracer uptake, and the characteristics of associated findings, will require further evaluation: positron range, radiotracer half-life, myocardial extraction fraction, rest vs. stress image acquisition, exercise vs. pharmacological stress, and finally the type and protocol of pharmacological stress.21,22,23,24,25 On the other hand, CT-based extracardiac findings observed in PET/CT MPI will be similar regardless of the radiotracer used, and more dependent on the hardware and image acquisition techniques, including mA (rate at which electrons flow through the X-ray tube and X-rays are produced) x time, kV (energy of the X-rays), gantry rotation time, pitch, slice thickness, and field of view.
The article by Jochumsen et al. expands our understanding of extracardiac and incidental PET/CT MPI findings by providing the first observations with 15O-water, and is thus an important addition to this field. Future studies should seek to systematically compare findings in PET/CT MPI with (i) extracardiac 18F-FDG uptake to assess inflammatory and/or malignant processes that may be detected by the PET MPI radiotracer, (ii) high-resolution CT to determine the accuracy of cardiac and extracardiac CT findings observed during PET/CT MPI, and (iii) in a subset of patients – ideally – validation against the reference standard of tissue biopsy. Finally, machine learning to improve the quality of CT transmission scans may further enhance diagnostic accuracy when assessing extracardiac findings.
As our knowledge in this field continues to grow, nuclear cardiology interpreting physicians should be aware of the possibility of these findings, understand their potential significance, seek additional input as needed, and be well-versed in the interpretation of diagnostic observations outside of PET MPI.7
References
Maddahi J, Packard RRS. PET should replace SPECT in cardiac imaging for diagnosis and risk assessment of patients with known or suspected CAD. J Nucl Cardiol 2017;24:1955‐9.
Gulati M, Levy PD, Mukherjee D, Amsterdam E, Bhatt DL, Birtcher KK, et al. 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR Guideline for the Evaluation and Diagnosis of Chest Pain: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation 2021;144:e368‐454.
Aide N, Lasnon C, Desmonts C, Armstrong IS, Walker MD, McGowan DR. Advances in PET/CT Technology: An Update. Semin Nucl Med 2022;52:286‐301.
Zaidi H. Is radionuclide transmission scanning obsolete for dual-modality PET/CT systems? Eur J Nucl Med Mol Imaging 2007;34:815‐8.
Slomka PJ, Pan T, Germano G. Recent Advances and Future Progress in PET Instrumentation. Semin Nucl Med 2016;46:5‐19.
Tilkemeier PL, Bourque J, Doukky R, Sanghani R, Weinberg RL. ASNC imaging guidelines for nuclear cardiology procedures: Standardized reporting of nuclear cardiology procedures. J Nucl Cardiol 2017;24:2064‐128.
Al-Mallah MH, Bateman TM, Branch KR, Crean A, Gingold EL, Thompson RC, et al. 2022 ASNC/AAPM/SCCT/SNMMI guideline for the use of CT in hybrid nuclear/CT cardiac imaging. J Nucl Cardiol 2022;29:3491‐535.
Maddahi J, Lazewatsky J, Udelson JE, Berman DS, Beanlands RSB, Heller GV, et al. Phase-III Clinical Trial of Fluorine-18 Flurpiridaz Positron Emission Tomography for Evaluation of Coronary Artery Disease. J Am Coll Cardiol 2020;76:391‐401.
Packard RRS, Lazewatsky JL, Orlandi C, Maddahi J. Diagnostic Performance of PET Versus SPECT Myocardial Perfusion Imaging in Patients with Smaller Left Ventricles: A Substudy of the (18)F-Flurpiridaz Phase III Clinical Trial. J Nucl Med 2021;62:849‐54.
Bourque JM, Hanson CA, Agostini D, Bateman TM, Bax JJ, Beanlands RSB, et al. Assessing myocardial perfusion in suspected coronary artery disease: rationale and design of the second phase 3, open-label multi-center study of flurpiridaz (F-18) injection for positron emission tomography (PET) imaging. J Nucl Cardiol 2021;28:1105‐16.
Packard RRS, Huang SC, Dahlbom M, Czernin J, Maddahi J. Absolute quantitation of myocardial blood flow in human subjects with or without myocardial ischemia using dynamic flurpiridaz F 18 PET. J Nucl Med 2014;55:1438‐44.
