Skip to main content
Log in

Zio® XT Patches in Pediatrics During the COVID-19 Pandemic: Comparisons Between In-Person and Mail-Home Application

  • Research
  • Published:
Pediatric Cardiology Aims and scope Submit manuscript

Abstract

The Zio® (Zio) XT Patch is a 14-day continuous ambulatory ECG monitor. During the Covid-19 pandemic, Zios were mailed directly to patients for self-application. The purpose of this study was to compare the percent artifact, a marker for quality, of in-clinic (IC) to mail-home (MH) applications in a pediatric population. A single-center, IRB-approved study of patients 0– < 21 years of age with Zios was studied for wear and artifact time filtered out based on iRhythm’s proprietary algorithm. In total, 284 Zios were randomly selected and analyzed for total wear time and artifact. Of these, 149 were IC prior to 12/31/2019 and 135 MH patches prescribed after 1/1/2020. No significant difference was found for percent artifact between the IC (7.8%) and MH (8.3%) group. Average IC wear-time was 127 h compared to MH at 99 h (p = 0.02). In conclusion, application of Zio patches outside of the pediatric cardiology clinic offers equivalent artifact, a marker of quality, as those applied in clinic and should be consideration as a viable alternative.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Barold SS (2003) Willem Einthoven and the birth of clinical electrocardiography a 100 years ago. Card Electrophysiol Rev 7(1):99–104

    Article  PubMed  Google Scholar 

  2. Rivera-Ruiz M, Cajavilca C, Varon J (2008) Einthoven’s string galvanometer: the first electrocardiograph. Tex Heart Inst J 35(2):174–178

    PubMed  PubMed Central  Google Scholar 

  3. Zimetbaum P, Goldman A (2010) Ambulatory arrhythmia monitoring: choosing the right device. Circulation 122(16):1629–1636

    Article  PubMed  Google Scholar 

  4. Bolourchi M, Silver ES, Muwanga D, Mendez E, Liberman L (2020) Comparison of Holter with zio patch electrocardiography monitoring in children. Am J Cardiol 125(5):767–771

    Article  PubMed  Google Scholar 

  5. Pradhan S, Robinson JA, Shivapour JK, Snyder CS (2019) Ambulatory arrhythmia detection with ZIO® XT Patch in pediatric patients: a comparison of devices. Pediatr Cardiol 40(5):921–924

    Article  PubMed  Google Scholar 

  6. Barrett PM, Komatireddy R, Haaser S, Topol S, Sheard J, Encinas J, Fought AJ, Topol EJ (2014) Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am J Med 127(1):95.e11-95.e17

    Article  PubMed  Google Scholar 

  7. Yenikomshian M et al (2019) Cardiac arrhythmia detection outcomes among patient monitored with the Zio patch system: a systematic literature review. Curr Med Res Opin 35(10):1659–1670

    Article  PubMed  Google Scholar 

  8. Benjamin H, Bischof M, Goldshtein D, Fecteau P, Newman D. A pandemic response to home delivery for ambulatory ECG monitoring: Development and validation. Published online November 18, 2020. J Electrocardiol.

  9. Muddassir Z, Padmadas H, Khan S, Krishnathasan K (2021) Home fitting of electrocardiogram (ECG) ambulatory monitors during covid-19. EP Europace. https://doi.org/10.1093/europace/euab116.026

    Article  Google Scholar 

  10. Hitt JR, Carter E, May J (2021) Patch versus traditional ambulatory ECG monitoring in children. Prog Pediatr Cardiol. https://doi.org/10.1016/j.ppedcard.2021.101408

    Article  Google Scholar 

Download references

Acknowledgements

In memoriam, Angela Dawson.

Funding

There was no funding provided to the authors for the conduction of this study.

Author information

Authors and Affiliations

Authors

Contributions

MK wrote the entire manuscript and prepared the figures and tables. GR performed the statistical analyses. AD provided all the Zio data from pediatric electrophysiology department at Rainbow Babies & Children's Hospital. CS conceptualized the project. All authors reviewed the manuscript. AD reviewed the initial draft of the manuscript (without figures and tables), prior to her untimely passing.

Corresponding author

Correspondence to Christopher Snyder.

Ethics declarations

Conflict of interest

The authors have no conflicts of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Khan, M.S., Dawson, A.Y. & Snyder, C. Zio® XT Patches in Pediatrics During the COVID-19 Pandemic: Comparisons Between In-Person and Mail-Home Application. Pediatr Cardiol (2023). https://doi.org/10.1007/s00246-023-03354-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s00246-023-03354-z

Keywords

Navigation