Moody JB, Poitrasson-Riviere A, Hagio T, Buckley C, Weinberg RL, Corbett JR, et al. Added value of myocardial blood flow using (18)F-flurpiridaz PET to diagnose coronary artery disease: The flurpiridaz 301 trial. J Nucl Cardiol 2021;28:2313‐29.
Packard RRS, Votaw JR, Cooke CD, Van Train KF, Garcia EV, Maddahi J. 18F-flurpiridaz positron emission tomography segmental and territory myocardial blood flow metrics: incremental value beyond perfusion for coronary artery disease categorization. Eur Heart J Cardiovasc Imaging 2022;23:1636‐44.
Yalamanchili P, Wexler E, Hayes M, Yu M, Bozek J, Kagan M, et al. Mechanism of uptake and retention of F-18 BMS-747158-02 in cardiomyocytes: a novel PET myocardial imaging agent. J Nucl Cardiol 2007;14:782‐8.
Gould KL, Schelbert HR, Phelps ME, Hoffman EJ. Noninvasive assessment of coronary stenoses with myocardial perfusion imaging during pharmacologic coronary vasodilatation. V. Detection of 47 percent diameter coronary stenosis with intravenous nitrogen-13 ammonia and emission-computed tomography in intact dogs. Am J Cardiol 1979;43:200‐8.
Schelbert HR, Wisenberg G, Phelps ME, Gould KL, Henze E, Hoffman EJ, et al. Noninvasive assessment of coronary stenoses by myocardial imaging during pharmacologic coronary vasodilation VI Detection of coronary artery disease in human beings with intravenous N-13 ammonia and positron computed tomography. Am J Cardiol 1982;49:1197‐207.
Jochumsen MR, Overgaard DL, Vendelbo MH, Madsen MA, Tolbod LP, Gormsen LC, et al. Extracardiac findings with increased perfusion during clinical O-15-H(2)O PET/CT myocardial perfusion imaging: A case series. J Nucl Cardiol 2023. https://doi.org/10.1007/s12350-022-03156-5.
Kan H, van der Zant FM, Wondergem M, Knol RJJ. Incidental extra-cardiac findings on (13)N-ammonia myocardial perfusion PET/CT. J Nucl Cardiol 2017;24:1860‐8.
Mirpour S, Khandani AH. Extracardiac abnormalities on rubidium-82 cardiac positron emission tomography/computed tomography. Nucl Med Commun 2011;32:260‐4.
He BJ, Malm BJ, Carino M, Sadeghi MM. Prevalence and variability in reporting of clinically actionable incidental findings on attenuation-correction CT scans in a veteran population. J Nucl Cardiol 2019;26:1688‐93.
Maddahi J, Packard RRS. Cardiac PET perfusion tracers: current status and future directions. Semin Nucl Med 2014;44:333‐43.
Wyss CA, Koepfli P, Mikolajczyk K, Burger C, von Schulthess GK, Kaufmann PA. Bicycle exercise stress in PET for assessment of coronary flow reserve: repeatability and comparison with adenosine stress. J Nucl Med 2003;44:146‐54.
Chow BJ, Beanlands RS, Lee A, DaSilva JN, deKemp RA, Alkahtani A, et al. Treadmill exercise produces larger perfusion defects than dipyridamole stress N-13 ammonia positron emission tomography. J Am Coll Cardiol 2006;47:411‐6.
Knaapen P. Optimal vasodilation protocols: The devil is in the details. Circ Cardiovasc Imaging 2017;10:e006035.
Packard RRS. Dipyridamole infusion protocols for absolute myocardial blood flow quantitation by PET. J Nucl Cardiol 2020;27:1829‐31.
Oldan JD, Femi-Abodunde AD, Muhleman MA, Khandani AH. Rubidium Uptake in Chest Tumors on PET/CT. World J Nucl Med 2022;21:18‐27.
Acknowledgements
The figures were created with BioRender.com.
Funding
Dr. Packard is supported by NIH R56HL158569, VA Merit BX004558, UCLA Cardiovascular Discovery Fund/Lauren B. Leichtman and Arthur E. Levine Investigator Award, and NIH NCATS UCLA CTSI UL1TR001881.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Disclosures
None.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
See related article, https://doi.org/10.1007/s12350-022-03156-5.
Rights and permissions
About this article
Cite this article
David, S., Packard, R.R.S. Prevalence and nature of extracardiac findings in PET/CT myocardial perfusion imaging. J. Nucl. Cardiol. 30, 1469–1473 (2023). https://doi.org/10.1007/s12350-023-03239-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12350-023-03239-x